← Back
BuildNYC
One family attached or semi-detached
2215 HOMECREST AVENUE
BROOKLYN · BIN 3200657
💬 Discuss this project
1950Year Built
1Stories
A5Building Class
R4Zoning
2,927 sfGross Floor Area
1Units
0 Active ViolationsFDNY Report ↗
One family attached or semi-detached · 2,350 sf lot · 1.25 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralMechanicalFire ProtectionCivilGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof20p · 1 filing · 17 docs
Attic7p · 1 filing · 11 docs
Floor 317p · 1 filing · 17 docs
Floor 224p · 2 filings · 20 docs
Floor 1MIZRAHI HOUSE TEMPORARY CONSTRUCTION FENCE29p · 4 filings · 20 docs
Cellar26p · 2 filings · 20 docs
Basement1p · 1 filing · 17 docs
Sub-Basement16p · 1 filing · 17 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Builders Inc Alnaya203/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Roccanova Engineering202/19/2025
Richard Wainer Architect306/01/2023
Solomon Rosenzweig P.E.404/03/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Boyd Consulting1403/21/2026
City Expediting403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Alnaya BuildersGeneral Contractor807/08/2026
Alnaya BuildersScaffold707/08/2026
Jodom MechanicalPlumbing403/22/2026
Safety Fire Sprinklerspecialty_contractor407/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Solomon Rosenzweig P.E. P1801602/19/2025
Building Lifecycle
12/05/2025
Signed off — Alteration
FILING FOR STRUCTURAL WORK IN CONJUNCTION WITH ONE (1) FAMILY HOUSE; RENOVATION, HORIZONTAL & VERTICAL ENLARGEMENT ADDING 2ND + 3RD FLOORS AND CHANGING BASEMENT TO CELLAR FILED UNDER APPLICATION JOB # 320912900.
B00349697-S1
12/05/2025
Signed off — Alteration
FILING FOR STRUCTURAL WORK IN CONJUNCTION WITH ONE (1) FAMILY HOUSE; RENOVATION, HORIZONTAL & VERTICAL ENLARGEMENT ADDING 2ND + 3RD FLOORS AND CHANGING BASEMENT TO CELLAR FILED UNDER APPLICATION JOB # 320912900.
B00349697-I1
07/28/2025
Signed off — Alteration
B00344296-I1
07/24/2025
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
06/24/2025
Signed off — Alteration
New Sprinkler System in conjunction with Alt1 Job #320912900
B00396520-I1
64 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offSafety Fire Sprinkler10/31/2024
DOB NOWCurb CutSigned-offAlnaya Builders08/21/2024
DOB NOWConstruction FenceSigned-offAlnaya Builders08/09/2024
DOB NOWSprinklersSigned-offSafety Fire Sprinkler06/23/2023
DOB NOWConstruction FenceSigned-offAlnaya Builders05/25/2023
DOB NOWStructuralSigned-offAlnaya Builders11/10/2022
DOB NOWFoundationSigned-offAlnaya Builders11/10/2022
DOB NOWConstruction FenceSigned-offAlnaya Builders06/21/2022
DOB NOWFoundationSigned-offAlnaya Builders12/22/2021
DOB NOWStructuralSigned-offAlnaya Builders12/09/2021
DOB NOWConstruction FenceSigned-offAlnaya Builders06/15/2021
DOB NOWConstruction FenceSigned-offAlnaya Builders01/12/2021
BIS—ISSUEDAlnaya Builders06/28/2024
BISPLISSUEDJodom Mechanical06/13/2024
BIS—ISSUEDAlnaya Builders06/10/2024
BIS—ISSUEDAlnaya Builders06/02/2023
BIS—ISSUEDAlnaya Builders05/25/2023
BISPLISSUEDJodom Mechanical03/09/2023
BIS—ISSUEDAlnaya Builders05/26/2022
BIS—RE-ISSUEDAlnaya Builders07/16/2021
BIS—RE-ISSUEDAlnaya Builders07/16/2021
BIS—ISSUEDAlnaya Builders03/10/2021
1 project · most recent 11/10/2025
General Wiring
FiledStatusContractorScope
11/10/2025CompleteLens ElectricGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
07/24/2025Pass-Final Curb Cut Non-Directive 14PassView ↗
03/20/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
10/30/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
02/25/2025Fire-Resistant Penetrations and JointsSolomon Rosenzweigspecial
02/25/2025Sprinkler SystemsSolomon Rosenzweigspecial
02/18/2025Sprinkler SystemsSolomon Rosenzweigspecial
02/18/2025Fire-Resistant Penetrations and JointsSolomon Rosenzweigspecial
04/05/2023Structural Stability – Alterations of existing buildingsSolomon Rosenzweigspecial
04/05/2023Subgrade InspectionsSolomon Rosenzweigspecial
04/05/2023Concrete - Cast-In-PlaceSolomon Rosenzweigspecial
04/05/2023FinalPRAMODRAY SHAHprogress
04/05/2023Footing and FoundationSolomon Rosenzweigprogress
03/28/2023Structural Stability – Alterations of existing buildingsSolomon Rosenzweigspecial
03/28/2023Footing and FoundationSolomon Rosenzweigprogress
03/28/2023FinalSolomon Rosenzweigprogress
03/28/2023Concrete - Cast-In-PlaceSolomon Rosenzweigspecial
03/28/2023Subgrade InspectionsSolomon Rosenzweigspecial
189 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account