← Back
BROOKLYN
215 CALYER STREET
BROOKLYN · BIN 3430516
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
Locations of Work
Architecture
Permit Issued — active, not yet Signed-off
RoofUnder Construction1 filing · 20 docs
Floor 5Under Construction1 filing · 20 docs
Floor 4Under Construction1 filing · 20 docs
Floor 3Under Construction1 filing · 20 docs
Floor 2Under Construction1 filing · 20 docs
Floor 1Under Construction1 filing · 20 docs
BasementUnder Construction1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NEVILLE ENGINEERING GROUP503/18/2026
NODE ARCHITECTURE,ENGINEERING, CONS509/17/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
QMB PLUMBING & HEATING INCPlumbing406/27/2026
LBM CONSTRUCTION OF NY INGeneral Contractor306/27/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
INTERNATIONAL GEOTEHCNICA1795803/18/2026
Building Lifecycle
All (102)Filed (10)Permit Issued (9)Signed Off (6)Inspection (10)Objection (42)Special Inspection (25)
05/04/2026
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
03/18/2026
Filed — New Building
HEREWITH FILING APPLICATION FOR EXTERIOR PLUMBING WORK.
B00561243-P4
12/23/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/04/2025
Permit issued — General Construction
B00561243-I1-GC
09/19/2025
Signed off — New Building
HEREWITH FILING APPLICATION FOR EXTERIOR PLUMBING WORK.
B00561243-S2
09/18/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
MICHAEL KARANTINIDIS, P.E.
09/18/2025
Special inspection requirement — HVAC-R and service water heating equipment
MICHAEL KARANTINIDIS, P.E.
09/18/2025
Special inspection requirement — Energy Code Compliance Inspections
MICHAEL KARANTINIDIS, P.E.
09/18/2025
Special inspection requirement — Final
MICHAEL KARANTINIDIS, P.E.
09/18/2025
Special inspection requirement — Fire-Resistance Rated Construction
MICHAEL KARANTINIDIS, P.E.
09/18/2025
Special inspection requirement — Shutoff dampers
MICHAEL KARANTINIDIS, P.E.
09/18/2025
Special inspection requirement — Maintenance information
MICHAEL KARANTINIDIS, P.E.
09/18/2025
Special inspection requirement — HVAC-R and service water heating system controls
MICHAEL KARANTINIDIS, P.E.
09/18/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
MICHAEL KARANTINIDIS, P.E.
09/18/2025
Special inspection requirement — Mechanical Systems
MICHAEL KARANTINIDIS, P.E.
09/17/2025
Filed — New Building
HEREWITH FILING APPLICATION FOR EXTERIOR PLUMBING WORK.
B00561243-P3
09/15/2025
Signed off — New Building
HEREWITH FILING APPLICATION FOR EXTERIOR PLUMBING WORK.
B00561243-S3
08/25/2025
Signed off — New Building
HEREWITH FILING APPLICATION FOR EXTERIOR PLUMBING WORK.
B00561243-S7
08/20/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/19/2025
Signed off — New Building
HEREWITH FILING APPLICATION FOR EXTERIOR PLUMBING WORK.
B00561243-S5
08/19/2025
Signed off — New Building
HEREWITH FILING APPLICATION FOR EXTERIOR PLUMBING WORK.
B00561243-S6
08/07/2025
Signed off — New Building
HEREWITH FILING APPLICATION FOR EXTERIOR PLUMBING WORK.
B00561243-S4
07/18/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
07/15/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
03/19/2025
Filed — New Building
HEREWITH FILING APPLICATION FOR EXTERIOR PLUMBING WORK.
B00561243-P1
01/28/2025
Permit issued — Structural
B00561243-S6-ST
01/23/2025
Permit issued — Mechanical Systems
B00561243-S2-MS
12/19/2024
Permit issued — General Construction
B00561243-I1-GC
12/12/2024
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
12/12/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/06/2024
Permit issued — Sprinklers
B00561243-S4-EW-SP
11/26/2024
Inspection — Pass-Final House Connection
Pass
View inspection ↗
11/21/2024
Permit issued — Plumbing
B00561243-S7-PL
11/18/2024
Filed — New Building
HEREWITH FILING APPLICATION FOR EXTERIOR PLUMBING WORK.
B00561243-S7
11/18/2024
Permit issued — Plumbing
B00561243-S7-PL
10/17/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
10/17/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
10/04/2024
Permit issued — Plumbing
B00561243-S3-PL
10/01/2024
Permit issued — Foundation
B00561243-S5-FO
08/19/2024
Objection resolved — Addressed
08/07/2024
Objection raised — Other
07/31/2024
Filed — New Building
HEREWITH FILING APPLICATION FOR EXTERIOR PLUMBING WORK.
B00561243-S5
07/31/2024
Filed — New Building
HEREWITH FILING APPLICATION FOR EXTERIOR PLUMBING WORK.
B00561243-S6
07/23/2024
Special inspection requirement — Concrete - Cast-In-Place
MICHAEL KARANTINIDIS, P.E.
07/15/2024
Special inspection requirement — Structural Steel - Welding
MICHAEL KARANTINIDIS, P.E.
07/15/2024
Special inspection requirement — Structural Steel - High Strength Bolting
MICHAEL KARANTINIDIS, P.E.
07/15/2024
Special inspection requirement — Structural Steel - Details
MICHAEL KARANTINIDIS, P.E.
07/15/2024
Special inspection requirement — Masonry
MICHAEL KARANTINIDIS, P.E.
07/15/2024
Special inspection requirement — Designated Seismic System
MICHAEL KARANTINIDIS, P.E.
07/11/2024
Special inspection requirement — Final
MICHAEL KARANTINIDIS, P.E.
07/11/2024
Special inspection requirement — Footing and Foundation
MICHAEL KARANTINIDIS, P.E.
07/11/2024
Special inspection requirement — Final
MICHAEL KARANTINIDIS, P.E.
06/20/2024
Filed — New Building
HEREWITH FILING APPLICATION FOR EXTERIOR PLUMBING WORK.
B00561243-S2
06/20/2024
Filed — New Building
HEREWITH FILING APPLICATION FOR EXTERIOR PLUMBING WORK.
B00561243-S3
06/19/2024
Filed — New Building
HEREWITH FILING APPLICATION FOR EXTERIOR PLUMBING WORK.
B00561243-S4
06/18/2024
Special inspection requirement — Maintenance information
MICHAEL KARANTINIDIS, P.E.
06/18/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
MICHAEL KARANTINIDIS, P.E.
06/18/2024
Special inspection requirement — HVAC-R and service water heating equipment
MICHAEL KARANTINIDIS, P.E.
06/18/2024
Special inspection requirement — Energy Code Compliance Inspections
MICHAEL KARANTINIDIS, P.E.
06/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
MICHAEL KARANTINIDIS, P.E.
Latest 60 of 102 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedLBM CONSTRUCTION OF NY IN12/04/2025
DOB NOWStructuralSigned-offLBM CONSTRUCTION OF NY IN01/28/2025
DOB NOWMechanical SystemsSigned-offLBM CONSTRUCTION OF NY IN01/23/2025
DOB NOWGeneral ConstructionPermit IssuedLBM CONSTRUCTION OF NY IN12/19/2024
DOB NOWSprinklersSigned-offQMB PLUMBING & HEATING INC12/06/2024
DOB NOWPlumbingSigned-offQMB PLUMBING & HEATING INC11/21/2024
DOB NOWPlumbingSigned-offQMB PLUMBING & HEATING INC11/18/2024
DOB NOWPlumbingSigned-offQMB PLUMBING & HEATING INC10/04/2024
DOB NOWFoundationSigned-offLBM CONSTRUCTION OF NY IN10/01/2024
1 project · most recent 03/18/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
03/18/2026Permit IssuedLBM CONSTRUCTION OF NY INHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-SM36NAMHZ 42,000 BTU · Heat Pump Outdoor ×2
MXZ-SM36NAMHZ2 42,000 BTU · Heat Pump Outdoor ×2
MUZ-FS09NA 9,600 BTU · Heat Pump Outdoor ×1
MXZ-SM42NAMHZ 48,000 BTU · Heat Pump Outdoor ×1
1 project · most recent 03/18/2026
Storm
FiledStatusContractorScope
03/18/2026Signed-offQMB PLUMBING & HEATING INStorm
1 project · most recent 03/18/2026
FiledStatusContractorScope
03/18/2026Permit IssuedLBM CONSTRUCTION OF NY IN2 scope_items
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
05/04/2026Pass-Final PL - Up to 9 Requested FloorsPassView ↗
12/23/2025Pass-Final CND-Occupancy InspectionPassView ↗
08/20/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/18/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
07/15/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
12/12/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
12/12/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/26/2024Pass-Final House ConnectionPassView ↗
10/17/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
10/17/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 25
DateRequirementInspectorRole
09/18/2025HVAC-R and service water piping design and insulationMICHAEL KARANTINIDIS, P.E.energy_progress
09/18/2025HVAC-R and service water heating equipmentMICHAEL KARANTINIDIS, P.E.energy_progress
09/18/2025Energy Code Compliance InspectionsMICHAEL KARANTINIDIS, P.E.progress
09/18/2025FinalMICHAEL KARANTINIDIS, P.E.progress
09/18/2025Fire-Resistance Rated ConstructionMICHAEL KARANTINIDIS, P.E.progress
09/18/2025Shutoff dampersMICHAEL KARANTINIDIS, P.E.energy_progress
09/18/2025Maintenance informationMICHAEL KARANTINIDIS, P.E.energy_progress
09/18/2025HVAC-R and service water heating system controlsMICHAEL KARANTINIDIS, P.E.energy_progress
09/18/2025Fire-Resistant Penetrations and JointsMICHAEL KARANTINIDIS, P.E.special
09/18/2025Mechanical SystemsMICHAEL KARANTINIDIS, P.E.special
07/23/2024Concrete - Cast-In-PlaceMICHAEL KARANTINIDIS, P.E.special
07/15/2024Structural Steel - WeldingMICHAEL KARANTINIDIS, P.E.special
07/15/2024Structural Steel - High Strength BoltingMICHAEL KARANTINIDIS, P.E.special
07/15/2024Structural Steel - DetailsMICHAEL KARANTINIDIS, P.E.special
07/15/2024MasonryMICHAEL KARANTINIDIS, P.E.special
07/15/2024Designated Seismic SystemMICHAEL KARANTINIDIS, P.E.special
07/11/2024FinalMICHAEL KARANTINIDIS, P.E.progress
07/11/2024Footing and FoundationMICHAEL KARANTINIDIS, P.E.progress
07/11/2024FinalMICHAEL KARANTINIDIS, P.E.progress
06/18/2024Maintenance informationMICHAEL KARANTINIDIS, P.E.energy_progress
06/18/2024HVAC-R and service water piping design and insulationMICHAEL KARANTINIDIS, P.E.energy_progress
06/18/2024HVAC-R and service water heating equipmentMICHAEL KARANTINIDIS, P.E.energy_progress
06/18/2024Energy Code Compliance InspectionsMICHAEL KARANTINIDIS, P.E.progress
06/18/2024Fire-Resistant Penetrations and JointsMICHAEL KARANTINIDIS, P.E.special
06/18/2024HVAC-R and service water heating system controlsMICHAEL KARANTINIDIS, P.E.energy_progress
▾Documents — 68 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/17/2026B00561243-S3Request digital key ↗
08/17/2026B00561243-P4Request digital key ↗
08/17/2026B00561243-P3Request digital key ↗
Showing 3 of 10 on file for this type
▸Zoning, Tax Lot & Property Records7
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026B00561243-I1Open ↗
08/13/2026B00561243-P4Open ↗
08/13/2026B00561243-P1Open ↗
▸DOB NOWZoning Exhibit form (1-5)3
08/13/2026B00561243-P1Open ↗
08/13/2026B00561243-P4Open ↗
08/13/2026B00561243-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00561243-I1Open ↗
▸Seals & Professional Certifications35
▸DOB NOWProgress Inspector Seal & Signature16
09/21/2026B00561243-S3Open ↗
09/21/2026B00561243-S3Open ↗
09/21/2026B00561243-S3Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/17/2026B00561243-P4Open ↗
08/17/2026B00561243-P3Open ↗
08/17/2026B00561243-P1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
09/21/2026B00561243-S3Open ↗
08/27/2026B00561243-S6Open ↗
08/27/2026B00561243-S6Open ↗
Showing 3 of 9 on file for this type
▸Trade Schedules & Equipment3
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)3
08/13/2026B00561243-P1Open ↗
08/13/2026B00561243-P4Open ↗
08/13/2026B00561243-I1Open ↗
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist3
08/17/2026B00561243-P4Open ↗
08/17/2026B00561243-P1Open ↗
08/15/2026B00561243-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026B00561243-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026B00561243-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026B00561243-I1Open ↗
▸Cost, Insurance & Ownership2
▸DOB NOWCertification by Insurance Broker or Agency1
08/13/2026B00561243-I1Open ↗
▸DOB NOWCertificate of Insurance1
08/13/2026B00561243-I1Open ↗
▸Other Documents5
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026B00561243-P1Open ↗
08/13/2026B00561243-P4Open ↗
08/13/2026B00561243-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026B00561243-P4Open ↗
▸DOB NOWAdditional Insured Authorizations1
08/13/2026B00561243-I1Open ↗