← Back
Garden apartments
218-05 HILLSIDE AVENUE
QUEENS · Queens Village · BIN 4565021
💬 Discuss this project
1950Year Built
3Stories
C9Building Class
R3-2Zoning
45,479 sfGross Floor Area
60Units
Rent Stabilized2 Open Violations ▸FDNY Report ↗
Garden apartments · Owner of record: GOLD SEAL COMPANY · 56,492 sf lot · 0.81 FAR built · Flood zone X
Locations of Work
Plumbing
Cellar1p · 1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
GOLD SEAL COMPANY103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KEMS ENGINEERING AND CONSTRUCTION107/08/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LEWSAN CONSULTING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ANGELO ANDREW INCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GREGORY V. PEROTTO, P.E.947107/08/2021
Building Lifecycle
All (61)Filed (1)Permit Issued (2)Signed Off (1)Violation (53)Inspection (2)Special Inspection (2)
06/12/2025
Violation issued (HPD, closed)
A
01/04/2025
Violation issued (HPD, open)
C
01/04/2025
Violation issued (HPD, closed)
B
01/04/2025
Violation issued (HPD, closed)
B
01/04/2025
Violation issued (HPD, closed)
B
01/04/2025
Violation issued (HPD, closed)
B
03/29/2023
Violation issued (HPD, closed)
A
11/16/2022
Violation issued (HPD, closed)
I
10/26/2022
Violation issued (HPD, closed)
A
10/26/2022
Violation issued (HPD, closed)
A
10/26/2022
Violation issued (HPD, closed)
A
10/26/2022
Violation issued (HPD, closed)
A
10/26/2022
Violation issued (HPD, closed)
A
10/26/2022
Violation issued (HPD, closed)
A
03/18/2022
Signed off — Alteration
Registering laundry room equipment, plumbing and gas piping.
Q00540824-I1
03/04/2022
Violation issued (HPD, closed)
A
01/26/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/21/2022
Inspection — Certified Sprinkler (PL)-Sprinkler-Hydro
Certified
View inspection ↗
01/20/2022
Permit issued — Plumbing
Q00540824-I1-PL
11/29/2021
Violation issued (HPD, closed)
C
11/29/2021
Violation issued (HPD, closed)
A
11/29/2021
Violation issued (HPD, closed)
C
11/29/2021
Violation issued (HPD, closed)
A
11/29/2021
Violation issued (HPD, closed)
A
11/29/2021
Violation issued (HPD, closed)
A
11/29/2021
Violation issued (HPD, closed)
A
07/14/2021
Permit issued — Plumbing
Q00540824-I1-PL
07/08/2021
Filed — Alteration
Registering laundry room equipment, plumbing and gas piping.
Q00540824-I1
07/07/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Gregory Perotto
07/07/2021
Special inspection requirement — Energy Code Compliance Inspections
Steven Bendoraitis
04/15/2021
Violation issued (HPD, closed)
A
05/03/2017
Violation issued (HPD, closed)
B
05/03/2017
Violation issued (HPD, closed)
B
05/03/2017
Violation issued (HPD, closed)
B
01/14/2017
Violation issued (HPD, closed)
B
01/14/2017
Violation issued (HPD, closed)
B
01/14/2017
Violation issued (HPD, closed)
B
03/20/2013
Violation issued (HPD, closed)
B
03/20/2013
Violation issued (HPD, closed)
B
03/20/2013
Violation issued (HPD, closed)
B
11/09/2011
Violation issued (HPD, closed)
B
11/09/2011
Violation issued (HPD, closed)
B
04/06/2010
Violation issued (HPD, closed)
B
04/06/2010
Violation issued (HPD, closed)
B
04/06/2010
Violation issued (HPD, closed)
B
04/06/2010
Violation issued (HPD, closed)
B
04/06/2010
Violation issued (HPD, closed)
B
07/24/2006
Violation issued (HPD, closed)
B
07/24/2006
Violation issued (HPD, closed)
B
07/24/2006
Violation issued (HPD, closed)
B
07/24/2006
Violation issued (HPD, closed)
B
07/24/2006
Violation issued (HPD, closed)
B
07/24/2006
Violation issued (HPD, closed)
C
01/31/2006
Violation issued (HPD, closed)
B
01/31/2006
Violation issued (HPD, closed)
C
01/31/2006
Violation issued (HPD, closed)
B
01/03/2006
Violation issued (HPD, closed)
B
01/03/2006
Violation issued (HPD, closed)
B
01/03/2006
Violation issued (HPD, closed)
B
11/02/2005
Violation issued (HPD, closed)
B
Latest 60 of 61 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offANGELO ANDREW INC01/20/2022
DOB NOWPlumbingSigned-offANGELO ANDREW INC07/14/2021
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
01/26/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/21/2022Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
07/07/2021Fire-Resistant Penetrations and JointsGregory Perottospecial
07/07/2021Energy Code Compliance InspectionsSteven Bendoraitisprogress
▾Documents — 5 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/27/2026Q00540824-I1Request digital key ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q00540824-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/31/2026Q00540824-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/31/2026Q00540824-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q00540824-I1Open ↗