| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 10/11/2023 | $4.2M | — | — → — | $2,705/sf building |
| 01/29/2015 | $1.9M | — | Private party → Private party | $1,178/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| BOHN ARCHITECTURE AND DESIGN | 7 | 02/12/2026 |
| LEVIN ENGINEERING PLLC | 4 | 09/09/2025 |
| ADVANCED ENGINEERING & INSPECT. PLL | 2 | 04/22/2025 |
| SAEED SYED | 4 | 02/19/2025 |
| CORNERSTONE DESIGNS | 1 | 10/08/2021 |
| Representative | Filings | Most Recent |
|---|---|---|
| 4444 PPPP CORP | 30 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| M.N.C. GENERAL CONTR CORP | General Contractor | 12 | 07/08/2026 |
| NESS MECHANICAL P & H INC | Plumbing | 2 | 06/28/2026 |
| SAFETY FIRE SPRINKLER CORP | Fire Protection | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| CITY-WIDE TESTING INC | 416 | 14 | 02/12/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Permit Issued | M.N.C. GENERAL CONTR CORP | 07/06/2026 |
| DOB NOW | Plumbing | Permit Issued | NESS MECHANICAL P & H INC | 06/23/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | M.N.C. GENERAL CONTR CORP | 06/22/2026 |
| DOB NOW | Structural | Signed-off | MNC GENERAL CONTR CORP | 02/23/2026 |
| DOB NOW | Construction Fence | Permit Issued | MNC GENERAL CONTR CORP | 12/24/2025 |
| DOB NOW | General Construction | Permit Issued | MNC GENERAL CONTR CORP | 12/24/2025 |
| DOB NOW | Sprinklers | Permit Issued | SAFETY FIRE SPRINKLER CORP | 10/31/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | MNC GENERAL CONTR CORP | 07/10/2025 |
| DOB NOW | Plumbing | Permit Issued | NESS MECHANICAL P & H INC | 05/27/2025 |
| DOB NOW | Structural | Signed-off | MNC GENERAL CONTR CORP | 01/03/2025 |
| DOB NOW | Foundation | Signed-off | MNC GENERAL CONTR CORP | 01/03/2025 |
| DOB NOW | Support of Excavation | Signed-off | MNC GENERAL CONTR CORP | 12/31/2024 |
| DOB NOW | Construction Fence | Permit Issued | MNC GENERAL CONTR CORP | 12/30/2024 |
| DOB NOW | General Construction | Permit Issued | MNC GENERAL CONTR CORP | 11/21/2024 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 02/12/2026 | Permit Issued | MNC GENERAL CONTR CORP | Heating and Air Conditioning Systems | Heat / Cool Daikin RXTA36AAVJU 3 tons · Vrf Outdoor ×4 RXTA60AAVJU 60,000 BTU · Vrf Outdoor ×4 RXTA48AAAVJU 4 tons · Heat Pump Outdoor ×2 RXTA48AAVJU 4 tons · Vrf Outdoor ×2 |
| 09/09/2025 | Permit Issued | MNC GENERAL CONTR CORP | Generators | Generators Cummins c60n6 60 kW · Generator ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/22/2025 | Permit Issued | SAFETY FIRE SPRINKLER COR | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/09/2025 | Permit Issued | NESS MECHANICAL P & H INC | Gas |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/27/2025 | Permit Issued | LENS ELECTRIC, INC | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/14/2024 | Permit Issued | MNC GENERAL CONTR CORP | Fence |
| 10/08/2021 | — | — | Fence |
| Date | Type | Result | Report |
|---|---|---|---|
| 05/07/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 04/27/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 08/01/2025 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 05/30/2025 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 05/30/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 03/24/2026 | Energy Code Compliance Inspections | ELIAS RASABI | progress |
| 03/24/2026 | Maintenance information | ELIAS RASABI | energy_progress |
| 03/24/2026 | Protection of exposed foundation insulation | ELIAS RASABI | energy_progress |
| 03/24/2026 | Fenestration and door U-factor and product ratings | ELIAS RASABI | energy_progress |
| 03/24/2026 | Fenestration areas | ELIAS RASABI | energy_progress |
| 03/24/2026 | Electric vehicle service equipment requirements | ELIAS RASABI | energy_progress |
| 03/24/2026 | Air barrier — testing | ELIAS RASABI | energy_progress |
| 03/24/2026 | Interior lighting power | ELIAS RASABI | energy_progress |
| 03/24/2026 | Permanent certificate | ELIAS RASABI | energy_progress |
| 03/24/2026 | Metering | ELIAS RASABI | energy_progress |
| 03/24/2026 | Insulation placement and R values | ELIAS RASABI | energy_progress |
| 03/24/2026 | Fenestration air leakage | ELIAS RASABI | energy_progress |
| 03/24/2026 | Air barrier - visual inspection | ELIAS RASABI | energy_progress |
| 03/24/2026 | Fire-Resistant Penetrations and Joints | ELIAS RASABI | special |
| 03/24/2026 | Post-installed Anchors | ELIAS RASABI | special |
| 03/24/2026 | Masonry | ELIAS RASABI | special |
| 03/24/2026 | Structural Stability – Alterations of existing buildings | ELIAS RASABI | special |
| 03/24/2026 | Exterior Insulation and Finish Systems (EIFS) | ELIAS RASABI | special |
| 03/24/2026 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | ELIAS RASABI | special |
| 03/24/2026 | Fire-Resistance Rated Construction | ELIAS RASABI | progress |
| 03/24/2026 | Preliminary | ELIAS RASABI | progress |
| 02/05/2026 | Fire-Resistant Penetrations and Joints | ELIAS RASABI | special |
| 02/05/2026 | HVAC-R and service water heating equipment | ELIAS RASABI | energy_progress |
| 02/05/2026 | Energy Code Compliance Inspections | ELIAS RASABI | progress |
| 02/05/2026 | Maintenance information | ELIAS RASABI | energy_progress |