| Firm | Filings | Most Recent |
|---|---|---|
| Askon Architects | 4 | 10/08/2026 |
| Ebds | 5 | 10/02/2026 |
| Synergic Design Architects | 1 | 05/18/2026 |
| EE Building Services | 1 | 10/02/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| KNF Services Crop | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| ZK Development | General Contractor | 3 | 09/25/2026 |
| Dynamic Plumbing & Sprinkler | Fire Protection | 2 | 10/04/2026 |
| Accord Power | General Contractor | 1 | 07/08/2026 |
| ZK Development | Scaffold | 1 | 04/09/2026 |
| 24 Seven Plumbing | Plumbing | 1 | 07/08/2026 |
| Kishan Plumbing | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| HRF Services | 5616 | 6 | 10/08/2026 |
| Synergic Design | 8561 | 1 | 05/18/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Sprinklers | Permit Issued | Dynamic Plumbing & Sprinkler | 09/29/2026 |
| DOB NOW | Curb Cut | Signed-off | ZK Development | 09/24/2026 |
| DOB NOW | Solar | Signed-off | Accord Power | 05/21/2026 |
| DOB NOW | Sprinklers | Permit Issued | Citywide Plumbing, Heating & Sprinkler | 03/31/2026 |
| DOB NOW | Plumbing | Signed-off | 24 Seven Plumbing | 03/04/2026 |
| DOB NOW | Plumbing | Signed-off | N and S Plumbing | 02/18/2026 |
| DOB NOW | Mechanical Systems | Signed-off | ZK Development | 01/29/2026 |
| DOB NOW | Construction Fence | Signed-off | ZK Development | 10/10/2025 |
| DOB NOW | General Construction | Permit Issued | ZK Development | 09/16/2025 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 10/08/2026 | Signed-off | ZK Development | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric MXZ-SM36NAMHZ2-U1 3 tons · Heat Pump Outdoor ×1 MXZ-SM42NAMHZ2-U1 35 tons · Vrf Outdoor ×1 Ventilation Fantech FIT 120 E 130 CFM ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/08/2026 | Permit Issued | Dynamic Plumbing & Sprinkler | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/08/2026 | Signed-off | Kishan Plumbing | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/19/2026 | Complete | Accord Power Electric | — |
| 02/05/2026 | Complete | Roney Electric | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/08/2026 | Permit Issued | The Plumbing and Sprinkler | Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/08/2026 | Permit Issued | The Plumbing and Sprinkler | Fence |
| Date | Type | Result | Report |
|---|---|---|---|
| 10/02/2026 | Fail-Final Curb Cut Non-Directive 14 | Fail | View ↗ |
| 09/28/2026 | Pass-Final SP - Up to 3 Requested Floors | Pass | View ↗ |
| 09/23/2026 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 03/04/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 03/04/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 09/30/2026 | Sprinkler Systems | SHAHRIAR QUAYYUM | special |
| 09/30/2026 | Fire-Resistant Penetrations and Joints | SHAHRIAR QUAYYUM | special |
| 09/22/2026 | Subgrade Inspections | SHAHRIAR QUAYYUM | special |
| 09/22/2026 | Final | SHAHRIAR QUAYYUM | progress |
| 09/22/2026 | Concrete - Cast-In-Place | SHAHRIAR QUAYYUM | special |
| 09/22/2026 | Excavations - Sheeting, Shoring, and Bracing | SHAHRIAR QUAYYUM | special |
| 09/22/2026 | Fire-Resistant Penetrations and Joints | SHAHRIAR QUAYYUM | special |
| 09/22/2026 | Masonry | SHAHRIAR QUAYYUM | special |
| 09/22/2026 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | SHAHRIAR QUAYYUM | special |
| 09/22/2026 | Energy Code Compliance Inspections | SHAHRIAR QUAYYUM | progress |
| 09/22/2026 | Air barrier — testing | SHAHRIAR QUAYYUM | energy_progress |
| 09/22/2026 | Air barrier - visual inspection | SHAHRIAR QUAYYUM | energy_progress |
| 09/22/2026 | Insulation placement and R values | SHAHRIAR QUAYYUM | energy_progress |
| 09/22/2026 | Permanent certificate | SHAHRIAR QUAYYUM | energy_progress |
| 09/22/2026 | Fenestration areas | SHAHRIAR QUAYYUM | energy_progress |
| 09/22/2026 | Electric vehicle service equipment requirements | SHAHRIAR QUAYYUM | energy_progress |
| 09/22/2026 | Fenestration and door U-factor and product ratings | SHAHRIAR QUAYYUM | energy_progress |
| 09/22/2026 | Maintenance information | SHAHRIAR QUAYYUM | energy_progress |
| 09/22/2026 | Metering | SHAHRIAR QUAYYUM | energy_progress |
| 09/22/2026 | Fenestration air leakage | SHAHRIAR QUAYYUM | energy_progress |
| 09/22/2026 | Interior lighting power | SHAHRIAR QUAYYUM | energy_progress |
| 09/22/2026 | Structural Wood Frame | SHAHRIAR QUAYYUM | progress |
| 09/22/2026 | Footing and Foundation | SHAHRIAR QUAYYUM | progress |
| 09/22/2026 | Fire-Resistance Rated Construction | SHAHRIAR QUAYYUM | progress |
| 04/13/2026 | Structural Stability – Alterations of existing buildings | Malathi Ananthakrishnan | special |