← Back
One family attached or semi-detached
2152 EAST 18 STREET
BROOKLYN · Madison · BIN 3199689
💬 Discuss this project
1925Year Built
2Stories
A5Building Class
R5Zoning
1,232 sfGross Floor Area
1Units
One family attached or semi-detached · 1,080 sf lot · 1.14 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 216p · 2 filings · 20 docs
Floor 115p · 2 filings · 20 docs
Sub-Basement14p · 2 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/22/2022$970K—Private party → Private party$787/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
J&R DESIGN AND INSPECTION CORP.411/01/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HIGH QUALITY 338803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HIGH QUALITY CONSTRUCTIONGeneral Contractor107/08/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
J&R DESIGN AND INSPECTION6637411/01/2023
Building Lifecycle
All (34)Filed (4)Permit Issued (2)Signed Off (2)Inspection (4)Special Inspection (22)
11/21/2023
Signed off — Alteration
GENERAL RENOVATION OF 1-FAMILY HOUSE WITH REPAIR/REPLACE PARTITION, DOOR, WINDOW, CEILING, FLOOR, AWNING, PAINTING AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00804228-I1
11/02/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Truskosky
11/02/2023
Special inspection requirement — Final
Robert Truskosky
11/02/2023
Special inspection requirement — Energy Code Compliance Inspections
Robert Truskosky
11/02/2023
Special inspection requirement — Fire-Resistance Rated Construction
Robert Truskosky
11/01/2023
Filed — Alteration
GENERAL RENOVATION OF 1-FAMILY HOUSE WITH REPAIR/REPLACE PARTITION, DOOR, WINDOW, CEILING, FLOOR, AWNING, PAINTING AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00804228-P1
10/26/2023
Special inspection requirement — Fenestration areas
Robert Truskosky
10/26/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Truskosky
10/26/2023
Special inspection requirement — Energy Code Compliance Inspections
Robert Truskosky
10/26/2023
Special inspection requirement — Final
Robert Truskosky
10/26/2023
Special inspection requirement — Fire-Resistance Rated Construction
Robert Truskosky
10/26/2023
Special inspection requirement — Air barrier - visual inspection
Robert Truskosky
10/26/2023
Special inspection requirement — Fenestration air leakage
Robert Truskosky
10/26/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
Robert Truskosky
10/12/2023
Signed off — Alteration
GENERAL RENOVATION OF 1-FAMILY HOUSE WITH RELOCATED/REPLACE/NEW PLUMBING FIXTURES AND BOILER AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00804229-I1
07/19/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/19/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/19/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/19/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/14/2023
Special inspection requirement — HVAC-R and service water heating system controls
Robert Truskosky
07/14/2023
Special inspection requirement — HVAC-R and service water heating equipment
Robert Truskosky
07/14/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Truskosky
07/14/2023
Special inspection requirement — Energy Code Compliance Inspections
Robert Truskosky
07/14/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Robert Truskosky
07/12/2023
Filed — Alteration
GENERAL RENOVATION OF 1-FAMILY HOUSE WITH RELOCATED/REPLACE/NEW PLUMBING FIXTURES AND BOILER AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00804229-P1
07/12/2023
Special inspection requirement — HVAC-R and service water heating system controls
Robert Truskosky
07/12/2023
Special inspection requirement — HVAC-R and service water heating equipment
Robert Truskosky
07/12/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Truskosky
07/12/2023
Special inspection requirement — Energy Code Compliance Inspections
Robert Truskosky
07/12/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Robert Truskosky
01/24/2023
Permit issued — General Construction
B00804228-I1-GC
01/23/2023
Permit issued — Plumbing
B00804229-I1-PL
01/20/2023
Filed — Alteration
GENERAL RENOVATION OF 1-FAMILY HOUSE WITH REPAIR/REPLACE PARTITION, DOOR, WINDOW, CEILING, FLOOR, AWNING, PAINTING AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00804228-I1
01/20/2023
Filed — Alteration
GENERAL RENOVATION OF 1-FAMILY HOUSE WITH RELOCATED/REPLACE/NEW PLUMBING FIXTURES AND BOILER AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00804229-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offHIGH QUALITY CONSTRUCTION01/24/2023
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.01/23/2023
2 projects · most recent 10/17/2023
General Wiring
FiledStatusContractorScope
10/17/2023CompleteKJK ELECTRIC INCGeneral Wiring
02/17/2023CompleteA ELECTRICAL MAIN SVC INC1 meters, 1 new_meters
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
07/19/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/19/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/19/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/19/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 22
DateRequirementInspectorRole
11/02/2023Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
11/02/2023FinalRobert Truskoskyprogress
11/02/2023Energy Code Compliance InspectionsRobert Truskoskyprogress
11/02/2023Fire-Resistance Rated ConstructionRobert Truskoskyprogress
10/26/2023Fenestration areasRobert Truskoskyenergy_progress
10/26/2023Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
10/26/2023Energy Code Compliance InspectionsRobert Truskoskyprogress
10/26/2023FinalRobert Truskoskyprogress
10/26/2023Fire-Resistance Rated ConstructionRobert Truskoskyprogress
10/26/2023Air barrier - visual inspectionRobert Truskoskyenergy_progress
10/26/2023Fenestration air leakageRobert Truskoskyenergy_progress
10/26/2023Fenestration and door U-factor and product ratingsRobert Truskoskyenergy_progress
07/14/2023HVAC-R and service water heating system controlsRobert Truskoskyenergy_progress
07/14/2023HVAC-R and service water heating equipmentRobert Truskoskyenergy_progress
07/14/2023Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
07/14/2023Energy Code Compliance InspectionsRobert Truskoskyprogress
07/14/2023HVAC-R and service water piping design and insulationRobert Truskoskyenergy_progress
07/12/2023HVAC-R and service water heating system controlsRobert Truskoskyenergy_progress
07/12/2023HVAC-R and service water heating equipmentRobert Truskoskyenergy_progress
07/12/2023Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
07/12/2023Energy Code Compliance InspectionsRobert Truskoskyprogress
07/12/2023HVAC-R and service water piping design and insulationRobert Truskoskyenergy_progress
▾Documents — 34 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/27/2026B00804229-I1Request digital key ↗
08/27/2026B00804229-P1Request digital key ↗
08/27/2026B00804228-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications26
▸DOB NOWProgress Inspector Seal & Signature18
09/26/2026B00804228-I1Open ↗
09/26/2026B00804228-I1Open ↗
09/26/2026B00804228-I1Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/27/2026B00804228-P1Open ↗
08/27/2026B00804228-I1Open ↗
08/13/2026B00804229-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/26/2026B00804228-I1Open ↗
08/31/2026B00804229-P1Open ↗
08/30/2026B00804229-I1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/27/2026B00804228-I1Open ↗
08/27/2026B00804228-P1Open ↗
08/13/2026B00804229-P1Open ↗