← Back
Miscellaneous educational facility
220-12 LINDEN BOULEVARD
QUEENS · BIN 4274388
💬 Discuss this project
1948Year Built
1Stories
W9Building Class
R3-2Zoning
18,500 sfGross Floor Area
2Units
22 Open Violations 15 unresolved · 7 paperwork only ▸FDNY Report ↗
Miscellaneous educational facility · Owner of record: DEEPER LIFE BIBLE CHURCH, INC. · 10,800 sf lot · 1.71 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 114p · 2 filings · 14 docs
Cellar13p · 2 filings · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DEEPER LIFE BIBLE CHURCH807/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/16/2023$1.7M—CAMBRIA HEIGHTS GOSPEL CHAPEL, INC. → DEEPER LIFE BIBLE CHURCH, INC.$94/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
STEWART ENGINEERING SERVICES, PLLC309/05/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ALL PURPOSE SERVICES INCGeneral Contractor303/21/2026
V'S CREATIVE DESIGNGeneral Contractor207/08/2026
RAMDEEN, BALDATHElectrical103/21/2026
REDROVAN ELIASElectrical103/21/2026
PLUMB-IT MECHANICAL INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
STEWART ENGINEERING SERVI2506309/05/2023
Building Lifecycle
All (63)Filed (3)Permit Issued (4)Signed Off (1)Violation (38)Objection (8)Special Inspection (9)
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/11/2025
Permit issued — Mechanical Systems
Q00898249-I1-MS
04/16/2025
Permit issued — Plumbing
Q00898263-I1-PL
04/05/2025
Signed off — Alteration CO
Demolish the interior non-structural walls.
Q00898249-S1
11/21/2024
Permit issued — Mechanical Systems
Q00898249-I1-GC
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/13/2024
Objection resolved — Addressed
06/11/2024
Objection resolved — Addressed
05/23/2024
Objection resolved — Addressed
02/23/2024
Permit issued — Structural
Q00898249-S1-ST
02/22/2024
Objection resolved — Addressed
09/05/2023
Filed — Alteration CO
Demolish the interior non-structural walls.
Q00898249-S1
09/05/2023
Special inspection requirement — Demolition
EGAR STEWART
09/05/2023
Special inspection requirement — Final
EGAR STEWART
08/03/2023
Objection raised — Admin
08/03/2023
Objection raised — Accessibility
08/03/2023
Objection raised — Accessibility
08/03/2023
Objection raised — Scope
07/17/2023
Filed — Alteration CO
Demolish the interior non-structural walls.
Q00898249-I1
07/17/2023
Filed — Alteration
Install new bathrooms on the first floor
Q00898263-I1
07/14/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
EGAR STEWART
07/14/2023
Special inspection requirement — Energy Code Compliance Inspections
EGAR STEWART
07/14/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
EGAR STEWART
07/14/2023
Special inspection requirement — HVAC-R and service water heating system controls
EGAR STEWART
07/14/2023
Special inspection requirement — Electrical motors and elevators
EGAR STEWART
07/14/2023
Special inspection requirement — HVAC-R and service water heating equipment
EGAR STEWART
07/14/2023
Special inspection requirement — Maintenance information
EGAR STEWART
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/08/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/06/2018
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/09/2017
Violation issued (ECB, open)
Boilers
02/24/2017
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/08/2016
Violation issued (ECB, closed)
Construction
04/08/2016
Violation issued (ECB, open)
Construction
04/08/2016
Violation issued (ECB, closed)
Construction
10/01/2015
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/10/2015
Violation issued (FDNY_NOV, closed)
05/04/2015
Violation issued (ECB, open)
Construction
05/04/2015
Violation issued (ECB, open)
Construction
03/03/2015
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/15/2014
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/01/2013
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/31/2009
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/22/2008
Violation issued (ECB, closed)
Construction
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/18/2000
Violation issued (FDNY_NOV, closed)
10/28/1999
Violation issued (FDNY_NOV, closed)
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/31/1995
Violation issued (FDNY_NOV, closed)
11/09/1994
Violation issued (FDNY_NOV, closed)
04/13/1993
Violation issued (FDNY_NOV, closed)
12/31/1992
Violation issued (ECB, closed)
Construction
12/01/1992
Violation issued (FDNY_NOV, closed)
02/16/1990
Violation issued (FDNY_NOV, closed)
11/13/1989
Violation issued (ECB, open)
Public Assembly
06/14/1989
Violation issued (ECB, open)
Public Assembly
Latest 60 of 63 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedV'S CREATIVE DESIGN07/11/2025
DOB NOWPlumbingPermit IssuedJVR PLBG AND HEATING INC04/16/2025
DOB NOWMechanical SystemsPermit IssuedV'S CREATIVE DESIGN11/21/2024
DOB NOWStructuralSigned-offALL PURPOSE SERVICES INC02/23/2024
BISFPISSUEDMASTER FIRE SYSTEMS, INC05/22/2015
BISOTISSUEDE&J ALL SEASONS CONSTRUCT08/27/2014
BISPLISSUEDMARCO POLO PLBG & HTG INC05/20/2014
BISOTISSUEDMARCO POLO DESIGN CORP07/25/2013
BISPLISSUEDPFEIFFER P,HTG,SPKL CONT01/24/2013
BISOTISSUEDMARCO POLO DESIGN CORP01/24/2013
BISOTISSUEDMARCO POLO DESIGN CORP09/27/2011
BISMHISSUEDMARCO POLO DESIGN CORP06/20/2011
BISOTISSUEDMARCO POLO DESIGN CORP06/20/2011
BISPLISSUEDTHE PLUMBING COMPANY INC05/24/2011
BISPLISSUEDS.J. VISION & SON P & H01/31/2011
BIS—ISSUEDGOLDSMITH CONST CORP04/06/2010
BISOTISSUEDGOLDSMITH CONST CORP07/08/2009
BIS—ISSUEDGOLDSMITH CONST CORP06/03/2009
BISPLISSUEDCITY TESTING & PLUMBING I04/14/2009
BISOTISSUEDGOLDSMITH CONSTRUCTION CORP.10/09/2008
BISFPISSUEDIDEAL FIRE CONTROL11/22/1994
BISOTISSUEDISS INT. SERVICE SYST. INC09/22/1994
BISEQISSUEDSIGMA PLG. & HTNG. DBA J.A.L08/23/1994
1 project · most recent 09/05/2023
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
09/05/2023Permit IssuedV'S CREATIVE DESIGNHeating and Air Conditioning Systems
Heat / Cool
Goodman CAPF4860D6 60,000 BTU · Split System ×4
GSX140481 48,000 BTU · Condensing Unit ×4
Trane YHC063A3EHA1R 60,000 BTU · Rooftop Unit ×1
1 project · most recent 07/17/2023
Water/Sanitary
FiledStatusContractorScope
07/17/2023Permit IssuedJVR PLBG AND HEATING INCWater/Sanitary
1 project · most recent 02/13/2024
General Wiring
FiledStatusContractorScope
02/13/2024Permit IssuedCLAIRMONT ELEC'L CONTR'GGeneral Wiring
1 project · most recent 09/05/2023
FiledStatusContractorScope
09/05/2023Permit IssuedV'S CREATIVE DESIGN1 scope_items
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
09/05/2023DemolitionEGAR STEWARTspecial
09/05/2023FinalEGAR STEWARTprogress
07/14/2023Fire-Resistant Penetrations and JointsEGAR STEWARTspecial
07/14/2023Energy Code Compliance InspectionsEGAR STEWARTprogress
07/14/2023HVAC-R and service water piping design and insulationEGAR STEWARTenergy_progress
07/14/2023HVAC-R and service water heating system controlsEGAR STEWARTenergy_progress
07/14/2023Electrical motors and elevatorsEGAR STEWARTenergy_progress
07/14/2023HVAC-R and service water heating equipmentEGAR STEWARTenergy_progress
07/14/2023Maintenance informationEGAR STEWARTenergy_progress
▾Documents — 108 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/24/2026Q00898263-I1Request digital key ↗
08/24/2026Q00898249-S1Request digital key ↗
08/24/2026Q00898249-I1Request digital key ↗
▸Applications & Permits13
▸BISPLAN / WORK APPROVAL APPLICATION7
04/09/2015421011782Open ↗
10/08/2013420905211Open ↗
02/25/2010420143794Open ↗
Showing 3 of 7 on file for this type
▸BISWORK PERMIT APPLICATION5
06/05/2015421011782Open ↗
11/04/2013420905211Open ↗
11/12/2010420143794Open ↗
Showing 3 of 5 on file for this type
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
12/03/2013420905211Open ↗
▸Seals & Professional Certifications27
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION16
07/20/2015421011782Open ↗
06/05/2015421011782Open ↗
04/09/2015421011782Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/24/2026Q00898263-I1Open ↗
08/24/2026Q00898263-I1Open ↗
08/24/2026Q00898249-S1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026Q00898249-I1Open ↗
08/13/2026Q00898249-S1Open ↗
08/13/2026Q00898263-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/24/2026Q00898263-I1Open ↗
08/24/2026Q00898249-S1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
10/08/2013420905211Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
10/08/2013420905211Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
10/08/2013420905211Open ↗
▸Trade Schedules & Equipment14
▸BISSELF-CERT PLUMBING NOTICE6
03/16/2011420143794Open ↗
03/01/2011420143794Open ↗
02/24/2011420143794Open ↗
Showing 3 of 6 on file for this type
▸BISSPRINKLER INSP REPORT : FP-854
03/01/2011420143794Open ↗
02/24/2011420143794Open ↗
02/24/2011420143794Open ↗
Showing 3 of 4 on file for this type
▸BISEQUIPMENT USE PERMITS2
12/03/2013420905211Open ↗
12/03/2013420905211Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
12/03/2013420905211Open ↗
▸BISSCHEDULE B - PLUMBING1
02/25/2010420143794Open ↗
▸Safety & Tenant Protection4
▸BISSTREET TREE CHECKLIST3
06/19/2009420033430Open ↗
06/03/2008410114772Open ↗
06/03/2008410114772Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026Q00898249-I1Open ↗
▸Environmental & Asbestos6
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'3
02/25/2010420143794Open ↗
10/22/2009420096853Open ↗
09/08/2008410114772Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
11/04/2013420905211Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
06/19/2009420033430Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q00898249-I1Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
11/08/2013420905211Open ↗
10/08/2013420905211Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
11/08/2013420905211Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER2
10/22/2009420096853Open ↗
10/22/2009420096853Open ↗
▸Approvals, Objections & Sign-offs13
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST6
07/20/2015421011782Open ↗
12/03/2013420905211Open ↗
06/10/2011420143794Open ↗
Showing 3 of 6 on file for this type
▸BISADMINISTRATIVE OBJECTIONS5
10/08/2013420905211Open ↗
02/25/2010420143794Open ↗
10/22/2009420096853Open ↗
Showing 3 of 5 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION2
08/24/2010420033430Open ↗
03/12/2009410114772Open ↗
▸Cost, Insurance & Ownership11
▸BISCOST AFFIDAVIT11
07/20/2015421011782Open ↗
04/09/2015421011782Open ↗
11/08/2013420905211Open ↗
Showing 3 of 11 on file for this type
▸Filing & Intake Forms9
▸BISEFILING COVER SHEET6
04/09/2015421011782Open ↗
10/08/2013420905211Open ↗
02/25/2010420143794Open ↗
Showing 3 of 6 on file for this type
▸BISADDITIONAL INFORMATION3
08/27/2010420096853Open ↗
09/24/2008410114772Open ↗
09/08/2008410114772Open ↗
▸Other Documents3
▸BISFIRE SUPP ANSUL APPROVL: FD-FSS1
07/20/2015421011782Open ↗
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
10/09/2008410114772Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026Q00898249-I1Open ↗