← Back
BuildNYC
One family attached or semi-detached
217 BAY 26 STREET
BROOKLYN · Bath Beach · BIN 3168869
💬 Discuss this project
1955Year Built
2Stories
A5Building Class
R5Zoning
1,674 sfGross Floor Area
1Units
0 Active ViolationsFDNY Report ↗
One family attached or semi-detached · 1,740 sf lot · 0.96 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 27p · 2 filings · 16 docs
Floor 17p · 2 filings · 16 docs
Basement3p · 1 filing · 6 docs
Sub-Basement5p · 2 filings · 16 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/04/2024$992K—JOYFUL STAR GROUP LLC → Private party$593/sf building
04/27/2023$620K—Private party → JOYFUL STAR GROUP LLC$370/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Bassiri609/13/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Ecdesign Studio1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Kle ConstructionGeneral Contractor107/08/2026
Catman PlumbingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Bassiri8394309/13/2023
Building Lifecycle
10/06/2023
Signed off — Alteration
REMOVE ECB VIOLATIONS: 34065017P, 34065018R AND 34209857H; RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00871899-I1
10/05/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
10/03/2023
Signed off — Alteration
REMOVE ECB VIOLATIONS: 34065017P, 34065018R AND 34209857H; RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH PLUMBING WORK: REPLACE KITCHEN AND BATHROOM FIXTURE; NEW COMBI. BOILER ON BASEMENT; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS AP
B00871901-I1
09/21/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
09/13/2023
Filed — Alteration
REMOVE ECB VIOLATIONS: 34065017P, 34065018R AND 34209857H; RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00871899-P2
24 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offKle Construction05/19/2023
DOB NOWPlumbingSigned-offCatman Plumbing05/18/2023
1 project · most recent 05/01/2023
FiledStatusContractorScope
05/01/2023CompleteFraccavento Electric—
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
10/05/2023Pass-Final General Construction Non-Directive 14PassView ↗
09/21/2023Fail-Final General Construction Non-Directive 14FailView ↗
07/12/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/29/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/29/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
09/13/2023Fire-Resistant Penetrations and JointsFARHAD BASSIRI-TEHRANIspecial
09/13/2023Energy Code Compliance InspectionsFARHAD BASSIRI-TEHRANIprogress
09/13/2023Fire-Resistance Rated ConstructionFARHAD BASSIRI-TEHRANIprogress
07/10/2023Fire-Resistant Penetrations and JointsFARHAD BASSIRI-TEHRANIspecial
07/10/2023Energy Code Compliance InspectionsFARHAD BASSIRI-TEHRANIprogress
07/10/2023Fire-Resistance Rated ConstructionFARHAD BASSIRI-TEHRANIprogress
16 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account