← Back
Three families
2148 MULINER AVENUE
BRONX · BIN 2049479
💬 Discuss this project
1940Year Built
2Stories
C0Building Class
R6Zoning
4,896 sfGross Floor Area
3Units
Rent Stabilized10 Open Violations ▸
Three families · Owner of record: 2148 HOLDING LLC · 3,300 sf lot · 1.48 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalGeneral
Roof4p · 1 filing · 20 docs
Floor 24p · 1 filing · 20 docs
Floor 14p · 1 filing · 20 docs
Basement7p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
2148 HOLDING LLC203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/28/2023$915K—— → —$187/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AG ENGINEERING PLLC103/26/2026
NIKOLAI KATZ ARCHITECT508/06/2025
CHOSEN MEP, CORP.208/03/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPRESS FILING INC1403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MABE GROUP INCGeneral Contractor503/21/2026
AMOK INCFire Protection107/08/2026
YNR CONSTRUCTION LLCGeneral Contractor107/08/2026
GAROFALO PLMBNG & HTG LTDPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SHAHRISH SHUVO ENGINEERIN8524103/26/2026
HRF SERVICES CORP5616708/06/2025
Building Lifecycle
All (84)Filed (8)Permit Issued (5)Signed Off (3)Violation (16)Inspection (8)Objection (14)Special Inspection (30)
06/04/2026
Signed off — Alteration CO
MECHANICAL SPECIFICATION FILED IN CONJUNCTION WITH GC APPLICATION #X00837908-I1
X00837908-S5
06/01/2026
Permit issued — Structural
X00837908-S5-ST
03/26/2026
Filed — Alteration CO
MECHANICAL SPECIFICATION FILED IN CONJUNCTION WITH GC APPLICATION #X00837908-I1
X00837908-S5
03/17/2026
Special inspection requirement — Final
Shahrish Shuvo
03/17/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Shahrish Shuvo
03/17/2026
Special inspection requirement — Structural Cold-Formed Steel
Shahrish Shuvo
03/17/2026
Special inspection requirement — Structural Steel - Details
Shahrish Shuvo
08/21/2025
Special inspection requirement — Maintenance information
FAHAD FATEH
08/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
08/21/2025
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
08/21/2025
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
08/21/2025
Special inspection requirement — Fenestration air leakage
FAHAD FATEH
08/21/2025
Special inspection requirement — Fenestration areas
FAHAD FATEH
08/21/2025
Special inspection requirement — Interior lighting power
FAHAD FATEH
08/21/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
FAHAD FATEH
08/21/2025
Special inspection requirement — Metering
FAHAD FATEH
08/06/2025
Filed — Alteration CO
MECHANICAL SPECIFICATION FILED IN CONJUNCTION WITH GC APPLICATION #X00837908-I1
X00837908-P4
08/06/2025
Special inspection requirement — Maintenance information
FAHAD FATEH
08/06/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
FAHAD FATEH
08/06/2025
Special inspection requirement — Fenestration areas
FAHAD FATEH
08/06/2025
Special inspection requirement — Fenestration air leakage
FAHAD FATEH
08/06/2025
Special inspection requirement — Metering
FAHAD FATEH
08/06/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
08/06/2025
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
08/06/2025
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
08/06/2025
Special inspection requirement — Interior lighting power
FAHAD FATEH
06/20/2025
Filed — Alteration CO
MECHANICAL SPECIFICATION FILED IN CONJUNCTION WITH GC APPLICATION #X00837908-I1
X00837908-P3
06/18/2025
Special inspection requirement — Fenestration air leakage
FAHAD FATEH
06/18/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
06/18/2025
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
06/18/2025
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
06/18/2025
Special inspection requirement — Interior lighting power
FAHAD FATEH
06/18/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
FAHAD FATEH
06/18/2025
Special inspection requirement — Metering
FAHAD FATEH
06/18/2025
Special inspection requirement — Fenestration areas
FAHAD FATEH
05/08/2025
Permit issued — General Construction
X00837908-I1-GC
11/15/2024
Violation issued (HPD, open)
B
11/15/2024
Violation issued (HPD, open)
B
11/15/2024
Violation issued (HPD, open)
A
11/15/2024
Violation issued (HPD, open)
A
11/15/2024
Violation issued (HPD, open)
B
11/15/2024
Violation issued (HPD, open)
A
11/15/2024
Violation issued (HPD, closed)
A
11/15/2024
Violation issued (HPD, open)
B
11/15/2024
Violation issued (HPD, open)
B
11/15/2024
Violation issued (HPD, open)
B
11/15/2024
Violation issued (HPD, open)
B
05/09/2024
Signed off — Alteration CO
MECHANICAL SPECIFICATION FILED IN CONJUNCTION WITH GC APPLICATION #X00837908-I1
X00837908-S4
05/09/2024
Signed off — Alteration CO
MECHANICAL SPECIFICATION FILED IN CONJUNCTION WITH GC APPLICATION #X00837908-I1
X00837908-S1
04/15/2024
Objection resolved — Addressed
03/27/2024
Objection raised — Other
03/11/2024
Filed — Alteration CO
MECHANICAL SPECIFICATION FILED IN CONJUNCTION WITH GC APPLICATION #X00837908-I1
X00837908-P2
03/05/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
03/01/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
02/22/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/01/2024
Permit issued — Mechanical Systems
X00837908-S1-MS
01/25/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
12/01/2023
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
12/01/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
12/01/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
Latest 60 of 84 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offYNR CONSTRUCTION LLC06/01/2026
DOB NOWGeneral ConstructionPermit IssuedAB BUILDERS NY05/08/2025
DOB NOWMechanical SystemsSigned-offAB BUILDERS NY02/01/2024
DOB NOWSprinklersSigned-offAMOK INC11/17/2023
DOB NOWSprinklersSigned-offGAROFALO PLMBNG & HTG LTD11/17/2023
1 job · most recent 03/26/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
03/26/2026Signed-offYNR CONSTRUCTION LLCHeating and Air Conditioning Systems
Heat / Cool
Daikin RX18AXVJU 21,600 BTU · Condensing Unit ×8
RX18BXVJU 10,000 BTU · Heat Pump Outdoor ×2
1 job · most recent 03/26/2026
Sprinkler System
FiledStatusContractorScope
03/26/2026Signed-offAMOK INCSprinkler System
1 job · most recent 03/26/2026
Storm Water/Sanitary
FiledStatusContractorScope
03/26/2026Signed-offNATIONWIDE PLUMBERS NY COStorm, Water/Sanitary
1 job · most recent 10/30/2024
General Wiring
FiledStatusContractorScope
10/30/2024CompleteFRIED ELECTRIC CO.General Wiring
1 job · most recent 03/26/2026
Steel
FiledStatusContractorScope
03/26/2026Signed-offYNR CONSTRUCTION LLCSteel
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
03/05/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
03/01/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/22/2024Pass-Final CND-Occupancy InspectionPassView ↗
01/25/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/01/2023Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
12/01/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
12/01/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/01/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 56
DateRequirementInspectorRole
03/17/2026FinalShahrish Shuvoprogress
03/17/2026Structural Stability – Alterations of existing buildingsShahrish Shuvospecial
03/17/2026Structural Cold-Formed SteelShahrish Shuvospecial
03/17/2026Structural Steel - DetailsShahrish Shuvospecial
08/21/2025Maintenance informationFAHAD FATEHenergy_progress
08/21/2025Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
08/21/2025Fire-Resistance Rated ConstructionFAHAD FATEHprogress
08/21/2025Energy Code Compliance InspectionsFAHAD FATEHprogress
08/21/2025Fenestration air leakageFAHAD FATEHenergy_progress
08/21/2025Fenestration areasFAHAD FATEHenergy_progress
08/21/2025Interior lighting powerFAHAD FATEHenergy_progress
08/21/2025Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
08/21/2025MeteringFAHAD FATEHenergy_progress
08/06/2025Maintenance informationFAHAD FATEHenergy_progress
08/06/2025Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
08/06/2025Fenestration areasFAHAD FATEHenergy_progress
08/06/2025Fenestration air leakageFAHAD FATEHenergy_progress
08/06/2025MeteringFAHAD FATEHenergy_progress
08/06/2025Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
08/06/2025Fire-Resistance Rated ConstructionFAHAD FATEHprogress
08/06/2025Energy Code Compliance InspectionsFAHAD FATEHprogress
08/06/2025Interior lighting powerFAHAD FATEHenergy_progress
06/18/2025Fenestration air leakageFAHAD FATEHenergy_progress
06/18/2025Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
06/18/2025Energy Code Compliance InspectionsFAHAD FATEHprogress
Latest 25 of 56.
▾Documents — 54 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/17/2026X00837908-S1Request digital key ↗
08/17/2026X00837908-S4Request digital key ↗
08/17/2026X00837908-S5Request digital key ↗
Showing 3 of 8 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026X00837908-I1Open ↗
▸Seals & Professional Certifications27
▸DOB NOWProgress Inspector Seal & Signature12
09/23/2026X00837908-S4Open ↗
09/02/2026X00837908-S1Open ↗
09/02/2026X00837908-S1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/17/2026X00837908-S1Open ↗
08/17/2026X00837908-I1Open ↗
08/17/2026X00837908-S5Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/23/2026X00837908-S4Open ↗
09/02/2026X00837908-S1Open ↗
09/01/2026X00837908-S5Open ↗
Showing 3 of 7 on file for this type
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist5
08/13/2026X00837908-P4Open ↗
08/13/2026X00837908-P3Open ↗
08/13/2026X00837908-P1Open ↗
Showing 3 of 5 on file for this type
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/17/2026X00837908-S1Open ↗
08/17/2026X00837908-S5Open ↗
08/17/2026X00837908-P4Open ↗
Showing 3 of 8 on file for this type
▸Other Documents5
▸DOB NOWProperty Ownership Certification5
08/17/2026X00837908-P4Open ↗
08/17/2026X00837908-P3Open ↗
08/17/2026X00837908-P1Open ↗
Showing 3 of 5 on file for this type