| Owner | Filings | Most Recent |
|---|---|---|
| 135-223 STREET | 16 | 09/15/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 02/02/2026 | $570K | — | — → — | $393/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| NY BUILDING ASSOCIATES INC | 5 | 09/03/2026 |
| PETER CHO ARCHITECTS, PLLC | 1 | 01/23/2026 |
| Representative | Filings | Most Recent |
|---|---|---|
| METRO DESIGN CONSULTANTS INC | 8 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| RISHON HOMES CORP | General Contractor | 4 | 07/29/2026 |
| PLBG P & H INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| NKM ENGINEERING PLLC | 6244 | 4 | 09/03/2026 |
| TRIANGLE INSPECTION & TES | 7495 | 1 | 01/23/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Curb Cut | Permit Issued | RISHON HOMES CORP | 07/28/2026 |
| DOB NOW | Plumbing | Permit Issued | PLBG P & H INC | 03/27/2026 |
| DOB NOW | Earth Work | Permit Issued | RISHON HOMES CORP | 03/17/2026 |
| DOB NOW | General Construction | Permit Issued | RISHON HOMES CORP | 03/16/2026 |
| DOB NOW | Construction Fence | Signed-off | RISHON HOMES CORP | 03/09/2026 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 09/03/2026 | Permit Issued | RISHON HOMES CORP | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Cooper & Hunter CH-48AHU 48,000 BTU · Ahu ×2 CH-60AHU 60,000 BTU · Ahu ×2 CH-N48LCU-230VO 48,000 BTU · Condensing Unit ×2 CH-N60LCU-230VO 60,000 BTU · Condensing Unit ×2 Ventilation Hampton Bay 7114-01 50 CFM · Exhaust Fan ×10 Delta Breeze SMT150 150 CFM · Exhaust Fan ×4 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/03/2026 | Permit Issued | PLBG P & H INC | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/24/2026 | Permit Issued | RONEY ELECTRIC INC | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/03/2026 | Permit Issued | RISHON HOMES CORP | Steel, Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/03/2026 | Permit Issued | RISHON HOMES CORP | Fence |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/03/2026 | Permit Issued | RISHON HOMES CORP | Earthwork |
| Date | Type | Result | Report |
|---|---|---|---|
| 08/28/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 08/04/2026 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 06/12/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 06/12/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 06/09/2026 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 04/21/2026 | Pass-Final General Construction Non-Directive 14 | Pass | View ↗ |
| 04/08/2026 | Certified Storm Drainage-ST-Fixtures-Finish | Certified | View ↗ |
| 04/03/2026 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 09/03/2026 | Permanent certificate | NARESH MAHANGU | energy_progress |
| 09/03/2026 | Insulation placement and R values | NARESH MAHANGU | energy_progress |
| 09/03/2026 | Fenestration air leakage | NARESH MAHANGU | energy_progress |
| 09/03/2026 | Interior lighting power | NARESH MAHANGU | energy_progress |
| 09/03/2026 | Air barrier — testing | NARESH MAHANGU | energy_progress |
| 09/03/2026 | HVAC-R and service water heating system controls | NARESH MAHANGU | energy_progress |
| 09/03/2026 | HVAC-R and service water heating equipment | NARESH MAHANGU | energy_progress |
| 09/03/2026 | HVAC-R and service water piping design and insulation | NARESH MAHANGU | energy_progress |
| 09/03/2026 | Electric vehicle service equipment requirements | NARESH MAHANGU | energy_progress |
| 09/03/2026 | Maintenance information | NARESH MAHANGU | energy_progress |
| 09/03/2026 | Fenestration and door U-factor and product ratings | NARESH MAHANGU | energy_progress |
| 09/03/2026 | Fenestration areas | NARESH MAHANGU | energy_progress |
| 09/03/2026 | Metering | NARESH MAHANGU | energy_progress |
| 09/03/2026 | Ventilation and air distribution system | NARESH MAHANGU | energy_progress |
| 09/03/2026 | Duct leakage testing, insulation and design | NARESH MAHANGU | energy_progress |
| 09/03/2026 | Air barrier - visual inspection | NARESH MAHANGU | energy_progress |
| 09/03/2026 | Structural Wood Frame | NARESH MAHANGU | progress |
| 09/03/2026 | Footing and Foundation | NARESH MAHANGU | progress |
| 09/03/2026 | Fire-Resistance Rated Construction | NARESH MAHANGU | progress |
| 09/03/2026 | Final | PETER CHO | progress |
| 09/03/2026 | Energy Code Compliance Inspections | NARESH MAHANGU | progress |
| 09/03/2026 | Subsurface Investigations (Borings/Test Pits) | Rajasekhar Sakhamuri | special |
| 09/03/2026 | Subgrade Inspections | NARESH MAHANGU | special |
| 09/03/2026 | Structural Steel - High Strength Bolting | NARESH MAHANGU | special |
| 09/03/2026 | Structural Steel - Details | NARESH MAHANGU | special |