← Back
Two stories - detached, small or mid-size
216-22 110 AVENUE
QUEENS · BIN 4239953
💬 Discuss this project
1930Year Built
2Stories
A1Building Class
R2Zoning
1,488 sfGross Floor Area
1Units
Rent Stabilized17 Open Violations ▸FDNY Report ↗
Two stories - detached, small or mid-size · 4,000 sf lot · 0.37 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Roof2p · 1 filing · 11 docs
Floor 21p · 1 filing · 11 docs
Floor 11p · 1 filing · 11 docs
Cellar1p · 1 filing · 11 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/22/2016$465K—Private party → Private party$312/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ANTHONY CUCICH ARCHITECT304/08/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
3R1 GROUP403/21/2026
Building Lifecycle
All (77)Filed (3)Violation (21)Objection (29)Special Inspection (24)
07/10/2026
Objection raised — Zoning
06/26/2026
Objection resolved — Resolved
06/26/2026
Objection resolved — Addressed
06/25/2026
Objection resolved — Resolved
05/26/2026
Objection resolved — Resolved
05/26/2026
Objection resolved — Resolved
05/04/2026
Objection raised — Fire_Protection
05/04/2026
Objection raised — Other
05/04/2026
Objection raised — Scope
05/01/2026
Objection raised — Structural
04/28/2026
Objection raised — Other
04/28/2026
Objection raised — Scope
04/28/2026
Objection raised — Inspections
04/08/2026
Filed — Alteration CO
PROPOSED TWO (2) STORY ADDITION TO AN EXISTING TWO AND A HALF (2 1/2) STORY DETACHED HOUSE; ADDING ONE (1) ANCILLARY DWELLING UNIT; PROPOSED NEW ENCLOSED TWO-CAR ATTACHED GARAGE
Q01341943-S1
04/08/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
04/08/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
03/17/2026
Special inspection requirement — Electric vehicle service equipment requirements
03/05/2026
Objection resolved — Resolved
02/17/2026
Objection resolved — Resolved
02/17/2026
Objection resolved — Resolved
02/17/2026
Objection resolved — Resolved
02/17/2026
Objection resolved — Resolved
02/17/2026
Objection resolved — Resolved
02/17/2026
Objection resolved — Resolved
02/04/2026
Objection raised — Other
02/04/2026
Objection raised — Zoning
02/04/2026
Objection raised — Structural
02/04/2026
Objection raised — Structural
02/04/2026
Objection raised — Zoning
02/04/2026
Objection raised — Zoning
02/04/2026
Objection raised — Energy
01/21/2026
Objection resolved — Addressed
01/20/2026
Objection raised — Admin
01/14/2026
Filed — Alteration
NEW TEMPORARY 8'-0" WOOD CONSTRUCTION FENCE
Q01344245-I1
01/05/2026
Filed — Alteration CO
PROPOSED TWO (2) STORY ADDITION TO AN EXISTING TWO AND A HALF (2 1/2) STORY DETACHED HOUSE; ADDING ONE (1) ANCILLARY DWELLING UNIT; PROPOSED NEW ENCLOSED TWO-CAR ATTACHED GARAGE
Q01341943-I1
01/04/2026
Special inspection requirement — Fire-Resistance Rated Construction
01/04/2026
Special inspection requirement — Lowest Floor Elevation
01/04/2026
Special inspection requirement — Final
01/04/2026
Special inspection requirement — Footing and Foundation
01/04/2026
Special inspection requirement — Interior lighting power
01/04/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
01/04/2026
Special inspection requirement — Maintenance information
01/04/2026
Special inspection requirement — Fenestration areas
01/04/2026
Special inspection requirement — Metering
01/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
01/04/2026
Special inspection requirement — Ventilation and air distribution system
01/04/2026
Special inspection requirement — Permanent certificate
01/04/2026
Special inspection requirement — Air barrier — testing
01/04/2026
Special inspection requirement — HVAC-R and service water heating equipment
01/04/2026
Special inspection requirement — HVAC-R and service water heating system controls
01/04/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
01/04/2026
Special inspection requirement — Air barrier - visual inspection
01/04/2026
Special inspection requirement — Fenestration air leakage
01/04/2026
Special inspection requirement — Insulation placement and R values
01/04/2026
Special inspection requirement — Mechanical Systems
01/04/2026
Special inspection requirement — Energy Code Compliance Inspections
11/25/2025
Violation issued (HPD, open)
I
12/05/2024
Violation issued (HPD, open)
I
11/29/2023
Violation issued (HPD, open)
I
11/18/2022
Violation issued (HPD, open)
I
Latest 60 of 77 events.
Nothing on file for this building.
1 project · most recent 04/08/2026
Heating and Air Conditioning Systems Others
FiledStatusContractorScopeMake / Model / Capacity
04/08/2026——Heating and Air Conditioning Systems, Others
Heat / Cool
Fujitsu AOU36RLXFZH 36,000 BTU · Condensing Unit ×1
Other
A.O. Smith SIGNATURE 100 LOWBOY: E6-30L45DVB 15,345 BTU · Electric Heater ×1
1 project · most recent 04/08/2026
Concrete Wood
FiledStatusContractorScope
04/08/2026——Concrete, Wood
1 project · most recent 01/14/2026
Fence
FiledStatusContractorScope
01/14/2026——Fence
▾Special Inspection Requirements (DOB NOW) — 24
DateRequirementInspectorRole
04/08/2026Fire-Resistant Penetrations and Joints—special
04/08/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
03/17/2026Electric vehicle service equipment requirements—energy_progress
01/04/2026Fire-Resistance Rated Construction—progress
01/04/2026Lowest Floor Elevation—progress
01/04/2026Final—progress
01/04/2026Footing and Foundation—progress
01/04/2026Interior lighting power—energy_progress
01/04/2026Fenestration and door U-factor and product ratings—energy_progress
01/04/2026Maintenance information—energy_progress
01/04/2026Fenestration areas—energy_progress
01/04/2026Metering—energy_progress
01/04/2026Fire-Resistant Penetrations and Joints—special
01/04/2026Ventilation and air distribution system—energy_progress
01/04/2026Permanent certificate—energy_progress
01/04/2026Air barrier — testing —energy_progress
01/04/2026HVAC-R and service water heating equipment—energy_progress
01/04/2026HVAC-R and service water heating system controls—energy_progress
01/04/2026HVAC-R and service water piping design and insulation—energy_progress
01/04/2026Air barrier - visual inspection—energy_progress
01/04/2026Fenestration air leakage—energy_progress
01/04/2026Insulation placement and R values—energy_progress
01/04/2026Mechanical Systems—special
01/04/2026Energy Code Compliance Inspections—progress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/17/2026Q01341943-I1Request digital key ↗
08/17/2026Q01341943-S1Request digital key ↗
08/17/2026Q01344245-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram2
08/17/2026Q01341943-I1Open ↗
08/13/2026Q01341943-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01341943-I1Open ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/17/2026Q01341943-S1Open ↗
08/17/2026Q01341943-I1Open ↗
08/17/2026Q01344245-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026Q01341943-I1Open ↗
▸Other Documents3
▸DOB NOWSite Survey: Initial1
08/13/2026Q01341943-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026Q01341943-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/17/2026Q01341943-I1Open ↗