← Back
BuildNYC
Three families
2166 HOMECREST AVENUE
BROOKLYN · BIN 3256876
💬 Discuss this project
1910Year Built
2.75Stories
C0Building Class
R5Zoning
1,932 sfGross Floor Area
3Units
2 Active Violations ▸FDNY Report ↗
Three families · 3,000 sf lot · 0.64 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralPlumbingFire ProtectionEquipmentGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
RoofProposed alterationUnder Construction3p · 1 filing · 20 docs
AtticProposed alterationUnder Construction37p · 1 filing · 20 docs
Floor 3Proposed alterationUnder Construction5p · 1 filing · 20 docs
Floor 2Proposed alterationUnder Construction44p · 1 filing · 20 docs
Floor 1Proposed alterationUnder Construction41p · 1 filing · 20 docs
CellarProposed alterationUnder Construction41p · 1 filing · 20 docs
Site & exteriorProposed alterationUnder Construction53p · 1 filing · 20 docs
Filed — no permit issued18p · 1 filing · 4 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/13/2025$1.9M—Private party → Private party$999/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Garfinkel Architect509/15/2026
Eyal Levitt Architect101/30/2026
Adroit Engineering112/31/2025
Derman Engineering211/04/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Garfinkel Architect403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RHY ConstructionGeneral Contractor507/08/2026
RHY ConstructionScaffold104/09/2026
RRP PlumbingPlumbing106/27/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AZ Professional Engineering766509/15/2026
Building Lifecycle
11/10/2026
Permit expired, never signed off — General Construction
The city's record still shows this permit as issued, with no sign-off on its filing
B01185649-I1-GC
10/31/2026
Permit expired, never signed off — Construction Fence
The city's record still shows this permit as issued, with no sign-off on its filing
B01185649-S3-FN
09/24/2026
Objection resolved — Resolved
09/23/2026
Objection raised — Other
09/15/2026
Filed — Alteration CO
Temporary construction fence in conjunction with B01185649-I1
B01185649-P2
98 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedRRP Plumbing06/23/2026
DOB NOWFoundationPermit IssuedRHY Construction02/23/2026
DOB NOWStructuralPermit IssuedRHY Construction02/13/2026
DOB NOWGeneral ConstructionPermit IssuedRHY Construction11/10/2025
DOB NOWConstruction FencePermit IssuedRHY Construction10/31/2025
1 project · most recent 09/15/2026
Sprinkler System
FiledStatusContractorScope
09/15/2026——Sprinkler System
1 project · most recent 09/15/2026
Gas Water/Sanitary
FiledStatusContractorScope
09/15/2026Permit IssuedRRP PlumbingGas, Water/Sanitary
1 project · most recent 07/28/2026
General Wiring
FiledStatusContractorScope
07/28/2026Permit IssuedFabco ElectricalGeneral Wiring
1 project · most recent 09/15/2026
Steel Wood
FiledStatusContractorScope
09/15/2026Permit IssuedRRP PlumbingSteel, Wood
1 project · most recent 09/15/2026
Fence
FiledStatusContractorScope
09/15/2026Permit IssuedRRP PlumbingFence
1 project · most recent 09/15/2026
Earthwork
FiledStatusContractorScope
09/15/2026Permit IssuedRRP PlumbingEarthwork
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
08/04/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/04/2026Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 66
DateRequirementInspectorRole
09/09/2026Energy Code Compliance InspectionsVIJAY KUMARprogress
09/09/2026Fire-Resistance Rated ConstructionVIJAY KUMARprogress
09/09/2026PreliminaryVIJAY KUMARprogress
09/09/2026Interior lighting powerVIJAY KUMARenergy_progress
09/09/2026Fenestration air leakageVIJAY KUMARenergy_progress
09/09/2026Maintenance informationVIJAY KUMARenergy_progress
09/09/2026MeteringVIJAY KUMARenergy_progress
09/09/2026Electric vehicle service equipment requirementsVIJAY KUMARenergy_progress
09/09/2026Permanent certificateVIJAY KUMARenergy_progress
09/09/2026Fenestration and door U-factor and product ratingsVIJAY KUMARenergy_progress
09/09/2026Insulation placement and R valuesVIJAY KUMARenergy_progress
09/09/2026Fenestration areasVIJAY KUMARenergy_progress
09/09/2026Protection of exposed foundation insulationVIJAY KUMARenergy_progress
09/09/2026Air barrier - visual inspectionVIJAY KUMARenergy_progress
09/09/2026Exterior Insulation and Finish Systems (EIFS)VIJAY KUMARspecial
09/09/2026Fire-Resistant Penetrations and JointsVIJAY KUMARspecial
09/09/2026Structural Stability – Alterations of existing buildingsVIJAY KUMARspecial
05/14/2026Fire-Resistant Penetrations and JointsVIJAY KUMARspecial
05/14/2026Structural Stability – Alterations of existing buildingsVIJAY KUMARspecial
05/14/2026Energy Code Compliance InspectionsVIJAY KUMARprogress
05/14/2026Fire-Resistance Rated ConstructionVIJAY KUMARprogress
05/14/2026PreliminaryVIJAY KUMARprogress
05/14/2026Fenestration air leakageVIJAY KUMARenergy_progress
05/14/2026Permanent certificateVIJAY KUMARenergy_progress
05/14/2026Maintenance informationVIJAY KUMARenergy_progress
Latest 25 of 66.
72 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account