← Back
One story retail building
2161 STARLING AVENUE
BRONX · Parkchester · BIN 2041227
💬 Discuss this project
1952Year Built
1Stories
K1Building Class
R6Zoning
5,700 sfGross Floor Area
7Units
0 Open Violations
One story retail building · Owner of record: TRAMONTI 7870 REALTY LLC · 10,290 sf lot · 0.55 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Roof1p · 1 filing · 7 docs
Cellar1p · 1 filing · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
VIOLA SANTELIA REALTY1007/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PENNAARCHITECT PC210/10/2019
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ACS ENVIRONMENTAL & CONSTGeneral Contractor303/21/2026
CAPE PLUMBING INCPlumbing207/08/2026
BISHUNDAT, CHRISTOPHERElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ECOPLUSDESIGN2887110/10/2019
Building Lifecycle
All (13)Filed (2)Permit Issued (3)Violation (3)Special Inspection (5)
03/27/2025
Permit issued — Plumbing
X00232567-I1-PL
11/07/2019
Permit issued — Plumbing
X00232567-I1-PL
11/06/2019
Permit issued — Mechanical Systems
X00235462-I1-MS
10/10/2019
Filed — Alteration
REPLACEMENTPLBG FIXTURES ON EXIS ROUGHING AND INSTALL GAS LINE ON EXIST'G. GAS METER FROM CELLAR TO ROOF HVAC UNIT FILED UNDER DOB NOW#X00235462 IN CONJUNCTION WITH ALT.#220715405 AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY
X00232567-I1
10/10/2019
Filed — Alteration
FILING INSTALLATION OF ROOF MOUNTED (1) 7.5 TON GAS FIRED HVAC UNIT AND (5) COMPRESSORS FOR REFRIGERATION EQUIPMENTS ON EXISTING STEEL DUNNAGE IN CONJUNCTION WITH ALT.#220715402 AS PER PLNS SUBMITTED. NO CHANGE OF USE, EGRESS OR OCCUPANY.
X00235462-I1
10/10/2019
Special inspection requirement — HVAC and service water heating equipment
GIULIANO PENNA
09/28/2019
Special inspection requirement — HVAC and service water heating equipment
GIULIANO PENNA
09/28/2019
Special inspection requirement — HVAC and service water heating system controls
GIULIANO PENNA
09/26/2019
Special inspection requirement — Mechanical Systems
Seungchul Ok
09/26/2019
Special inspection requirement — Final
GIULIANO PENNA
11/05/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/12/2006
Violation issued (ECB, closed)
Construction
04/22/1991
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedCAPE PLUMBING INC03/27/2025
DOB NOWPlumbingPermit IssuedCAPE PLUMBING INC11/07/2019
DOB NOWMechanical SystemsPermit IssuedACS ENVIRONMENTAL & CONST11/06/2019
BISOTISSUEDACS ENVIRONMENTAL & CONST08/21/2019
BISFPISSUEDMASTER FIRE SYSTEMS, INC08/29/2008
BISFPISSUEDNEW YORK BUSINESS FIRE SYSTEM IN06/07/2007
BISPLISSUEDS & L PLUMBING INC05/02/2007
BISOTISSUEDCKC CONSTRUCTION LLC04/11/2007
BISPLISSUEDA.GOLDNER INC12/07/2006
BISOTISSUEDPAK BARKA GROUP INC.11/13/2006
BISEQISSUEDPAK BARKA GROUP INC.11/13/2006
BISOTISSUEDZEE SHAWN CONTRACTING CORP.11/09/2006
BISOTISSUEDARCHITECTURAL DESIGN SOLUTIONS10/06/2006
BISPLISSUEDSKYVIEW HTG&AIR CON CORP05/30/1997
BISOTISSUEDMARCIANO CONSTRUCTION CORP04/11/1997
BISEQISSUEDMARCIANO CONSTRUCTION CORP04/11/1997
1 project · most recent 10/10/2019
Air Conditioning Systems Heating Systems Refrigeration Systems
FiledStatusContractorScopeMake / Model / Capacity
10/10/2019Permit IssuedACS ENVIRONMENTAL & CONSTAir Conditioning Systems, Heating Systems, Refrigeration Systems
Cooling
American Standard YSC092HA030 90,000 BTU · Condensing Unit ×1
Heating
American Standard YSC092HA030 160,000 BTU · Condensing Unit ×1
Refrigeration
Trenton TEZA010H8-HS2C-B 1 tons · Refrigeration Unit ×3
TEZA020L8HS2CF 2 tons · Refrigeration Unit ×1
TEZA030L8HS2CF 3 tons · Refrigeration Unit ×1
1 project · most recent 10/10/2019
Gas
FiledStatusContractorScope
10/10/2019Permit IssuedCAPE PLUMBING INCGas
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
10/10/2019HVAC and service water heating equipment GIULIANO PENNAenergy_progress
09/28/2019HVAC and service water heating equipment GIULIANO PENNAenergy_progress
09/28/2019HVAC and service water heating system controls GIULIANO PENNAenergy_progress
09/26/2019Mechanical SystemsSeungchul Okspecial
09/26/2019FinalGIULIANO PENNAprogress
▾Documents — 21 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Plumbing1
08/26/2026X00232567-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/26/2026X00235462-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
08/22/2019220715402Open ↗
▸BISWORK PERMIT APPLICATION1
08/22/2019220715402Open ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature4
08/31/2026X00232567-I1Open ↗
08/24/2026X00235462-I1Open ↗
08/24/2026X00235462-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/26/2026X00235462-I1Open ↗
08/26/2026X00232567-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
08/22/2019220715402Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
08/22/2019220715402Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
08/22/2019220715402Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026X00235462-I1Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
08/22/2019220715402Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/26/2026X00235462-I1Open ↗
08/26/2026X00232567-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
08/22/2019220715402Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
08/22/2019220715402Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
08/22/2019220715402Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1