← Back
Two stories - detached, small or mid-size
220-05 138 ROAD
QUEENS · BIN 4282118
💬 Discuss this project
1950Year Built
1Stories
A1Building Class
R3XZoning
1,100 sfGross Floor Area
1Units
4 Open Violations ▸FDNY Report ↗
Two stories - detached, small or mid-size · Owner of record: INWOOD HOME LLC · 6,250 sf lot · 0.18 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction7p · 1 filing · 20 docs
Floor 1Under Construction7p · 1 filing · 20 docs
CellarUnder Construction9p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/10/2025$662K—— → —$602/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
D&E BUILD EVERGREEN INC.311/10/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
METRO DESIGN CONSULTANTS INC603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
J&J DESIGNS INCGeneral Contractor504/09/2026
SUPERIOR PLUMBING & HEATINGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244211/10/2025
TRIANGLE INSPECTION & TES7495111/10/2025
Building Lifecycle
All (63)Filed (3)Permit Issued (4)Violation (14)Objection (12)Special Inspection (30)
06/03/2026
Permit issued — Plumbing
Q01280779-S2-PL
01/21/2026
Permit issued — Mechanical Systems
Q01280779-I1-FO-EA
01/21/2026
Permit issued — Mechanical Systems
Q01280779-I1-GC-CX
01/05/2026
Objection resolved — Addressed
01/05/2026
Objection resolved — Addressed
12/12/2025
Objection raised — Energy
12/12/2025
Objection resolved — Addressed
12/09/2025
Objection resolved — Addressed
12/09/2025
Objection resolved — Addressed
11/22/2025
Objection resolved — Addressed
11/19/2025
Objection raised — Other
11/19/2025
Objection raised — Admin
11/19/2025
Objection raised — Admin
11/10/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
FILED HEREWITH PLUMBING WORK TYPE IN CONJUNCTION WITH APPLICATION #Q01280779-I1 & GARAGE NB APPLICATION # Q01303489-I1.
Q01280779-S2
11/10/2025
Objection raised — Cost
11/10/2025
Objection raised — Admin
11/05/2025
Permit issued — Construction Fence
Q01280779-S1-FN
10/29/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
FILED HEREWITH PLUMBING WORK TYPE IN CONJUNCTION WITH APPLICATION #Q01280779-I1 & GARAGE NB APPLICATION # Q01303489-I1.
Q01280779-I1
10/29/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
FILED HEREWITH PLUMBING WORK TYPE IN CONJUNCTION WITH APPLICATION #Q01280779-I1 & GARAGE NB APPLICATION # Q01303489-I1.
Q01280779-S1
10/23/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
10/23/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
NARESH MAHANGU
10/23/2025
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
Rajasekhar Sakhamuri
10/23/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
10/23/2025
Special inspection requirement — HVAC-R and service water heating equipment
NARESH MAHANGU
10/23/2025
Special inspection requirement — HVAC-R and service water heating system controls
NARESH MAHANGU
10/23/2025
Special inspection requirement — Maintenance information
NARESH MAHANGU
10/23/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
NARESH MAHANGU
09/02/2025
Special inspection requirement — Structural Steel - High Strength Bolting
NARESH MAHANGU
09/02/2025
Special inspection requirement — Subgrade Inspections
NARESH MAHANGU
09/02/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
09/02/2025
Special inspection requirement — Structural Steel - Details
NARESH MAHANGU
09/02/2025
Special inspection requirement — Final
PETER CHO
09/02/2025
Special inspection requirement — Footing and Foundation
NARESH MAHANGU
09/02/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
09/02/2025
Special inspection requirement — Fire-Resistance Rated Construction
NARESH MAHANGU
09/02/2025
Special inspection requirement — Structural Wood Frame
NARESH MAHANGU
09/02/2025
Special inspection requirement — Fenestration air leakage
NARESH MAHANGU
09/02/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
NARESH MAHANGU
09/02/2025
Special inspection requirement — Metering
NARESH MAHANGU
09/02/2025
Special inspection requirement — Fenestration areas
NARESH MAHANGU
09/02/2025
Special inspection requirement — Insulation placement and R values
NARESH MAHANGU
09/02/2025
Special inspection requirement — Duct leakage testing, insulation and design
NARESH MAHANGU
09/02/2025
Special inspection requirement — HVAC-R and service water heating system controls
NARESH MAHANGU
09/02/2025
Special inspection requirement — HVAC-R and service water heating equipment
NARESH MAHANGU
09/02/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
09/02/2025
Special inspection requirement — Air barrier — testing
NARESH MAHANGU
09/02/2025
Special inspection requirement — Maintenance information
NARESH MAHANGU
09/02/2025
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
09/02/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
NARESH MAHANGU
06/23/2021
Violation issued (ECB, closed)
Construction
12/30/2020
Violation issued (ECB, closed)
Construction
09/21/2020
Violation issued (ECB, closed)
Construction
01/25/2020
Violation issued (ECB, closed)
Construction
11/22/2019
Violation issued (ECB, closed)
Construction
10/19/2019
Violation issued (ECB, open)
Construction
08/01/2019
Violation issued (ECB, closed)
Construction
05/17/2019
Violation issued (ECB, closed)
Construction
02/28/2019
Violation issued (ECB, closed)
Construction
12/31/2018
Violation issued (ECB, closed)
Construction
12/12/2018
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Latest 60 of 63 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedSUPERIOR PLUMBING & HEATING06/03/2026
DOB NOWMechanical SystemsPermit IssuedJ&J DESIGNS INC01/21/2026
DOB NOWMechanical SystemsPermit IssuedJ&J DESIGNS INC01/21/2026
DOB NOWConstruction FencePermit IssuedJ&J DESIGNS INC11/05/2025
1 project · most recent 11/10/2025
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
11/10/2025Permit IssuedJ&J DESIGNS INCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Goodman GLXS3BN3610AA 36,000 BTU · Condensing Unit ×1
GLXS3BN4210AA 42,000 BTU · Condensing Unit ×1
Heating
Goodman AMST42CU1300AA 42,000 BTU · Ahu ×1
AMST48CU1300AA 48,000 BTU · Ahu ×1
Ventilation
Hampton Bay 7114-01 50 CFM · Exhaust Fan ×9
Delta Breeze SMT150 150 CFM · Exhaust Fan ×2
1 project · most recent 11/10/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
11/10/2025Permit IssuedSUPERIOR PLUMBING & HEATIGas, Storm, Water/Sanitary
1 project · most recent 11/10/2025
Steel Wood
FiledStatusContractorScope
11/10/2025Permit IssuedSUPERIOR PLUMBING & HEATISteel, Wood
1 project · most recent 11/10/2025
Earthwork
FiledStatusContractorScope
11/10/2025Permit IssuedSUPERIOR PLUMBING & HEATIEarthwork
▾Special Inspection Requirements (DOB NOW) — 41
DateRequirementInspectorRole
10/23/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
10/23/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationNARESH MAHANGUspecial
10/23/2025Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesRajasekhar Sakhamurispecial
10/23/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
10/23/2025HVAC-R and service water heating equipmentNARESH MAHANGUenergy_progress
10/23/2025HVAC-R and service water heating system controlsNARESH MAHANGUenergy_progress
10/23/2025Maintenance informationNARESH MAHANGUenergy_progress
10/23/2025HVAC-R and service water piping design and insulationNARESH MAHANGUenergy_progress
09/02/2025Structural Steel - High Strength BoltingNARESH MAHANGUspecial
09/02/2025Subgrade InspectionsNARESH MAHANGUspecial
09/02/2025Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
09/02/2025Structural Steel - DetailsNARESH MAHANGUspecial
09/02/2025FinalPETER CHOprogress
09/02/2025Footing and FoundationNARESH MAHANGUprogress
09/02/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
09/02/2025Fire-Resistance Rated ConstructionNARESH MAHANGUprogress
09/02/2025Structural Wood FrameNARESH MAHANGUprogress
09/02/2025Fenestration air leakageNARESH MAHANGUenergy_progress
09/02/2025Fenestration and door U-factor and product ratingsNARESH MAHANGUenergy_progress
09/02/2025MeteringNARESH MAHANGUenergy_progress
09/02/2025Fenestration areasNARESH MAHANGUenergy_progress
09/02/2025Insulation placement and R valuesNARESH MAHANGUenergy_progress
09/02/2025Duct leakage testing, insulation and designNARESH MAHANGUenergy_progress
09/02/2025HVAC-R and service water heating system controlsNARESH MAHANGUenergy_progress
09/02/2025HVAC-R and service water heating equipmentNARESH MAHANGUenergy_progress
Latest 25 of 41.
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/18/2026Q01280779-S1Request digital key ↗
08/18/2026Q01280779-I1Request digital key ↗
08/18/2026Q01280779-S2Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01280779-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q01280779-I1Open ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature5
08/28/2026Q01280779-S2Open ↗
08/28/2026Q01280779-S2Open ↗
08/25/2026Q01280779-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/28/2026Q01280779-S2Open ↗
08/28/2026Q01280779-S2Open ↗
08/25/2026Q01280779-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/18/2026Q01280779-S1Open ↗
08/18/2026Q01280779-I1Open ↗
08/18/2026Q01280779-S2Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/18/2026Q01280779-I1Open ↗
08/18/2026Q01280779-S2Open ↗
▸Inspections & Test Reports2
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q01280779-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026Q01280779-I1Open ↗
▸Other Documents4
▸DOB NOWSite Survey: Initial1
08/13/2026Q01280779-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01280779-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q01280779-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/18/2026Q01280779-I1Open ↗