← Back
BRONX
214 EAST 135 STREET
BRONX · Mott Haven-Port Morris · BIN 2826081
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
0 Open Violations
Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction7p · 2 filings · 20 docs
Floor 3Under Construction6p · 2 filings · 20 docs
Floor 2Under Construction6p · 2 filings · 20 docs
Floor 1Under Construction6p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
200 EAST 135TH STREET803/21/2026
200 E 135 ST LLC703/21/2026
200 EAST103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KEMS ENGINEERING AND CONSTRUCTION502/22/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LEWSAN CONSULTING1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NULITE FUEL OIL CO LTDPlumbing507/09/2026
NULITE FUEL OIL CO., LTDGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CL ENGINEERING P.C.6781202/22/2023
Building Lifecycle
All (39)Filed (5)Permit Issued (6)Signed Off (1)Violation (18)Special Inspection (9)
07/07/2026
Permit issued — Plumbing
X00799028-I1-PL
07/22/2025
Permit issued — Plumbing
X00799028-I1-PL
08/20/2024
Permit issued — Plumbing
X00799028-I1-PL
09/19/2023
Permit issued — Plumbing
X00799028-I1-PL
03/13/2023
Signed off — Alteration
Direct replacement of fifteen (15) split HVAC systems.
X00799024-I1
02/22/2023
Filed — Alteration
Direct replacement of fifteen (15) split HVAC systems.
X00799024-P1
02/22/2023
Filed — Alteration
Reconnection gas to direct replacement of fifteen (15) split HVAC systems.
X00799028-P2
02/22/2023
Special inspection requirement — Energy Code Compliance Inspections
Steven Bendoraitis
02/21/2023
Special inspection requirement — Mechanical Systems
CHRISTIAN LOZADA
02/21/2023
Special inspection requirement — Energy Code Compliance Inspections
Steven Bendoraitis
02/21/2023
Special inspection requirement — Final
Steven Bendoraitis
02/21/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Steven Bendoraitis
02/21/2023
Special inspection requirement — Maintenance information
Steven Bendoraitis
02/21/2023
Special inspection requirement — HVAC-R and service water heating equipment
Steven Bendoraitis
02/21/2023
Special inspection requirement — HVAC-R and service water heating system controls
Steven Bendoraitis
02/21/2023
Special inspection requirement — Energy Code Compliance Inspections
Steven Bendoraitis
11/03/2022
Filed — Alteration
Reconnection gas to direct replacement of fifteen (15) split HVAC systems.
X00799028-P1
10/17/2022
Permit issued — Mechanical Systems
X00799024-I1-MS
10/17/2022
Permit issued — Plumbing
X00799028-I1-PL
10/10/2022
Filed — Alteration
Direct replacement of fifteen (15) split HVAC systems.
X00799024-I1
10/10/2022
Filed — Alteration
Reconnection gas to direct replacement of fifteen (15) split HVAC systems.
X00799028-I1
01/29/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
06/01/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/01/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/15/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/15/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/04/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/04/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/17/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/17/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/18/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/18/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
12/14/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
12/14/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
11/01/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
11/01/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
07/26/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/21/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/17/2002
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedNULITE FUEL OIL CO LTD07/07/2026
DOB NOWPlumbingPermit IssuedNULITE FUEL OIL CO LTD07/22/2025
DOB NOWPlumbingPermit IssuedNULITE FUEL OIL CO LTD08/20/2024
DOB NOWPlumbingPermit IssuedNULITE FUEL OIL CO LTD09/19/2023
DOB NOWMechanical SystemsSigned-offNULITE FUEL OIL CO., LTD10/17/2022
DOB NOWPlumbingPermit IssuedNULITE FUEL OIL CO LTD10/17/2022
BIS—ISSUEDTRU-ART SIGN CO. INC03/05/2013
BIS—ISSUEDTRU-ART SIGN CO. INC03/05/2013
BIS—ISSUEDTRU-ART SIGN CO. INC03/05/2013
BIS—ISSUEDSTORAGE CONSTRUCTION CO.05/18/2012
BIS—ISSUEDNEW YORK SIGN CITY05/14/2003
BIS—ISSUEDNEW YORK SIGN CITY05/14/2003
BIS—ISSUEDNEW YORK SIGN CITY INC.05/13/2003
BISSDISSUEDMAIN CONNECTION OF NEW YORK,INC11/21/2002
BISSPISSUEDMAIN CONNECTION OF NEW YORK11/21/2002
BIS—ISSUEDRED HOOK CONSTRUCTION CORP I LLC04/15/2002
1 project · most recent 02/22/2023
Gas
FiledStatusContractorScope
02/22/2023Permit IssuedNULITE FUEL OIL CO LTDGas
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
02/22/2023Energy Code Compliance InspectionsSteven Bendoraitisprogress
02/21/2023Mechanical SystemsCHRISTIAN LOZADAspecial
02/21/2023Energy Code Compliance InspectionsSteven Bendoraitisprogress
02/21/2023FinalSteven Bendoraitisprogress
02/21/2023HVAC-R and service water piping design and insulationSteven Bendoraitisenergy_progress
02/21/2023Maintenance informationSteven Bendoraitisenergy_progress
02/21/2023HVAC-R and service water heating equipmentSteven Bendoraitisenergy_progress
02/21/2023HVAC-R and service water heating system controlsSteven Bendoraitisenergy_progress
02/21/2023Energy Code Compliance InspectionsSteven Bendoraitisprogress
▾Documents — 94 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/23/2026X00799028-I1Request digital key ↗
08/23/2026X00799028-P2Request digital key ↗
08/23/2026X00799028-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits13
▸BISPLAN / WORK APPROVAL APPLICATION8
12/18/2012220237312Open ↗
12/18/2012220237303Open ↗
12/17/2012220243591Open ↗
Showing 3 of 8 on file for this type
▸BISWORK PERMIT APPLICATION4
03/05/2013220243591Open ↗
03/05/2013220237303Open ↗
03/05/2013220237312Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
05/24/2012220132746Open ↗
▸Seals & Professional Certifications29
▸DOB NOWProgress Inspector Seal & Signature8
08/29/2026X00799028-P2Open ↗
08/26/2026X00799024-P1Open ↗
08/26/2026X00799024-P1Open ↗
Showing 3 of 8 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION6
03/26/2014220237312Open ↗
03/26/2014220237303Open ↗
03/26/2014220243591Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST5
12/18/2012220237312Open ↗
12/18/2012220237303Open ↗
12/17/2012220243591Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/23/2026X00799028-I1Open ↗
08/23/2026X00799028-P2Open ↗
08/23/2026X00799028-P1Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM4
12/18/2012220237312Open ↗
12/18/2012220237303Open ↗
12/17/2012220243591Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026X00799024-P1Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
08/06/2011220132746Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/23/2026X00799028-P1Open ↗
08/23/2026X00799028-P2Open ↗
08/23/2026X00799028-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWOER: Notice of Satisfaction2
08/13/2026X00799028-I1Open ↗
08/13/2026X00799024-I1Open ↗
▸DOB NOWOER: Notice to Proceed2
08/13/2026X00799024-I1Open ↗
08/13/2026X00799028-I1Open ↗
▸Energy Compliance1
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026X00799024-I1Open ↗
▸Approvals, Objections & Sign-offs17
▸BISLETTERS - SUPPORTING DOCUMENTATION5
03/26/2014220237312Open ↗
03/26/2014220237303Open ↗
07/15/2013220243591Open ↗
Showing 3 of 5 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST5
03/26/2014220237312Open ↗
03/26/2014220237303Open ↗
03/26/2014220243591Open ↗
Showing 3 of 5 on file for this type
▸BISADMINISTRATIVE OBJECTIONS4
12/18/2012220237312Open ↗
12/18/2012220237303Open ↗
12/17/2012220243591Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE3
05/11/2012220132746Open ↗
01/05/2012220132746Open ↗
08/06/2011220132746Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT6
03/26/2014220237312Open ↗
03/26/2014220237303Open ↗
03/26/2014220243591Open ↗
Showing 3 of 6 on file for this type
▸Filing & Intake Forms5
▸BISEFILING COVER SHEET4
12/18/2012220237312Open ↗
12/18/2012220237303Open ↗
12/17/2012220243591Open ↗
Showing 3 of 4 on file for this type
▸BISADDITIONAL INFORMATION1
07/31/2012220132746Open ↗
▸Other Documents8
▸BISENVIRONMENTAL 'E' DEP NOTICE TO PROCEED4
01/15/2013220243591Open ↗
01/15/2013220237312Open ↗
01/15/2013220237303Open ↗
Showing 3 of 4 on file for this type
▸BISENVIRONMENTAL -E- DEP NOTICE OF SATIS3
01/16/2013220243591Open ↗
01/16/2013220237303Open ↗
06/08/2012220132746Open ↗
▸BISPLOT DIAGRAM1
08/06/2011220132746Open ↗