← Back
Over six families without stores
218 BAINBRIDGE STREET
BROOKLYN · BIN 3425855
💬 Discuss this project
2020Year Built
4Stories
C1Building Class
R6BZoning
5,722 sfGross Floor Area
8Units
17 Open Violations ▸FDNY Report ↗
Over six families without stores · Owner of record: 216 BAINBRIDGE LLC · 2,797 sf lot · 2.05 FAR built · Flood zone X
Locations of Work
Mechanical
Penthouse1p · 1 filing · 4 docs
Cellar1p · 1 filing · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BETTERBUILT BUILDERS1603/22/2026
216 BAINBRIDGE LLC103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FOCAL POINT ARCHITECTS & ASS.109/04/2023
DOKA ENGINEERING PC102/24/2021
ASIF JAMIL, RA108/06/2020
JEFFREY SANDOR ORLING ARCHITECT102/05/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ADVANCED BUILDERS SERVICES103/21/2026
GREEN STUDIO203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BETTERBUILT BUILDERS INCGeneral Contractor707/08/2026
MANHATTAN D ENTERPRISESGeneral Contractor603/21/2026
L&J PLG & HTG CO OF NY INPlumbing203/22/2026
V. VASS ELECTRIC CORPElectrical103/22/2026
CREATIVE MECHANICALGeneral Contractor103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244109/04/2023
REGIONAL TESTING CORP.394102/24/2021
Building Lifecycle
All (41)Filed (4)Permit Issued (6)Signed Off (4)Violation (23)Inspection (1)Special Inspection (3)
05/11/2026
Violation issued (HPD, open)
A
11/20/2025
Violation issued (HPD, open)
I
06/16/2025
Violation issued (HPD, open)
A
11/29/2024
Violation issued (HPD, open)
I
04/18/2024
Violation issued (HPD, open)
A
11/19/2023
Violation issued (HPD, open)
B
11/19/2023
Violation issued (HPD, open)
B
11/19/2023
Violation issued (HPD, open)
B
11/19/2023
Violation issued (HPD, open)
B
11/06/2023
Signed off — Alteration
Repair all non ST damage to apartment 4B due to a fire; replace damaged exterior stucco walls of the apartment and bulkhead; replace a glass door at roof broke & replace a section of the ceiling in the kitchen; repair all water damage to lower-level apt.
B00928276-I1
11/02/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
10/17/2023
Permit issued — General Construction
B00928276-I1-GC
09/29/2023
Violation issued (HPD, open)
B
09/29/2023
Violation issued (HPD, open)
A
09/29/2023
Violation issued (HPD, open)
A
09/29/2023
Violation issued (HPD, open)
A
09/29/2023
Violation issued (HPD, open)
A
09/29/2023
Violation issued (HPD, open)
A
09/29/2023
Violation issued (HPD, open)
A
09/29/2023
Violation issued (HPD, open)
B
09/04/2023
Filed — Alteration
Repair all non ST damage to apartment 4B due to a fire; replace damaged exterior stucco walls of the apartment and bulkhead; replace a glass door at roof broke & replace a section of the ceiling in the kitchen; repair all water damage to lower-level apt.
B00928276-I1
09/01/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
09/01/2023
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
09/01/2023
Special inspection requirement — Fire-Resistance Rated Construction
NARESH MAHANGU
07/31/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/14/2021
Signed off — Alteration
B00467204-I1
06/14/2021
Signed off — Alteration
B00310541-I1
04/12/2021
Signed off — Alteration
B00381152-I1
03/08/2021
Permit issued — Mechanical Systems
B00467204-I1-MS
02/24/2021
Filed — Alteration
B00467204-I1
10/06/2020
Violation issued (ECB, closed)
Construction
09/18/2020
Violation issued (ECB, closed)
Construction
08/27/2020
Violation issued (ECB, closed)
Construction
08/27/2020
Violation issued (ECB, closed)
Construction
08/17/2020
Permit issued — Construction Fence
B00310541-I1-FN
08/07/2020
Permit issued — Supported Scaffold
B00381152-I1-SH
08/07/2020
Permit issued — Supported Scaffold
B00381152-I1-SF
08/06/2020
Filed — Alteration
B00381152-I1
08/06/2020
Violation issued (ECB, closed)
Unknown
02/12/2020
Permit issued — Construction Fence
B00310541-I1-FN
02/05/2020
Filed — Alteration
B00310541-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offBETTERBUILT BUILDERS10/17/2023
DOB NOWMechanical SystemsSigned-offBETTERBUILT BUILDERS03/08/2021
DOB NOWConstruction FenceSigned-offBETTERBUILT BUILDERS08/17/2020
DOB NOWSupported ScaffoldSigned-offMANHATTAN D ENTERPRISES08/07/2020
DOB NOWSupported ScaffoldSigned-offMANHATTAN D ENTERPRISES08/07/2020
DOB NOWConstruction FenceSigned-offBETTERBUILT BUILDERS02/12/2020
BISPLISSUEDL&J PLG & HTG CO OF NY IN07/15/2021
BIS—ISSUEDBETTERBUILT BUILDERS INC12/16/2020
BIS—ISSUEDBETTERBUILT BUILDERS INC11/13/2020
BISSPISSUEDMETFLOW FIRE CONTROL LLC08/14/2020
BIS—ISSUEDBETTERBUILT BUILDERS INC08/13/2020
BIS—ISSUEDBETTERBUILT BUILDERS INC08/13/2020
BISPLISSUEDL&J PLG & HTG CO OF NY IN07/22/2020
BIS—ISSUEDBETTERBUILT BUILDERS INC06/16/2020
BIS—ISSUEDBETTERBUILT BUILDERS INC06/16/2020
BISEQISSUEDBETTERBUILT BUILDERS INC06/10/2020
3 projects · most recent 05/10/2021
General Wiring
FiledStatusContractorScope
05/10/2021CompleteFOSTER ELEC'L SVC., INC.General Wiring
09/17/2020CompleteFOSTER ELEC'L SVC., INC.—
07/14/2020CompleteV. VASS ELECTRIC CORP—
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
11/02/2023Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
09/01/2023Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
09/01/2023Energy Code Compliance InspectionsNARESH MAHANGUprogress
09/01/2023Fire-Resistance Rated ConstructionNARESH MAHANGUprogress
▾Documents — 167 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch - Mechanical Systems1
09/01/2026B00467204-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence1
09/02/2026B00310541-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Supported Scaffold1
09/02/2026B00381152-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sidewalk Shed1
09/02/2026B00381152-I1Request digital key ↗
▸DOB NOWPlans/Sketch1
08/26/2026B00928276-I1Request digital key ↗
▸Applications & Permits39
▸BISPLAN / WORK APPROVAL APPLICATION29
10/29/2021321779580Open ↗
10/08/2021321779580Open ↗
09/21/2021321836288Open ↗
Showing 3 of 29 on file for this type
▸BISWORK PERMIT APPLICATION7
08/14/2020321764756Open ↗
07/22/2020321779580Open ↗
07/22/2020321764756Open ↗
Showing 3 of 7 on file for this type
▸BISBPP-5 - Authorization to the Department of Transportation1
12/15/2020340793369Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
09/29/2020321779580Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
09/09/2020321779580Open ↗
▸Zoning, Tax Lot & Property Records7
▸BISZONING DIAGRAM3
10/08/2021321779580Open ↗
02/05/2020321779580Open ↗
11/08/2019321779580Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
11/08/2019321779580Open ↗
▸BISVERIFY TAX LOT1
08/10/2021321779580Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
11/16/2021321779580Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
11/08/2019321779580Open ↗
▸Seals & Professional Certifications16
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
05/14/2020321779580Open ↗
05/14/2020321779580Open ↗
11/08/2019321779580Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/01/2026B00467204-I1Open ↗
08/26/2026B00928276-I1Open ↗
08/13/2026B00310541-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
11/28/2018321764756Open ↗
11/28/2018321764756Open ↗
11/28/2018321764756Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
12/15/2020340793369Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
11/28/2018321764756Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/28/2026B00928276-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026B00928276-I1Open ↗
▸Trade Schedules & Equipment17
▸BISSCHEDULE B - PLUMBING8
10/29/2021321779580Open ↗
05/14/2021321779580Open ↗
05/10/2021321779580Open ↗
Showing 3 of 8 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
11/28/2018321764756Open ↗
02/13/2018321779580Open ↗
▸BISFIRE ALARM TEST2
10/27/2021321779580Open ↗
10/27/2021321779580Open ↗
▸BISFIRE ALARM/SIGNAL SYSTEM (FA) SIGNOFF1
11/10/2021321779580Open ↗
▸BISSPRINKLER INSP REPORT : FP-851
10/27/2021321779580Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA1
11/04/2021321779580Open ↗
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
10/12/2021321779580Open ↗
▸BISDETECTOR:CARBON MONOXIDE-CERT.OF INSTALL1
10/27/2021321779580Open ↗
▸Safety & Tenant Protection4
▸BISBPP: STREET TREES SITE PLAN1
12/15/2020340793369Open ↗
▸BISSTREET TREE CHECKLIST1
12/15/2020340793369Open ↗
▸BISSTREET TREE SIGNOFF1
08/10/2021321779580Open ↗
▸DOB NOWTenant Protection Plan1
08/13/2026B00381152-I1Open ↗
▸Energy Compliance9
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
08/10/2021321779580Open ↗
09/30/2020321779580Open ↗
06/09/2020321779580Open ↗
▸BISAS-BUILT ENERGY ANALYSIS2
09/21/2021321779580Open ↗
08/10/2021321779580Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
05/14/2020321779580Open ↗
11/27/2018321800155Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026B00467204-I1Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026B00467204-I1Open ↗
▸Inspections & Test Reports24
▸BISTECHNICAL REPORT: RESPONSIBILITY11
10/29/2021321779580Open ↗
10/22/2021321779580Open ↗
09/21/2021321779580Open ↗
Showing 3 of 11 on file for this type
▸BISTR3: CONCRETE DESIGN MIX TECHNICAL REPORT4
06/17/2020321779580Open ↗
06/17/2020321779580Open ↗
06/17/2020321779580Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX4
06/09/2020321779580Open ↗
06/09/2020321779580Open ↗
06/09/2020321779580Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER2
09/21/2021321779580Open ↗
06/11/2020321779580Open ↗
▸BISTR2: CONCRETE TEST CYLINDERS TECHNICAL REPORT1
06/17/2020321779580Open ↗
▸BISSOIL REPORT1
11/08/2019321779580Open ↗
▸BISSUBSURFACE / SOILS INVESTIGATION (BORINGS/TEST PITS)1
10/29/2021321779580Open ↗
▸Approvals, Objections & Sign-offs16
▸BISLETTERS - SUPPORTING DOCUMENTATION9
10/29/2021321779580Open ↗
10/08/2021321779580Open ↗
10/08/2021321779580Open ↗
Showing 3 of 9 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE4
12/23/2020321779580Open ↗
03/04/2019321779580Open ↗
08/31/2018321779580Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
11/09/2021321925477Open ↗
06/07/2021321764756Open ↗
▸BISHOUSE CONNECTION SIGNOFF1
11/04/2020321779580Open ↗
▸Cost, Insurance & Ownership5
▸BISPROJECT SPECIFIC GENERAL LIABILITY INSURANCE3
06/17/2020321779580Open ↗
06/17/2020321779580Open ↗
06/17/2020321779580Open ↗
▸BISPROJECT-SPECIFIC GL INSURANCE2
07/08/2020321779580Open ↗
06/10/2020321779580Open ↗
▸Filing & Intake Forms19
▸BISADDITIONAL INFORMATION10
10/29/2021321779580Open ↗
10/08/2021321779580Open ↗
10/06/2021321779580Open ↗
Showing 3 of 10 on file for this type
▸BISEFILING COVER SHEET7
03/28/2019321925477Open ↗
11/27/2018321836288Open ↗
11/27/2018321764756Open ↗
Showing 3 of 7 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
12/15/2020340793369Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
12/15/2020340793369Open ↗
▸Other Documents6
▸BISPLOT DIAGRAM2
11/08/2019321779580Open ↗
11/08/2019321779580Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
11/08/2019321779580Open ↗
▸BISEXPLORATORY ANALYSIS FOR UNDERPINNING(REPORT SUBMITTED)1
10/22/2021321779580Open ↗
▸BISSITE CONNECTION:DEP1
11/08/2019321779580Open ↗
▸BISUnknown1
03/09/2020321779580Open ↗