← Back
Zoned residential, not Manhattan
2211 HUNTER AVENUE
BRONX · Co-op City · BIN 2130766
💬 Discuss this project
0Year Built
—Stories
V0Building Class
R3AZoning
0 sfGross Floor Area
0Units
Zoned residential, not Manhattan · Owner of record: GO HUNTER LLC · 4,750 sf lot · 0 FAR built · Flood zone X500
Locations of Work
ArchitectureStructural
Cellar4p · 1 filing · 12 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/13/2025$100K—— → —— not available
04/27/2015$130K—Private party → BILT 5, LLC— not available
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TSL ARCHITECT,P.C.107/21/2026
GERALD CALIENDO ARCHITECTS106/24/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
GERALD J. CALIENDO R.A., P.C.203/21/2026
Building Lifecycle
All (45)Filed (2)Objection (15)Special Inspection (28)
07/21/2026
Filed — New Building
Application is for a new 2 Family dwelling
X01402334-I1
12/08/2022
Special inspection requirement — Metering
12/08/2022
Special inspection requirement — Air barrier — testing
12/08/2022
Special inspection requirement — Protection of exposed foundation insulation
12/08/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
12/08/2022
Special inspection requirement — Duct leakage testing, insulation and design
12/08/2022
Special inspection requirement — Electric vehicle service equipment requirements
12/08/2022
Special inspection requirement — Ventilation and air distribution system
10/25/2022
Objection raised — Zoning
10/25/2022
Objection resolved — Resolved
10/25/2022
Objection raised — Zoning
10/25/2022
Objection resolved — Resolved
10/25/2022
Objection raised — Zoning
10/25/2022
Objection resolved — Resolved
10/25/2022
Objection raised — Fire_Protection
10/25/2022
Objection resolved — Resolved
10/25/2022
Objection raised — Fire_Protection
10/25/2022
Objection resolved — Resolved
10/25/2022
Objection raised — Energy
10/25/2022
Objection resolved — Resolved
10/25/2022
Objection raised — Scope
10/25/2022
Objection resolved — Resolved
06/29/2022
Objection raised — Zoning
06/24/2022
Filed — New Building
Herewith filing SOE plans of 2-Story New Building subsequent to X00760123-I1. The SOE design involves 1:1 excavation on exposure1,3&4 and installation of soldier beam system on exposure-2.
X00760123-I1
06/21/2022
Special inspection requirement — Masonry
06/17/2022
Special inspection requirement — Fire-Resistance Rated Construction
06/17/2022
Special inspection requirement — Final
06/17/2022
Special inspection requirement — HVAC-R and service water heating equipment
06/17/2022
Special inspection requirement — Maintenance information
06/17/2022
Special inspection requirement — Air barrier - visual inspection
06/17/2022
Special inspection requirement — HVAC-R and service water heating system controls
06/17/2022
Special inspection requirement — Permanent certificate
06/17/2022
Special inspection requirement — Fenestration air leakage
06/17/2022
Special inspection requirement — Insulation placement and R values
06/17/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
06/17/2022
Special inspection requirement — Interior lighting power
06/17/2022
Special inspection requirement — Concrete - Cast-In-Place
06/17/2022
Special inspection requirement — Fenestration areas
06/17/2022
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
06/17/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/17/2022
Special inspection requirement — Heating Systems
06/17/2022
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
06/17/2022
Special inspection requirement — Subgrade Inspections
06/17/2022
Special inspection requirement — Mechanical Systems
06/17/2022
Special inspection requirement — Energy Code Compliance Inspections
Nothing on file for this building.
1 project · most recent 06/24/2022
Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
06/24/2022——Heating Systems
Heating
Williamson GWA-070-N-T 58,000 BTU · Boiler ×2
1 project · most recent 06/24/2022
Gas Storm Water/Sanitary
FiledStatusContractorScope
06/24/2022——Gas, Storm, Water/Sanitary
2 projects · most recent 07/21/2026
Steel Concrete Wood
FiledStatusContractorScope
07/21/2026——1 scope_items
06/24/2022——Steel, Concrete, Wood
▾Special Inspection Requirements (DOB NOW) — 28
DateRequirementInspectorRole
12/08/2022Metering—energy_progress
12/08/2022Air barrier — testing —energy_progress
12/08/2022Protection of exposed foundation insulation—energy_progress
12/08/2022HVAC-R and service water piping design and insulation—energy_progress
12/08/2022Duct leakage testing, insulation and design—energy_progress
12/08/2022Electric vehicle service equipment requirements—energy_progress
12/08/2022Ventilation and air distribution system—energy_progress
06/21/2022Masonry—special
06/17/2022Fire-Resistance Rated Construction—progress
06/17/2022Final—progress
06/17/2022HVAC-R and service water heating equipment—energy_progress
06/17/2022Maintenance information—energy_progress
06/17/2022Air barrier - visual inspection—energy_progress
06/17/2022HVAC-R and service water heating system controls—energy_progress
06/17/2022Permanent certificate—energy_progress
06/17/2022Fenestration air leakage—energy_progress
06/17/2022Insulation placement and R values—energy_progress
06/17/2022Fenestration and door U-factor and product ratings—energy_progress
06/17/2022Interior lighting power—energy_progress
06/17/2022Concrete - Cast-In-Place—special
06/17/2022Fenestration areas—energy_progress
06/17/2022Excavations - Sheeting, Shoring, and Bracing—special
06/17/2022Fire-Resistant Penetrations and Joints—special
06/17/2022Heating Systems—special
06/17/2022Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
Latest 25 of 28.
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/16/2026X01402334-S2Request digital key ↗
08/16/2026X01402334-S1Request digital key ↗
08/16/2026X01402334-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram1
08/16/2026X01402334-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/16/2026X01402334-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/16/2026X01402334-I1Open ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/16/2026X01402334-S2Open ↗
08/16/2026X01402334-S1Open ↗
08/16/2026X01402334-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/29/2026X01402334-S2Open ↗
08/29/2026X01402334-S2Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/29/2026X01402334-S2Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/16/2026X01402334-I1Open ↗
▸Other Documents3
▸DOB NOWProperty Ownership Certification1
08/16/2026X01402334-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/16/2026X01402334-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/16/2026X01402334-I1Open ↗