← Back
Two family brick
22-72 47 STREET
QUEENS · BIN 4014549
💬 Discuss this project
1965Year Built
2Stories
B1Building Class
R4Zoning
1,840 sfGross Floor Area
2Units
2 Open Violations ▸
Two family brick · 2,006 sf lot · 0.92 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Roof2p · 1 filing · 20 docs
Floor 33p · 2 filings · 20 docs
Floor 2
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MOONK ENTERPRISE203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/18/2024$1.2M—— → —$652/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DAVI ARCHITECTURE, PC606/17/2026
AUTOMATED DESIGN ENGINEERING, PLLC410/09/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MOONK ENTERPRISE INCGeneral Contractor504/09/2026
DYNAMIC PLBNG & SPRKR CORFire Protection107/08/2026
PEAK PLUMBING SOLUTIONS LLCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DAVI ARCHITECTURE, PC5168506/17/2026
AUTOMATED DESIGN CONSULTA895410/09/2025
C.M. TESTING LABORATORY,1352208/03/2025
Building Lifecycle
All (63)Filed (10)Permit Issued (6)Signed Off (2)Violation (2)Inspection (7)Objection (6)Special Inspection (30)
07/24/2026
Objection resolved — Open
07/16/2026
Objection raised — Other
07/14/2026
Objection raised — Cost
07/14/2026
Objection resolved — Addressed
07/06/2026
Objection resolved — Addressed
06/30/2026
Objection raised — Other
06/17/2026
Filed — Alteration CO
Q01369251-I1
04/30/2026
Special inspection requirement — Fire-Resistance Rated Construction
Benedetto Davi
04/30/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Benedetto Davi
01/30/2026
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
01/20/2026
Signed off — Alteration
Proposed 3rd floor of an existing 2-story 2-family brick dwelling. No change to use, egress, nor occupancy. Change in bulk.
Q01100981-S2
12/18/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
12/11/2025
Signed off — Alteration
Proposed 3rd floor of an existing 2-story 2-family brick dwelling. No change to use, egress, nor occupancy. Change in bulk.
Q01100981-S3
10/22/2025
Inspection — Pass-Final SP - Up to 3 Requested Floors
Pass
View inspection ↗
10/09/2025
Filed — Alteration
Proposed 3rd floor of an existing 2-story 2-family brick dwelling. No change to use, egress, nor occupancy. Change in bulk.
Q01100981-P5
10/08/2025
Special inspection requirement — Sprinkler Systems
Gregory Mortman
10/07/2025
Filed — Alteration
Proposed 3rd floor of an existing 2-story 2-family brick dwelling. No change to use, egress, nor occupancy. Change in bulk.
Q01100981-P6
10/07/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Gregory Mortman
10/07/2025
Special inspection requirement — HVAC-R and service water heating equipment
Gregory Mortman
10/07/2025
Special inspection requirement — Maintenance information
Gregory Mortman
10/07/2025
Special inspection requirement — Mechanical Systems
Gregory Mortman
10/07/2025
Special inspection requirement — Shutoff dampers
Gregory Mortman
10/07/2025
Special inspection requirement — Ventilation and air distribution system
Gregory Mortman
10/07/2025
Special inspection requirement — Sprinkler Systems
Gregory Mortman
10/07/2025
Special inspection requirement — HVAC-R and service water heating system controls
Gregory Mortman
10/07/2025
Special inspection requirement — Energy Code Compliance Inspections
Gregory Mortman
10/07/2025
Special inspection requirement — Final
Gregory Mortman
08/22/2025
Special inspection requirement — Insulation placement and R values
Benedetto Davi
08/22/2025
Special inspection requirement — Structural Steel - Details
JOHN SEMIOLI
08/22/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Benedetto Davi
08/22/2025
Special inspection requirement — Structural Cold-Formed Steel
JOHN SEMIOLI
08/22/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
JOHN SEMIOLI
08/22/2025
Special inspection requirement — Final
Benedetto Davi
08/22/2025
Special inspection requirement — Lighting in dwelling units
Benedetto Davi
08/22/2025
Special inspection requirement — Lighting controls
Benedetto Davi
08/22/2025
Special inspection requirement — Fenestration areas
Benedetto Davi
08/22/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Benedetto Davi
08/14/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/07/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Benedetto Davi
08/07/2025
Special inspection requirement — Energy Code Compliance Inspections
Benedetto Davi
08/07/2025
Special inspection requirement — HVAC-R and service water heating equipment
Benedetto Davi
08/07/2025
Special inspection requirement — Maintenance information
Benedetto Davi
08/07/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Benedetto Davi
08/07/2025
Special inspection requirement — HVAC-R and service water heating system controls
Benedetto Davi
08/05/2025
Filed — Alteration
Proposed 3rd floor of an existing 2-story 2-family brick dwelling. No change to use, egress, nor occupancy. Change in bulk.
Q01100981-P3
08/03/2025
Filed — Alteration
Proposed 3rd floor of an existing 2-story 2-family brick dwelling. No change to use, egress, nor occupancy. Change in bulk.
Q01100981-P4
08/03/2025
Special inspection requirement — Structural Cold-Formed Steel
JOHN SEMIOLI
07/16/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/16/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/11/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
07/08/2025
Permit issued — Sprinklers
Q01100981-S3-EW-SP
06/13/2025
Permit issued — General Construction
Q01100981-I1-GC-CX
05/29/2025
Violation issued (ECB, open)
Construction
05/29/2025
Violation issued (ECB, open)
Construction
05/23/2025
Permit issued — Plumbing
Q01100981-S1-PL
04/22/2025
Filed — Alteration
Proposed 3rd floor of an existing 2-story 2-family brick dwelling. No change to use, egress, nor occupancy. Change in bulk.
Q01100981-P1
04/14/2025
Filed — Alteration
Proposed 3rd floor of an existing 2-story 2-family brick dwelling. No change to use, egress, nor occupancy. Change in bulk.
Q01100981-S3
04/07/2025
Permit issued — Mechanical Systems
Q01100981-S2-MS
04/03/2025
Filed — Alteration
Proposed 3rd floor of an existing 2-story 2-family brick dwelling. No change to use, egress, nor occupancy. Change in bulk.
Q01100981-S2
04/03/2025
Permit issued — Structural
Q01100981-I1-GC-CX
Latest 60 of 63 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offCITYWIDE PLBG, HTG &SPRKL07/08/2025
DOB NOWGeneral ConstructionSigned-offMOONK ENTERPRISE INC06/13/2025
DOB NOWPlumbingSigned-offPEAK PLUMBING SOLUTIONS L05/23/2025
DOB NOWMechanical SystemsSigned-offMOONK ENTERPRISE INC04/07/2025
DOB NOWStructuralSigned-offMOONK ENTERPRISE INC04/03/2025
DOB NOWStructuralSigned-offMOONK ENTERPRISE INC02/28/2025
1 project · most recent 10/09/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/09/2025Signed-offMOONK ENTERPRISE INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MLZ-KP12NA2 15,400 BTU · Vrf Indoor ×6
MLZ-KP09NA2 12,000 BTU · Fan Coil Indoor ×4
MXZ-3C30NAHZ4 28,400 BTU · Heat Pump Outdoor ×4
MLZ-KY06NA 7,200 BTU · Fan Coil Indoor ×2
MSZ-FS12NA 12,300 BTU · Fan Coil Indoor ×2
MSZ-FS15NA 16,000 BTU · Fan Coil Indoor ×2
MXZ-3C24NAHZ4 22,000 BTU · Heat Pump Outdoor ×2
Cadet CEC163TW 5,115 BTU · Electric Heater ×2
Ventilation
Broan BCSEK130WW 121 CFM · Kitchen Exhaust ×2
Panasonic FV-0511VHL1 81 CFM · Exhaust Fan ×2
1 project · most recent 10/09/2025
FiledStatusContractorScope
10/09/2025Signed-offDYNAMIC PLBNG & SPRKR COR20 heads
1 project · most recent 10/09/2025
Gas Water/Sanitary
FiledStatusContractorScope
10/09/2025Signed-offPEAK PLUMBING SOLUTIONS LGas, Water/Sanitary
1 project · most recent 11/04/2025
General Wiring
FiledStatusContractorScope
11/04/2025CompleteDELTA POWER ELECTRICALGeneral Wiring
1 project · most recent 10/09/2025
Steel
FiledStatusContractorScope
10/09/2025Signed-offDYNAMIC PLBNG & SPRKR CORSteel
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
01/30/2026Pass-Final General Construction Non-Directive 14PassView ↗
12/18/2025Fail-Final General Construction Non-Directive 14FailView ↗
10/22/2025Pass-Final SP - Up to 3 Requested FloorsPassView ↗
08/14/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/16/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/16/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/11/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 45
DateRequirementInspectorRole
04/30/2026Fire-Resistance Rated ConstructionBenedetto Daviprogress
04/30/2026Fire-Resistant Penetrations and JointsBenedetto Davispecial
10/08/2025Sprinkler SystemsGregory Mortmanspecial
10/07/2025HVAC-R and service water piping design and insulationGregory Mortmanenergy_progress
10/07/2025HVAC-R and service water heating equipmentGregory Mortmanenergy_progress
10/07/2025Maintenance informationGregory Mortmanenergy_progress
10/07/2025Mechanical SystemsGregory Mortmanspecial
10/07/2025Shutoff dampersGregory Mortmanenergy_progress
10/07/2025Ventilation and air distribution systemGregory Mortmanenergy_progress
10/07/2025Sprinkler SystemsGregory Mortmanspecial
10/07/2025HVAC-R and service water heating system controlsGregory Mortmanenergy_progress
10/07/2025Energy Code Compliance InspectionsGregory Mortmanprogress
10/07/2025FinalGregory Mortmanprogress
08/22/2025Insulation placement and R valuesBenedetto Davienergy_progress
08/22/2025Structural Steel - DetailsJOHN SEMIOLIspecial
08/22/2025Fire-Resistant Penetrations and JointsBenedetto Davispecial
08/22/2025Structural Cold-Formed SteelJOHN SEMIOLIspecial
08/22/2025Structural Stability – Alterations of existing buildingsJOHN SEMIOLIspecial
08/22/2025FinalBenedetto Daviprogress
08/22/2025Lighting in dwelling unitsBenedetto Davienergy_progress
08/22/2025Lighting controlsBenedetto Davienergy_progress
08/22/2025Fenestration areasBenedetto Davienergy_progress
08/22/2025Fenestration and door U-factor and product ratingsBenedetto Davienergy_progress
08/07/2025Fire-Resistant Penetrations and JointsBenedetto Davispecial
08/07/2025Energy Code Compliance InspectionsBenedetto Daviprogress
Latest 25 of 45.
▾Documents — 63 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/21/2026Q01100981-S1Request digital key ↗
08/21/2026Q01100981-I1Request digital key ↗
08/21/2026Q01100981-S2Request digital key ↗
Showing 3 of 10 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026Q01100981-P4Open ↗
08/13/2026Q01100981-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/15/2026Q01369251-I1Open ↗
▸Seals & Professional Certifications33
▸DOB NOWSpecial Inspector Seal & Signature13
09/23/2026Q01100981-P6Open ↗
09/02/2026Q01100981-S3Open ↗
09/01/2026Q01100981-I1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWProgress Inspector Seal & Signature10
09/01/2026Q01100981-I1Open ↗
09/01/2026Q01100981-I1Open ↗
09/01/2026Q01100981-P3Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/21/2026Q01100981-I1Open ↗
08/21/2026Q01100981-P6Open ↗
08/21/2026Q01100981-P5Open ↗
Showing 3 of 10 on file for this type
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/21/2026Q01100981-I1Open ↗
08/21/2026Q01100981-P6Open ↗
08/21/2026Q01100981-P5Open ↗
Showing 3 of 9 on file for this type
▸Other Documents8
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026Q01100981-P4Open ↗
08/13/2026Q01100981-I1Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026Q01100981-I1Open ↗
08/13/2026Q01100981-P4Open ↗
▸DOB NOWPlot Diagram2
08/13/2026Q01100981-P4Open ↗
08/13/2026Q01100981-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/15/2026Q01369251-I1Open ↗
▸DOB NOWFinal Survey1
08/15/2026Q01369251-I1Open ↗