← Back
One story retail building
22-20 36 AVENUE
QUEENS · BIN 4004261
💬 Discuss this project
1966Year Built
1Stories
K1Building Class
R5Zoning
11,086 sfGross Floor Area
1Units
0 Open Violations
One story retail building · Owner of record: RAMZI REALTY CORP · 22,290 sf lot · 0.5 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
RAMZI REALTY CORP103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ALFRED MIERZEJEWSKI ARCHITECT308/30/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
FOCAL POINT DESIGN & CONST. INC.403/21/2026
BUILD TEAM203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ZHONG WANG CONSTRUCTION SGeneral Contractor303/21/2026
SAMFRIENDS DEVEL & CONSTGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HSU & ASSOCIATES8025208/16/2023
Building Lifecycle
All (27)Filed (3)Permit Issued (2)Signed Off (1)Violation (5)Inspection (1)Objection (7)Special Inspection (8)
09/05/2023
Objection raised — Fire_Protection
09/05/2023
Objection raised — Inspections
09/05/2023
Objection raised — Inspections
09/05/2023
Objection raised — Other
09/05/2023
Objection raised — Admin
08/31/2023
Permit issued — Mechanical Systems
Q00920188-I1-GC-CX
08/30/2023
Filed — Alteration
Filing for plumbing Fire Suppression shutoff valve. no change in egress and use.
Q00920188-S1
08/24/2023
Objection raised — Fire_Protection
08/24/2023
Objection resolved — Addressed
08/16/2023
Filed — Alteration
Filing for plumbing Fire Suppression shutoff valve. no change in egress and use.
Q00920188-I1
08/16/2023
Special inspection requirement — Mechanical Systems
Chih Hsu
08/16/2023
Special inspection requirement — Final
Chih Hsu
06/22/2022
Signed off — Alteration
Q00575330-I1
06/17/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
04/13/2022
Permit issued — General Construction
Q00575330-I1-GC
08/13/2021
Filed — Alteration
Q00575330-I1
08/11/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Chih Hsu
08/11/2021
Special inspection requirement — Energy Code Compliance Inspections
Alfred Mierzejewski
08/11/2021
Special inspection requirement — Air barrier continuity plan testing
Alfred Mierzejewski
08/11/2021
Special inspection requirement — Air barrier — testing
Alfred Mierzejewski
08/11/2021
Special inspection requirement — Maintenance information
Alfred Mierzejewski
08/11/2021
Special inspection requirement — Air barrier - visual inspection
Alfred Mierzejewski
09/14/2010
Violation issued (ECB, closed)
Unknown
09/14/2010
Violation issued (ECB, closed)
Unknown
07/03/2008
Violation issued (ECB, closed)
Construction
04/06/1995
Violation issued (ECB, closed)
Construction
04/06/1995
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedZHONG WANG CONSTRUCTION S08/31/2023
DOB NOWGeneral ConstructionSigned-offSAMFRIENDS DEVEL & CONST04/13/2022
BISMHISSUED30-07 NEWTOWN CORP04/16/2008
1 project · most recent 08/30/2023
Ventilation Systems
FiledStatusContractorScope
08/30/2023Permit IssuedZHONG WANG CONSTRUCTION SVentilation Systems
1 project · most recent 08/30/2023
Gas
FiledStatusContractorScope
08/30/2023——Gas
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
06/17/2022Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
08/16/2023Mechanical SystemsChih Hsuspecial
08/16/2023FinalChih Hsuprogress
08/11/2021Fire-Resistant Penetrations and JointsChih Hsuspecial
08/11/2021Energy Code Compliance InspectionsAlfred Mierzejewskiprogress
08/11/2021Air barrier continuity plan testingAlfred Mierzejewskienergy_progress
08/11/2021Air barrier — testing Alfred Mierzejewskienergy_progress
08/11/2021Maintenance informationAlfred Mierzejewskienergy_progress
08/11/2021Air barrier - visual inspectionAlfred Mierzejewskienergy_progress
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/27/2026Q00575330-I1Request digital key ↗
08/24/2026Q00920188-I1Request digital key ↗
08/14/2026Q00920188-S1Request digital key ↗
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature6
08/29/2026Q00920188-I1Open ↗
08/25/2026Q00575330-I1Open ↗
08/25/2026Q00575330-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026Q00920188-I1Open ↗
08/13/2026Q00920188-S1Open ↗
08/13/2026Q00575330-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/29/2026Q00920188-I1Open ↗
08/25/2026Q00575330-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00575330-I1Open ↗