← Back
BROOKLYN
2177 60 STREET
BROOKLYN · BIN 3429049
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
LL97 Covered0 Open ViolationsFDNY Report ↗
Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionLandscapeCivilGeneralOther
Roof193p · 3 filings · 20 docs
Floor 3185p · 1 filing · 20 docs
Floor 2194p · 2 filings · 20 docs
Floor 1193p · 2 filings · 20 docs
Cellar204p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SUW 49807/08/2026
PLATINUM SERVICES NY1203/22/2026
B T GENERAL BUILDERS603/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/03/2017$950K—— → —— not available
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
S. WIEDER ARCHITECT P.C.2505/02/2024
EYAL LEVITT ARCHITECT PC303/07/2024
ASHRAF CORP305/05/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SPEEDY EXPEDITING5003/21/2026
PLATINUM SERVICES NY603/21/2026
DESIGN STUDIO ASSOCIATES103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
B T GENERAL BUILDERS INCGeneral Contractor1707/08/2026
PLATINUM SERVICES NY LLCGeneral Contractor603/21/2026
PIPING & PLUMBING SOLUTIOFire Protection507/08/2026
SEVA PROPERTY DEVLOPMENTGeneral Contractor407/08/2026
EMPIRE PLUMBING INCPlumbing207/08/2026
CHS CONTRACTING LLCGeneral Contractor203/21/2026
S&R ELECTRICAL & MECHANICElectrical103/22/2026
PIPING PLUMBING SOLUTIOGeneral Contractor103/22/2026
STEPHEN CARNAVALLAElectrical103/21/2026
STAR ELEC'L CONTRACTORS CElectrical103/22/2026
S R ELECTRICAL MECHANIC 005147General Contractor103/22/2026
S WIEDER ARCHITECTGeneral Contractor103/22/2026
YOSEF BLAUElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TECNICO SPECIAL INSPECTIO59392205/02/2024
Building Lifecycle
All (127)Filed (31)Permit Issued (24)Signed Off (11)Violation (9)Inspection (16)Objection (6)Special Inspection (30)
11/18/2025
Violation issued (HPD, closed)
I
05/02/2024
Filed — New Building
MECHANCIAL SPECIFICATIONS FILED SUBSEQUENT TO NB # B00517601
B00517601-A5
03/26/2024
Special inspection requirement — Lighting controls
Jose Lockhart
03/26/2024
Special inspection requirement — Interior lighting power
Jose Lockhart
03/26/2024
Special inspection requirement — Maintenance information
Jose Lockhart
03/26/2024
Special inspection requirement — Lighting in dwelling units
Jose Lockhart
03/26/2024
Special inspection requirement — Energy Code Compliance Inspections
Jose Lockhart
03/26/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jose Lockhart
03/26/2024
Special inspection requirement — Insulation placement and R values
Jose Lockhart
03/26/2024
Special inspection requirement — Fire-Resistance Rated Construction
Jose Lockhart
03/26/2024
Special inspection requirement — Protection of exposed foundation insulation
Jose Lockhart
03/26/2024
Special inspection requirement — Metering
Jose Lockhart
03/26/2024
Special inspection requirement — Air barrier - visual inspection
Jose Lockhart
03/26/2024
Special inspection requirement — Fenestration air leakage
Jose Lockhart
03/26/2024
Special inspection requirement — Electrical motors and elevators
Jose Lockhart
03/26/2024
Special inspection requirement — Fenestration areas
Jose Lockhart
03/26/2024
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
Jose Lockhart
03/26/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Jose Lockhart
03/26/2024
Special inspection requirement — Exterior lighting power
Jose Lockhart
03/26/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Jose Lockhart
03/11/2024
Signed off — New Building
MECHANCIAL SPECIFICATIONS FILED SUBSEQUENT TO NB # B00517601
B00517601-S3
03/11/2024
Objection raised — Other
03/07/2024
Filed — Alteration
PROPOSED INTERIOR BUILDOUT TO EXISTING DAYCARE AS PER PLANS FILED HEREWITH
B00970429-S2
03/07/2024
Special inspection requirement — HVAC-R and service water heating system controls
03/07/2024
Special inspection requirement — Maintenance information
03/07/2024
Special inspection requirement — Energy Code Compliance Inspections
03/07/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
03/07/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/07/2024
Special inspection requirement — HVAC-R and service water heating equipment
03/01/2024
Special inspection requirement — Exterior lighting power
Jose Lockhart
03/01/2024
Special inspection requirement — HVAC-R and service water heating equipment
Jose Lockhart
03/01/2024
Special inspection requirement — HVAC-R and service water heating system controls
Jose Lockhart
03/01/2024
Special inspection requirement — Metering
Jose Lockhart
03/01/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Jose Lockhart
03/01/2024
Special inspection requirement — Lighting controls
Jose Lockhart
02/28/2024
Objection resolved — Addressed
02/24/2024
Signed off — New Building
MECHANCIAL SPECIFICATIONS FILED SUBSEQUENT TO NB # B00517601
B00517601-S4
02/20/2024
Filed — New Building
MECHANCIAL SPECIFICATIONS FILED SUBSEQUENT TO NB # B00517601
B00517601-A2
02/19/2024
Filed — Alteration
PROPOSED INTERIOR BUILDOUT TO EXISTING DAYCARE AS PER PLANS FILED HEREWITH
B00970429-S1
02/12/2024
Filed — New Building
MECHANCIAL SPECIFICATIONS FILED SUBSEQUENT TO NB # B00517601
B00517601-A4
02/11/2024
Signed off — New Building
MECHANCIAL SPECIFICATIONS FILED SUBSEQUENT TO NB # B00517601
B00517601-S1
01/12/2024
Objection resolved — Addressed
01/11/2024
Signed off — New Building
MECHANCIAL SPECIFICATIONS FILED SUBSEQUENT TO NB # B00517601
B00517601-S5
01/11/2024
Signed off — New Building
MECHANCIAL SPECIFICATIONS FILED SUBSEQUENT TO NB # B00517601
B00517601-Z1
01/11/2024
Signed off — New Building
MECHANCIAL SPECIFICATIONS FILED SUBSEQUENT TO NB # B00517601
B00517601-S6
01/09/2024
Filed — New Building
MECHANCIAL SPECIFICATIONS FILED SUBSEQUENT TO NB # B00517601
B00517601-A3
12/29/2023
Objection raised — Other
12/29/2023
Objection raised — Other
12/29/2023
Objection raised — Other
12/13/2023
Filed — Alteration
PROPOSED INTERIOR BUILDOUT TO EXISTING DAYCARE AS PER PLANS FILED HEREWITH
B00970429-I1
11/30/2023
Filed — New Building
MECHANCIAL SPECIFICATIONS FILED SUBSEQUENT TO NB # B00517601
B00517601-P7
11/30/2023
Filed — New Building
MECHANCIAL SPECIFICATIONS FILED SUBSEQUENT TO NB # B00517601
B00517601-P8
11/29/2023
Filed — New Building
MECHANCIAL SPECIFICATIONS FILED SUBSEQUENT TO NB # B00517601
B00517601-A1
11/09/2023
Filed — New Building
MECHANCIAL SPECIFICATIONS FILED SUBSEQUENT TO NB # B00517601
B00517601-P9
11/01/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
10/30/2023
Signed off — Alteration
INSTALLATION OF 300PSF SIDEWALK SHED, OVERHEAD PROTECTION, ROOF PROTECTION AND PIPE SCAFFOLDING AS PER PLANS. ALL EQUIPMENT SHALL COMPLY WITH THE CHAPTER #33 OF THE NYC CODE, NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B07997467-I1
09/08/2023
Signed off — New Building
MECHANCIAL SPECIFICATIONS FILED SUBSEQUENT TO NB # B00517601
B00517601-S2
09/08/2023
Inspection — Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve Test
Certified
View inspection ↗
09/08/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
09/08/2023
Inspection — Pass-Final SD - More than 10 Requested Floors
Pass
View inspection ↗
Latest 60 of 127 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offEMPIRE PLUMBING INC08/31/2023
DOB NOWStandpipeSigned-offEMPIRE PLUMBING INC08/30/2023
DOB NOWCurb CutSigned-offB T GENERAL BUILDERS08/16/2023
DOB NOWPlumbingSigned-offEMPIRE PLUMBING INC08/08/2023
DOB NOWStructuralSigned-offB T GENERAL BUILDERS07/20/2023
DOB NOWConstruction FenceSigned-offB T GENERAL BUILDERS05/18/2023
DOB NOWSprinklersSigned-offEMPIRE PLUMBING INC02/07/2023
DOB NOWGeneral ConstructionPermit IssuedB T GENERAL BUILDERS11/25/2022
DOB NOWMechanical SystemsSigned-offB T GENERAL BUILDERS09/29/2022
DOB NOWSidewalk ShedSigned-offPLATINUM SERVICES NY LLC09/27/2022
DOB NOWSidewalk ShedSigned-offPLATINUM SERVICES NY LLC09/27/2022
DOB NOWGeneral ConstructionPermit IssuedB T GENERAL BUILDERS09/21/2022
DOB NOWStandpipeSigned-offEMPIRE PLUMBING INC08/22/2022
DOB NOWStandpipeSigned-offEMPIRE PLUMBING INC08/22/2022
DOB NOWPlumbingSigned-offEMPIRE PLUMBING INC08/09/2022
DOB NOWFoundationSigned-offB T GENERAL BUILDERS06/29/2022
DOB NOWSupport of ExcavationSigned-offB T GENERAL BUILDERS06/27/2022
DOB NOWStructuralSigned-offB T GENERAL BUILDERS06/14/2022
DOB NOWConstruction FenceSigned-offB T GENERAL BUILDERS05/25/2022
DOB NOWEarth WorkSigned-offB T GENERAL BUILDERS05/25/2022
DOB NOWSupport of ExcavationSigned-offB T GENERAL BUILDERS05/25/2022
DOB NOWFoundationSigned-offSEVA PROPERTY DEVLOPMENT03/24/2022
DOB NOWSupport of ExcavationSigned-offSEVA PROPERTY DEVLOPMENT03/22/2022
DOB NOWConstruction FenceSigned-offCHS CONTRACTING03/09/2022
1 project · most recent 05/02/2024
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/02/2024Signed-offB T GENERAL BUILDERS INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Daikin RXTQ36TBVJUA 36,000 BTU · Vrf Outdoor ×27
4MXL36TVJU 34,400 BTU · Heat Pump Outdoor ×10
3MXL24WMVJU9 24,000 BTU · Heat Pump Outdoor ×8
RX09AXVJU 8,900 BTU · Heat Pump Outdoor ×1
RXTQ48TAVJUA 45,500 BTU · Vrf Outdoor ×1
Rupp Air RARTU-2-I.150-18-10TDDOAS-ERV 66,300 BTU · Rooftop Unit ×1
Ventilation
Daikin VAM470GVJU 500 CFM · Erv ×7
4 projects · most recent 11/30/2023
General Wiring
FiledStatusContractorScope
11/30/2023CompleteILLUMINOUS ELECTRIC CORP.General Wiring
09/11/2023CompleteS&R ELECTRICAL & MECHANICGeneral Wiring
10/09/2022CompleteSTAR ELEC'L CONTRACTORS C—
05/30/2022CompleteHIVOLTS ELECTRICAL INC—
▾Field Inspections (DOB CAP) — 16
DateTypeResultReport
11/01/2023Pass-Final CND-Occupancy InspectionPassView ↗
09/08/2023Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve TestCertifiedView ↗
09/08/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/08/2023Pass-Final SD - More than 10 Requested FloorsPassView ↗
09/07/2023Pass-Final CND-Occupancy InspectionPassView ↗
09/07/2023Pass-Final Curb Cut Non-Directive 14PassView ↗
09/01/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
08/31/2023Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
06/01/2023Pass-Final CND-Occupancy InspectionPassView ↗
04/10/2023Fail-Final CND-Occupancy InspectionFailView ↗
02/21/2023Pass-Final PL - Up to 9 Requested FloorsPassView ↗
12/15/2022Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
09/16/2022Pass-Final PL - UndergroundPassView ↗
08/23/2022Pass-Final PL - UndergroundPassView ↗
08/19/2022Pass-Final PL - UndergroundPassView ↗
08/16/2022Fail-Final PL - UndergroundFailView ↗
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
03/26/2024Electrical motors and elevatorsJose Lockhartenergy_progress
03/26/2024Lighting in dwelling unitsJose Lockhartenergy_progress
03/26/2024Lighting controlsJose Lockhartenergy_progress
03/26/2024Fire-Resistant Penetrations and JointsJose Lockhartspecial
03/26/2024Exterior Insulation and Finish Systems (EIFS)Jose Lockhartspecial
03/26/2024MeteringJose Lockhartenergy_progress
03/26/2024Protection of exposed foundation insulationJose Lockhartenergy_progress
03/26/2024Insulation placement and R valuesJose Lockhartenergy_progress
03/26/2024Fenestration air leakageJose Lockhartenergy_progress
03/26/2024Fenestration and door U-factor and product ratingsJose Lockhartenergy_progress
03/26/2024Exterior lighting powerJose Lockhartenergy_progress
03/26/2024HVAC-R and service water piping design and insulationJose Lockhartenergy_progress
03/26/2024Interior lighting powerJose Lockhartenergy_progress
03/26/2024Maintenance informationJose Lockhartenergy_progress
03/26/2024Fenestration areasJose Lockhartenergy_progress
03/26/2024Air barrier - visual inspectionJose Lockhartenergy_progress
03/26/2024Fire-Resistance Rated ConstructionJose Lockhartprogress
03/26/2024Energy Code Compliance InspectionsJose Lockhartprogress
03/07/2024Fire-Resistant Penetrations and Joints—special
03/07/2024Energy Code Compliance Inspections—progress
03/07/2024Maintenance information—energy_progress
03/07/2024HVAC-R and service water heating system controls—energy_progress
03/07/2024HVAC-R and service water heating equipment—energy_progress
03/07/2024HVAC-R and service water piping design and insulation—energy_progress
03/01/2024Lighting controlsJose Lockhartenergy_progress
Latest 25 of 150.
▾Documents — 306 on file (BIS + DOB NOW)
▸Plans & Drawings31
▸DOB NOWPlans/Sketch31
09/01/2026B00546629-I1Request digital key ↗
08/27/2026B07997467-P1Request digital key ↗
08/27/2026B07997467-I1Request digital key ↗
Showing 3 of 31 on file for this type
▸Applications & Permits8
▸DOB NOWHPD - Permit Notice4
08/13/2026B00517601-P6Open ↗
08/13/2026B00517601-I1Open ↗
08/13/2026B00517601-A1Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION3
06/23/2023322160193Open ↗
06/21/2023322160193Open ↗
05/18/2023322160193Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
02/24/2022340812865Open ↗
▸Zoning, Tax Lot & Property Records14
▸DOB NOWZD1: DOB Zoning Diagram5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸DOB NOWZoning Exhibit form (1-5)5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
05/31/2023322160193Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
05/31/2023322160193Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
05/31/2023322160193Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Seals & Professional Certifications172
▸DOB NOWProgress Inspector Seal & Signature96
09/26/2026B00517601-P4Open ↗
09/26/2026B00517601-P4Open ↗
09/01/2026B00517601-P6Open ↗
Showing 3 of 96 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature44
09/26/2026B00517601-P4Open ↗
09/26/2026B00517601-P4Open ↗
09/26/2026B00517601-P4Open ↗
Showing 3 of 44 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature31
09/01/2026B00546629-I1Open ↗
08/27/2026B07997467-P2Open ↗
08/27/2026B07997467-I1Open ↗
Showing 3 of 31 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
06/29/2021340812865Open ↗
▸Trade Schedules & Equipment6
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸DOB NOWStandpipe Alarms Drawings1
08/26/2026B00517601-I1—
▸Safety & Tenant Protection10
▸DOB NOWStreet Tree Checklist5
08/26/2026B00517601-I1Open ↗
08/26/2026B00517601-P6Open ↗
08/26/2026B00517601-A1Open ↗
Showing 3 of 5 on file for this type
▸BISBPP: STREET TREES SITE PLAN1
02/24/2022340812865Open ↗
▸BISSTREET TREE CHECKLIST1
06/29/2021340812865Open ↗
▸DOB NOWStreet Tree Sign Off1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWStreet Trees Site Plan1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Environmental & Asbestos26
▸DOB NOWOER: Notice to Proceed19
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 19 on file for this type
▸DOB NOWOER: Notice of Satisfaction6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE OF SATISFACTION1
02/24/2022340812865Open ↗
▸Energy Compliance3
▸DOB NOWEN2: As Built Energy Analysis.2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWPreliminary Commissioning Report Certification1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Inspections & Test Reports10
▸DOB NOWSOIL REPORT5
08/13/2026B00517601-S7Open ↗
Showing 1 of 5 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram2
08/13/2026B00517601-S6Open ↗
08/13/2026B00517601-S7Open ↗
▸DOB NOWTR4 Plot Diagram2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY1
02/24/2022340812865Open ↗
▸Approvals, Objections & Sign-offs3
▸BISLETTERS - SUPPORTING DOCUMENTATION3
05/31/2023322160193Open ↗
05/31/2023322160193Open ↗
02/24/2022340812865Open ↗
▸Cost, Insurance & Ownership2
▸DOB NOWCertification by Insurance Broker or Agency1
08/13/2026B00517601-I1Open ↗
▸DOB NOWCertificate of Insurance1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
05/18/2023322160193Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
02/24/2022340812865Open ↗
▸Other Documents19
▸DOB NOWSite Survey: Initial5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISBPP - SUPPORTING DOCUMENTATION2
02/24/2022340812865Open ↗
06/29/2021340812865Open ↗
▸DOB NOWAdjoining Owners Notification2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISPLOT DIAGRAM1
05/31/2023322160193Open ↗
▸BISRECORDS MGMT FEE PAYMENT RECEIPT1
06/29/2021340812865Open ↗
▸DOB NOWFinal Survey1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWAdditional Insured Authorizations1
08/13/2026B00517601-I1Open ↗
▸DOB NOWHPD - Completion Notice1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type