← Back
Two family brick
22-02 128 STREET
QUEENS · College Point · BIN 4099657
💬 Discuss this project
1920Year Built
2Stories
B1Building Class
R4-1Zoning
1,760 sfGross Floor Area
2Units
2 Open Violations ▸FDNY Report ↗
Two family brick · 1,306 sf lot · 1.35 FAR built · Flood zone X
Locations of Work
Architecture
Roof1p · 1 filing · 9 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SYNERGIC DESIGN ARCHITECTS105/07/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ACCORD POWER ELECTRIC LLCElectrical203/22/2026
ACCORD POWER INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SYNERGIC DESIGN LLC8561105/07/2025
Building Lifecycle
All (32)Filed (1)Permit Issued (1)Signed Off (1)Violation (10)Objection (14)Special Inspection (5)
10/27/2025
Signed off — Alteration
Installation of 9.35 kw solar energy system on roof. No change of occupancy, use or egress.
Q01217130-I1
09/03/2025
Violation issued (ECB, closed)
Unknown
08/07/2025
Permit issued — Solar
Q01217130-I1-SL
07/18/2025
Objection resolved — Addressed
07/01/2025
Objection resolved — Addressed
06/20/2025
Objection resolved — Addressed
06/10/2025
Objection resolved — Addressed
06/10/2025
Objection resolved — Addressed
06/10/2025
Objection resolved — Addressed
06/10/2025
Objection resolved — Addressed
05/16/2025
Objection raised — Admin
05/16/2025
Objection raised — Admin
05/16/2025
Objection raised — Scope
05/16/2025
Objection raised — Zoning
05/16/2025
Objection raised — Zoning
05/16/2025
Objection raised — Admin
05/16/2025
Objection raised — Fire_Protection
05/07/2025
Filed — Alteration
Installation of 9.35 kw solar energy system on roof. No change of occupancy, use or egress.
Q01217130-I1
04/28/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Malathi Ananthakrishnan
04/28/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Malathi Ananthakrishnan
04/28/2025
Special inspection requirement — Energy Code Compliance Inspections
Malathi Ananthakrishnan
04/28/2025
Special inspection requirement — Final
Malathi Ananthakrishnan
04/28/2025
Special inspection requirement — Air barrier - visual inspection
Malathi Ananthakrishnan
10/19/2018
Violation issued (HPD, closed)
B
10/19/2018
Violation issued (HPD, closed)
B
10/19/2018
Violation issued (HPD, open)
C
09/21/2018
Violation issued (HPD, closed)
B
09/21/2018
Violation issued (HPD, open)
C
09/21/2018
Violation issued (HPD, closed)
B
09/21/2018
Violation issued (HPD, closed)
B
09/21/2018
Violation issued (HPD, closed)
B
09/21/2018
Violation issued (HPD, closed)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offACCORD POWER INC08/07/2025
2 projects · most recent 09/16/2025
General Wiring
FiledStatusContractorScope
09/16/2025CompletePOWER ON ELECTRICAL SERVGeneral Wiring
08/07/2025CompleteACCORD POWER ELECTRIC LLC—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
04/28/2025Fire-Resistant Penetrations and JointsMalathi Ananthakrishnanspecial
04/28/2025Structural Stability – Alterations of existing buildingsMalathi Ananthakrishnanspecial
04/28/2025Energy Code Compliance InspectionsMalathi Ananthakrishnanprogress
04/28/2025FinalMalathi Ananthakrishnanprogress
04/28/2025Air barrier - visual inspectionMalathi Ananthakrishnanenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/20/2026Q01217130-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/24/2026Q01217130-I1Open ↗
08/24/2026Q01217130-I1Open ↗
08/24/2026Q01217130-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/24/2026Q01217130-I1Open ↗
08/24/2026Q01217130-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/20/2026Q01217130-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/20/2026Q01217130-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01217130-I1Open ↗