DOB03/24/2026Ftm bldg. Observed @ EXP1: cracks in mortar joints, cracks in bricks work, flower pots on outside of balcony, corroded sagging metal lentil and damaged joints. At exp 3: spalling lentil top floor/missing brick multiple locations. Remedy:repair and/or replace defective conditions
DOB05/02/2024The occupied parking structure with conc. Framing observed to be in state of disrepair. Cracks, conc. Spalling & exposed steel reinf. Observed on columns & structural beams @ various lvls/locations. Crushed column base observed at several locations in sub-cellar lvl. Vert cracks observed on masonry walls @ various lvls/locations.
HPD06/02/2022§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL, 1st STORY
HPD06/02/2022§ 26-1103 admin. Code: post and maintain a proper notice on wall of the entrance story in english and spanish on the availability of the agencys housing information guide. A sample notice can be found at www.NYC.gov/HPD.
HPD06/02/2022§ 27-2046.1 hmc: post a proper notice of carbon monoxide detecting device requirements, in a form approved by the commissioner, in a common area of a class a multiple dwelling near inspection certificate or provide notice to tenants in a private dwelling.
HPD06/02/2022§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
HPD06/02/2022§ 27-2005 hmc: post, in a form approved by the commissioner, and maintain a notice in a common area of the building regarding the procedures that should be followed when a gas leak is suspected
HPD06/02/2022§ 27-2045 ADM code post a proper notice of smoke detector requirements, in a form approved by the commissioner, at or near the mail box missing
HPD06/02/2022§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY
HPD02/01/2022§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE UPPER WINDOW SASH IN THE 2nd ROOM FROM NORTH LOCATED AT APT 612, 6th STORY, 8th APARTMENT FROM EAST AT SOUTH
HPD02/14/2020§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE TRANSOM LIGHTS EXTERIOR GLASS PANE OVER TERRACE DOOR IN THE 1st ROOM FROM EAST LOCATED AT APT 612, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST
ECB12/15/2023Failure to maintain exterior building facade and appurtenances. Noted at time of inspection east elevation exposure #4. (1) spalling concrete at parapet level at area of steel support beam. (2) open vertical moNothing owed — awaiting certificate of correction
ECB12/30/2021Existing exhaust fan and parts shall be maintained in accorance with original design as per mc-102.3. Owner shall inspect the existing exhaust fan and parts as per mc-102.3.1; mc-misc., comply with notice of viNothing owed — awaiting certificate of correction
Old · issued 3+ years ago and still listed by DOB; nothing on the city's records either way
DOB02/17/2022Cycle 9A unsafe report filedIssued 2022; DOB's record still lists it as active
DOB02/17/2022Cycle 9A failure to correct swarmp conditionsIssued 2022; DOB's record still lists it as active