← Back
Bungalow colony - cooperatively owned land
217-02 BREEZY POINT BLVD
💬 Discuss this project
1938Year Built
1Stories
A8Building Class
R4Zoning
1,600,000 sfGross Floor Area
1,906Units
LL97 Covered60 Open Violations 2 unresolved · 58 paperwork only ▸FDNY Report ↗
Bungalow colony - cooperatively owned land · Owner of record: BREEZY POINT COOPERATIVE, INC · 12,253,428 sf lot · 0.13 FAR built · Flood zone AE
Locations of Work
ArchitectureFire Protection
Roof1p · 1 filing · 11 docs
Floor 22p · 1 filing · 4 docs
Floor 12p · 2 filings · 15 docs
Cellar3p · 2 filings · 15 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BREEZY POINT COOPERATIVE, INC.1503/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NORMAN C. LOK, PE411/06/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ROCKFISH CUSTOM BUILDERSGeneral Contractor603/21/2026
JOSEPH O'GRADY P & H INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NORMAN C. LOK818107/30/2023
Building Lifecycle
All (52)Filed (4)Permit Issued (3)Signed Off (3)Inspection (5)Objection (30)Special Inspection (7)
04/16/2025
Signed off — Alteration
PLUMBING FOR NEW SECOND FLOOR ADDITION
Q00897183-I1
04/16/2025
Signed off — Alteration
PROPOSED ONE STORY ADDITION
Q00897172-I1
04/09/2025
Signed off — Alteration
TEMPORARY CONSTRUCTION FENCE
Q00897178-I1
03/28/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/26/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/26/2024
Inspection — Certified Sprinkler (PL)-SP-Fixtures (PL)-Finish
Certified
View inspection ↗
11/26/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/26/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/06/2024
Filed — Alteration
PLUMBING FOR NEW SECOND FLOOR ADDITION
Q00897183-P1
09/27/2024
Permit issued — Plumbing
Q00897183-I1-PL
08/12/2024
Permit issued — Construction Fence
Q00897178-I1-FN
08/09/2024
Permit issued — General Construction
Q00897172-I1-GC-CX
09/24/2023
Objection resolved — Addressed
09/24/2023
Objection resolved — Addressed
09/24/2023
Objection resolved — Addressed
09/24/2023
Objection resolved — Addressed
09/24/2023
Objection resolved — Addressed
09/19/2023
Objection resolved — Addressed
09/19/2023
Objection resolved — Addressed
09/19/2023
Objection resolved — Addressed
08/21/2023
Objection resolved — Addressed
08/21/2023
Objection resolved — Addressed
08/21/2023
Special inspection requirement — Fire-Resistance Rated Construction
NORMAN LOK
08/21/2023
Special inspection requirement — Wood – Prefabricated I-Joists
NORMAN LOK
08/21/2023
Special inspection requirement — Permanent certificate
NORMAN LOK
08/21/2023
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
NORMAN LOK
08/21/2023
Special inspection requirement — Structural Wood Frame
NORMAN LOK
08/21/2023
Special inspection requirement — Insulation placement and R values
NORMAN LOK
08/17/2023
Objection raised — Inspections
08/17/2023
Objection raised — Admin
08/17/2023
Objection raised — Inspections
08/17/2023
Objection raised — Fire_Protection
08/17/2023
Objection raised — Fire_Protection
08/17/2023
Objection raised — Structural
08/17/2023
Objection raised — Structural
08/17/2023
Objection raised — Admin
08/17/2023
Objection resolved — Addressed
08/17/2023
Objection resolved — Addressed
08/17/2023
Objection resolved — Addressed
08/17/2023
Objection resolved — Addressed
08/14/2023
Objection raised — Structural
08/11/2023
Objection raised — Admin
08/11/2023
Objection raised — Zoning
08/11/2023
Objection raised — Structural
08/11/2023
Objection raised — Zoning
08/11/2023
Objection raised — Zoning
08/09/2023
Objection resolved — Addressed
08/07/2023
Filed — Alteration
PLUMBING FOR NEW SECOND FLOOR ADDITION
Q00897183-I1
08/04/2023
Objection raised — Other
07/30/2023
Filed — Alteration
PROPOSED ONE STORY ADDITION
Q00897172-I1
07/30/2023
Filed — Alteration
TEMPORARY CONSTRUCTION FENCE
Q00897178-I1
06/28/2023
Special inspection requirement — Final
MOHAMMAD AHEAD
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJOSEPH O'GRADY P & H INC09/27/2024
DOB NOWConstruction FenceSigned-offROCKFISH CUSTOM BUILDERS08/12/2024
DOB NOWGeneral ConstructionSigned-offROCKFISH CUSTOM BUILDERS08/09/2024
1 project · most recent 02/26/2025
General Wiring
FiledStatusContractorScope
02/26/2025CompletePAPPAS & FODERA ELECT'LGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
03/28/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/26/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/26/2024Certified Sprinkler (PL)-SP-Fixtures (PL)-FinishCertifiedView ↗
11/26/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/26/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
08/21/2023Fire-Resistance Rated ConstructionNORMAN LOKprogress
08/21/2023Wood – Prefabricated I-JoistsNORMAN LOKspecial
08/21/2023Permanent certificateNORMAN LOKenergy_progress
08/21/2023Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)NORMAN LOKspecial
08/21/2023Structural Wood FrameNORMAN LOKprogress
08/21/2023Insulation placement and R valuesNORMAN LOKenergy_progress
06/28/2023FinalMOHAMMAD AHEADprogress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/24/2026Q00897178-I1Request digital key ↗
08/24/2026Q00897172-I1Request digital key ↗
08/24/2026Q00897183-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q00897172-I1Open ↗
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/24/2026Q00897172-I1Open ↗
08/13/2026Q00897183-P1Open ↗
08/13/2026Q00897178-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/23/2026Q00897172-I1Open ↗
08/23/2026Q00897172-I1Open ↗
08/23/2026Q00897172-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/23/2026Q00897172-I1Open ↗
08/23/2026Q00897172-I1Open ↗
▸Other Documents3
▸DOB NOWSite Survey: Initial1
08/13/2026Q00897172-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q00897172-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026Q00897172-I1Open ↗