← Back
Three families
214 8 AVENUE
BROOKLYN · BIN 3025204
💬 Discuss this project
1894Year Built
3Stories
C0Building Class
R7BZoning
4,520 sfGross Floor Area
3Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Three families · Owner of record: SATATA NEW YORK LLC · 2,000 sf lot · 2.26 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Floor 11p · 1 filing · 12 docs
Sub-Basement1p · 1 filing · 12 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SATATA NEW YORK LLC1307/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/14/2022$3.9M—Private party → SATATA NEW YORK LLC$852/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
P GEORGOPOULOS ARCHITECT PC212/28/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TALL BUILDERS LLCGeneral Contractor303/21/2026
IRWIN FRIEDMAN & SON INCPlumbing207/08/2026
SDS LEONARD LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
P GEORGOPOULOS ARCHITECT889212/28/2022
Building Lifecycle
All (38)Filed (2)Permit Issued (4)Signed Off (1)Violation (4)Inspection (4)Objection (16)Special Inspection (7)
01/16/2024
Signed off — Alteration
FILING PLUMBING WORK UNDER INTERIOR RENOVATION APPLICATION JOB# B00769580. NO CHANGE TO USE, EGRESS AND OCCUPANCY.
B00769580-S1
11/17/2023
Permit issued — Structural
B00769580-I1-GC-CX
10/04/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
10/03/2023
Permit issued — Plumbing
B00769580-S1-PL
08/17/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/24/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
06/22/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
06/05/2023
Permit issued — Plumbing
B00769580-S1-PL
02/09/2023
Violation issued (ECB, closed)
Unknown
02/09/2023
Violation issued (ECB, closed)
Unknown
02/09/2023
Violation issued (ECB, closed)
Unknown
02/09/2023
Violation issued (ECB, closed)
Construction
12/28/2022
Filed — Alteration
FILING PLUMBING WORK UNDER INTERIOR RENOVATION APPLICATION JOB# B00769580. NO CHANGE TO USE, EGRESS AND OCCUPANCY.
B00769580-S1
12/28/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Vasilios Georgopoulos
12/26/2022
Special inspection requirement — Tenant Protection Plan Compliance
Vasilios Georgopoulos
12/12/2022
Permit issued — General Construction
B00769580-I1-GC-CX
10/14/2022
Objection resolved — Addressed
10/14/2022
Objection resolved — Addressed
10/03/2022
Objection raised — Zoning
09/28/2022
Objection raised — Scope
09/28/2022
Objection resolved — Addressed
09/28/2022
Objection resolved — Addressed
09/18/2022
Objection resolved — Addressed
09/18/2022
Special inspection requirement — Fire-Resistance Rated Construction
Vasilios Georgopoulos
09/16/2022
Objection resolved — Addressed
09/16/2022
Objection resolved — Addressed
09/16/2022
Objection resolved — Addressed
08/11/2022
Objection raised — Admin
08/11/2022
Objection raised — Zoning
08/11/2022
Objection raised — Admin
08/11/2022
Objection raised — Mechanical
08/11/2022
Objection raised — Scope
08/11/2022
Objection raised — Inspections
07/28/2022
Filed — Alteration
FILING PLUMBING WORK UNDER INTERIOR RENOVATION APPLICATION JOB# B00769580. NO CHANGE TO USE, EGRESS AND OCCUPANCY.
B00769580-I1
07/06/2022
Special inspection requirement — Final
Vasilios Georgopoulos
07/06/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Vasilios Georgopoulos
07/06/2022
Special inspection requirement — Mechanical Systems
Vasilios Georgopoulos
07/06/2022
Special inspection requirement — Structural Steel - High Strength Bolting
Vasilios Georgopoulos
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedTALL BUILDERS LLC11/17/2023
DOB NOWPlumbingSigned-offIRWIN FRIEDMAN & SON INC10/03/2023
DOB NOWPlumbingSigned-offIRWIN FRIEDMAN & SON INC06/05/2023
DOB NOWGeneral ConstructionPermit IssuedSDS LEONARD LLC12/12/2022
1 project · most recent 12/28/2022
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
12/28/2022Permit IssuedTALL BUILDERS LLCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric Mitsubishi MXZ-SM48NAM-U1 48,000 BTU · Heat Pump Outdoor ×2
1 project · most recent 12/28/2022
Gas Water/Sanitary
FiledStatusContractorScope
12/28/2022Signed-offIRWIN FRIEDMAN & SON INCGas, Water/Sanitary
2 projects · most recent 03/21/2023
General Wiring
FiledStatusContractorScope
03/21/2023Permit IssuedK.N.C ELECTRIC INCGeneral Wiring
02/10/2023Permit IssuedK.N.C ELECTRIC INCGeneral Wiring
1 project · most recent 12/28/2022
Wood
FiledStatusContractorScope
12/28/2022Permit IssuedTALL BUILDERS LLCWood
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
10/04/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
08/17/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/24/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
06/22/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
12/28/2022Fire-Resistant Penetrations and JointsVasilios Georgopoulosspecial
12/26/2022Tenant Protection Plan ComplianceVasilios Georgopoulosspecial
09/18/2022Fire-Resistance Rated ConstructionVasilios Georgopoulosprogress
07/06/2022FinalVasilios Georgopoulosprogress
07/06/2022Structural Stability – Alterations of existing buildingsVasilios Georgopoulosspecial
07/06/2022Mechanical SystemsVasilios Georgopoulosspecial
07/06/2022Structural Steel - High Strength BoltingVasilios Georgopoulosspecial
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/28/2026B00769580-S1Request digital key ↗
08/28/2026B00769580-I1Request digital key ↗
▸Applications & Permits2
▸DOB NOWLPC Approval/Permit2
08/13/2026B00769580-I1Open ↗
08/13/2026B00769580-S1Open ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026B00769580-S1Open ↗
08/13/2026B00769580-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/22/2026B00769580-I1Open ↗
08/22/2026B00769580-S1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/22/2026B00769580-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026B00769580-I1Open ↗
08/13/2026B00769580-S1Open ↗
▸Other Documents1
▸DOB NOWProof of Historic Building1
08/13/2026B00769580-I1Open ↗