← Back
Two family converted from one family
219 EAST 48 STREET
MANHATTAN · East Midtown-Turtle Bay · BIN 1038004
💬 Discuss this project
1899Year Built
3Stories
B3Building Class
R8BZoning
2,400 sfGross Floor Area
2Units
Two family converted from one family · 1,272 sf lot · 1.89 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbing
Roof10p · 2 filings · 20 docs
Floor 411p · 2 filings · 20 docs
Floor 342p · 4 filings · 20 docs
Floor 237p · 4 filings · 20 docs
Floor 120p · 3 filings · 20 docs
Cellar41p · 4 filings · 20 docs
Sub-Basement24p · 2 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/15/2022$3.3M—— → —$1,385/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BODNAR ARCHITECT PC503/01/2024
EMTG CONSULTANTS INC912/19/2023
BLUE SKY DESIGN, INC.107/12/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BODNAR ARCHITECTURE P C2003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRI CONTRACTING INCGeneral Contractor1203/21/2026
JBUILD LLCGeneral Contractor303/21/2026
CBB PLUMBING CORPPlumbing107/08/2026
FRANKIE PLBG & HTG L.L.CPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BLUE SKY DESIGN, INC.1908107/12/2023
EMTG CONSULTANTS4222105/17/2023
Building Lifecycle
All (43)Filed (15)Permit Issued (7)Signed Off (2)Inspection (5)Special Inspection (14)
03/04/2024
Special inspection requirement — Fire-Resistance Rated Construction
Theodore Bodnar
03/04/2024
Special inspection requirement — Final
Theodore Bodnar
03/01/2024
Filed — Alteration
Construction of interior non-load bearing partitions, doors, built-in cabinetry, floor, ceiling & wall finishes and installation of plumbing fixtures in CEL, BAS, 1st-3rd floors of existing one family dwelling. No change in occupancy, use or egress.
M08014573-P2
03/01/2024
Filed — Alteration
Construction of interior non-load bearing partitions, doors, built-in cabinetry, floor, ceiling & wall finishes and installation of plumbing fixtures in CEL, BAS, 1st-3rd floors of existing one family dwelling. No change in occupancy, use or egress.
M08014573-P3
03/01/2024
Special inspection requirement — Final
Theodore Bodnar
03/01/2024
Special inspection requirement — Fire-Resistance Rated Construction
Theodore Bodnar
02/12/2024
Signed off — Alteration
Installation of plumbing and gas fixtures in cellar, basement, 1st, 2nd and 3rd floor of existing on family dwelling. No change in occupancy, use or egress.
M00873730-I1
02/05/2024
Signed off — Alteration
Removal of interior non-load bearing partitions, doors, built-in cabinetry, floor and wall finishes, convenience stair, and plumbing fixtures in the cellar, basement, 1st-3rd floor for existing one-family dwelling. No change in occupancy use or egress.
M08019056-I1
12/19/2023
Filed — Alteration
Installation of plumbing and gas fixtures in cellar, basement, 1st, 2nd and 3rd floor of existing on family dwelling. No change in occupancy, use or egress.
M00873730-P7
12/09/2023
Filed — Alteration
Installation of plumbing and gas fixtures in cellar, basement, 1st, 2nd and 3rd floor of existing on family dwelling. No change in occupancy, use or egress.
M00873730-P6
12/05/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/27/2023
Filed — Alteration
Installation of plumbing and gas fixtures in cellar, basement, 1st, 2nd and 3rd floor of existing on family dwelling. No change in occupancy, use or egress.
M00873730-P5
11/27/2023
Filed — Alteration
Installation of plumbing and gas fixtures in cellar, basement, 1st, 2nd and 3rd floor of existing on family dwelling. No change in occupancy, use or egress.
M00873730-P4
11/13/2023
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
07/18/2023
Filed — Alteration
Installation of plumbing and gas fixtures in cellar, basement, 1st, 2nd and 3rd floor of existing on family dwelling. No change in occupancy, use or egress.
M00873730-P3
07/17/2023
Permit issued — Structural
M08014573-S2-ST
07/14/2023
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
07/12/2023
Filed — Alteration
Construction of interior non-load bearing partitions, doors, built-in cabinetry, floor, ceiling & wall finishes and installation of plumbing fixtures in CEL, BAS, 1st-3rd floors of existing one family dwelling. No change in occupancy, use or egress.
M08014573-S2
07/07/2023
Filed — Alteration
Installation of plumbing and gas fixtures in cellar, basement, 1st, 2nd and 3rd floor of existing on family dwelling. No change in occupancy, use or egress.
M00873730-P2
06/27/2023
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
06/27/2023
Special inspection requirement — Structural Steel - Welding
ANDREW RENFROE
06/27/2023
Special inspection requirement — Final
ANDREW RENFROE
06/27/2023
Special inspection requirement — Masonry
ANDREW RENFROE
06/27/2023
Special inspection requirement — Post-installed Anchors
ANDREW RENFROE
06/27/2023
Special inspection requirement — Structural Steel - Details
ANDREW RENFROE
06/27/2023
Special inspection requirement — Structural Steel - High Strength Bolting
ANDREW RENFROE
06/08/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
05/26/2023
Filed — Alteration
Installation of plumbing and gas fixtures in cellar, basement, 1st, 2nd and 3rd floor of existing on family dwelling. No change in occupancy, use or egress.
M00873730-P1
05/26/2023
Permit issued — Plumbing
M00873730-I1-PL
05/19/2023
Permit issued — Mechanical Systems
M00875927-I1-MS
05/17/2023
Filed — Alteration
Installation of plumbing and gas fixtures in cellar, basement, 1st, 2nd and 3rd floor of existing on family dwelling. No change in occupancy, use or egress.
M00873730-I1
05/17/2023
Filed — Alteration
Installation of Mechanical Units with Mechanical Ductwork in Cellar, Basement, 1st, 2nd, 3rd floor and Roof of existing one family dwelling. No change in occupancy use or egress.
M00875927-I1
05/16/2023
Special inspection requirement — Mechanical Systems
Shahram Lotfi
05/16/2023
Special inspection requirement — Energy Code Compliance Inspections
Shahram Lotfi
05/16/2023
Special inspection requirement — Heating Systems
Shahram Lotfi
05/16/2023
Special inspection requirement — Final
Shahram Lotfi
05/01/2023
Permit issued — General Construction
M08014573-S1-GC
04/24/2023
Filed — Alteration
Construction of interior non-load bearing partitions, doors, built-in cabinetry, floor, ceiling & wall finishes and installation of plumbing fixtures in CEL, BAS, 1st-3rd floors of existing one family dwelling. No change in occupancy, use or egress.
M08014573-S1
03/30/2023
Permit issued — General Construction
M08014573-I1-GC
12/13/2022
Permit issued — Plumbing
M08019056-I1-PL
11/02/2022
Permit issued — General Construction
M08014573-I1-GC
10/26/2022
Filed — Alteration
Removal of interior non-load bearing partitions, doors, built-in cabinetry, floor and wall finishes, convenience stair, and plumbing fixtures in the cellar, basement, 1st-3rd floor for existing one-family dwelling. No change in occupancy use or egress.
M08019056-I1
10/26/2022
Filed — Alteration
Construction of interior non-load bearing partitions, doors, built-in cabinetry, floor, ceiling & wall finishes and installation of plumbing fixtures in CEL, BAS, 1st-3rd floors of existing one family dwelling. No change in occupancy, use or egress.
M08014573-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedTRI CONTRACTING INC07/17/2023
DOB NOWPlumbingSigned-offCBB PLUMBING CORP05/26/2023
DOB NOWMechanical SystemsPermit IssuedTRI CONTRACTING INC05/19/2023
DOB NOWGeneral ConstructionPermit IssuedTRI CONTRACTING INC05/01/2023
DOB NOWGeneral ConstructionPermit IssuedTRI CONTRACTING INC03/30/2023
DOB NOWPlumbingSigned-offFRANKIE PLBG & HTG L.L.C12/13/2022
DOB NOWGeneral ConstructionPermit IssuedJBUILD LLC11/02/2022
1 project · most recent 05/17/2023
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
05/17/2023Permit IssuedTRI CONTRACTING INCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric Mitsubishi - PEFY-P08NMAU-E4 8,000 BTU · Vrf Indoor ×2
MITSUBISHI - MXZ-SM48NAMHZ-U1 48,000 BTU · Vrf Outdoor ×1
Mitsubishi - MXZ-SM36NAMHZ-U1 36,000 BTU · Condensing Unit ×1
Mitsubishi - P12NMAU-E4 12,000 BTU ×1
Mitsubishi - PEFY-P24NMAU-E4 24,000 BTU · Vrf Indoor ×1
Mitsubishi - PKFY-P06NLMU-E.TH 6,000 BTU · Vrf Indoor ×1
Mitsubishi - PVFY-P12NAMU-E1 12,000 BTU · Vrf Indoor ×1
Mitsubishi - PVFY-P24NAMU-E1 24,000 BTU · Vrf Indoor ×1
1 project · most recent 01/17/2024
General Wiring
FiledStatusContractorScope
01/17/2024CompleteDANUBE ELECTRIC CO., INC.General Wiring
1 project · most recent 03/01/2024
Steel
FiledStatusContractorScope
03/01/2024Permit IssuedTRI CONTRACTING INCSteel
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
12/05/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/13/2023Pass-Final PL - Up to 9 Requested FloorsPassView ↗
07/14/2023Pass-Final PL - Up to 9 Requested FloorsPassView ↗
06/27/2023Pass-Final PL - UndergroundPassView ↗
06/08/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
03/04/2024Fire-Resistance Rated ConstructionTheodore Bodnarprogress
03/04/2024FinalTheodore Bodnarprogress
03/01/2024FinalTheodore Bodnarprogress
03/01/2024Fire-Resistance Rated ConstructionTheodore Bodnarprogress
06/27/2023Structural Steel - WeldingANDREW RENFROEspecial
06/27/2023FinalANDREW RENFROEprogress
06/27/2023MasonryANDREW RENFROEspecial
06/27/2023Post-installed AnchorsANDREW RENFROEspecial
06/27/2023Structural Steel - DetailsANDREW RENFROEspecial
06/27/2023Structural Steel - High Strength BoltingANDREW RENFROEspecial
05/16/2023Mechanical SystemsShahram Lotfispecial
05/16/2023Energy Code Compliance InspectionsShahram Lotfiprogress
05/16/2023Heating SystemsShahram Lotfispecial
05/16/2023FinalShahram Lotfiprogress
▾Documents — 57 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch15
09/01/2026M08019056-I1Request digital key ↗
08/31/2026M00875927-I1Request digital key ↗
08/28/2026M00873730-I1Request digital key ↗
Showing 3 of 15 on file for this type
▸Seals & Professional Certifications27
▸DOB NOWDPL-1: Design Professional Seal & Signature15
08/28/2026M00873730-P7Open ↗
08/28/2026M00873730-P6Open ↗
08/28/2026M00873730-P5Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
08/30/2026M08014573-S2Open ↗
08/30/2026M08014573-S2Open ↗
08/30/2026M08014573-S2Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
08/30/2026M08014573-S2Open ↗
08/25/2026M08014573-P2Open ↗
08/25/2026M08014573-I1Open ↗
Showing 3 of 5 on file for this type
▸Environmental & Asbestos15
▸DOB NOWDEP ACP-5: Asbestos Assessment Report15
08/28/2026M00873730-P4Open ↗
08/28/2026M00873730-P7Open ↗
08/28/2026M00873730-P6Open ↗
Showing 3 of 15 on file for this type