← Back
BuildNYC
Two family brick
2173 HOMECREST AVENUE
BROOKLYN · BIN 3199464
💬 Discuss this project
1955Year Built
2Stories
B1Building Class
R5Zoning
1,628 sfGross Floor Area
2Units
Two family brick · 2,117 sf lot · 0.77 FAR built · Flood zone X
Locations of Work
Plumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 211p · 1 filing · 16 docs
Floor 111p · 1 filing · 16 docs
Cellar14p · 1 filing · 16 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/26/2015$600K—Private party → Private party$369/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Arc Consulting Engineers208/14/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Jodom MechanicalPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Arc Consulting Engineers4083208/14/2024
Building Lifecycle
09/16/2024
Signed off — Alteration
JOB FILED TO INSTALL NEW COMBI-BOILERS AT CELLAR AND 2ND FLOOR FOR THIS 2-FAMILY DEWELLING. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
B01057155-I1
09/06/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/29/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/15/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
JAN PEREZ
08/15/2024
Special inspection requirement — Energy Code Compliance Inspections
JAN PEREZ
17 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJodom Mechanical06/20/2024
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
09/06/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/29/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/09/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
08/15/2024Fire-Resistant Penetrations and JointsJAN PEREZspecial
08/15/2024Energy Code Compliance InspectionsJAN PEREZprogress
08/15/2024HVAC-R and service water piping design and insulationJAN PEREZenergy_progress
08/15/2024HVAC-R and service water heating equipmentJAN PEREZenergy_progress
08/15/2024HVAC-R and service water heating system controlsJAN PEREZenergy_progress
08/12/2024Fire-Resistant Penetrations and JointsJAN PEREZspecial
08/12/2024Energy Code Compliance InspectionsJAN PEREZprogress
08/12/2024HVAC-R and service water heating equipmentJAN PEREZenergy_progress
08/12/2024HVAC-R and service water heating system controlsJAN PEREZenergy_progress
08/12/2024HVAC-R and service water piping design and insulationJAN PEREZenergy_progress
16 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account