1951Year Built
2Stories
C6Building Class
R3-2Zoning
489,600 sfGross Floor Area
350Units
LL97 CoveredRent Stabilized22 Open Violations ▸FDNY Report ↗
Walk-up cooperative · Owner of record: UNITED VETERAN MUTUAL HOUSING COMPANY INCORPORATED · 694,000 sf lot · 0.71 FAR built · Flood zone X
Locations of Work
Architecture
Floor 21p · 1 filing · 4 docs
Floor 1
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
EDWARD C. HICKS RA105/13/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KATARIA BUILDERS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KIT RENOVATION CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AFM INSPECTIONS & ENGINEE4675105/13/2021
Building Lifecycle
All (6)Filed (1)Permit Issued (1)Signed Off (1)Inspection (1)Objection (2)
12/21/2021
Signed off — Alteration
FILING HEREWITH PLANS AND APPLICATION FOR RENOVATIONS TO EXISTING KITCHEN ON SECOND FLOOR. PROVIDE NEW HEADER FOR OPENING KITCHEN AND LIVING ROOM. ALL AS PER PLANS FILED. PLUMBING TO BE FILED UNDER SEPARATE "LAA"
Q00521314-I1
12/16/2021
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
06/29/2021
Permit issued — General Construction
Q00521314-I1-GC
05/19/2021
Objection raised — Scope
05/19/2021
Objection resolved — Addressed
05/13/2021
Filed — Alteration
FILING HEREWITH PLANS AND APPLICATION FOR RENOVATIONS TO EXISTING KITCHEN ON SECOND FLOOR. PROVIDE NEW HEADER FOR OPENING KITCHEN AND LIVING ROOM. ALL AS PER PLANS FILED. PLUMBING TO BE FILED UNDER SEPARATE "LAA"
Q00521314-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offKIT RENOVATION CORP06/29/2021
3 projects · most recent 07/05/2021
General Wiring
FiledStatusContractorScope
07/05/2021CompleteR & T ELECTRICAL CORPGeneral Wiring
04/20/2018Permit IssuedLEADER ELECTRIC CO., INCGeneral Wiring
03/26/2018Permit IssuedJOSEPH WEINSTEIN ELECTRICGeneral Wiring
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
12/16/2021Pass-Final General Construction Non-Directive 14PassView ↗
▾Documents — 4 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/27/2026Q00521314-I1Request digital key ↗
▸Seals & Professional Certifications1
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/27/2026Q00521314-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/27/2026Q00521314-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00521314-I1Open ↗