| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 12/03/2025 | Permit Issued | B36 SERVICES INC | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Lg arum121BTe5 10 tons · Vrf Outdoor ×2 arum144BTe5 12 tons · Vrf Outdoor ×2 arum168BTe5 14 tons · Vrf Outdoor ×2 Ventilation Captiveaire CAS-HVAC3-E.602-24-15T-ERV 3,800 CFM · Doas ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/03/2025 | — | — | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/03/2025 | — | — | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/31/2026 | Permit Issued | ELECTRICIAN NYC LLC | General Wiring |
| 07/17/2026 | Permit Issued | FAMULARO ELEC'L CONTR'G C | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/03/2025 | Permit Issued | B36 SERVICES INC | Steel, Masonry, Wood |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 10/27/2025 | $5.0M | — | — → — | $310/sf building |
| 09/30/2024 | $5.5M | — | CONGREGATION BETH BRACHA AND YACKOB INC → 2221 AVE R HOLDINGS LLC | $341/sf building |
| 03/06/2018 | $3.8M | — | Private party → CONGREGATION BETH BRACHA AND YACKOB, INC. | $232/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| TSF ENGINEERING, PC | 3 | 12/03/2025 |
| M C STRUCTURAL ENGINEERING | 4 | 12/02/2025 |
| EDIFICE DRAFTING AND SERVICES | 2 | 12/02/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| 4444 PPPP CORP | 18 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| M.N.C. GENERAL CONTR CORP | General Contractor | 2 | 04/09/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| CITY-WIDE TESTING INC | 416 | 9 | 12/03/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | B36 SERVICES INC | 09/03/2026 |
| DOB NOW | General Construction | Permit Issued | MNC GENERAL CONTR CORP | 12/22/2025 |
| DOB NOW | Foundation | Permit Issued | MNC GENERAL CONTR CORP | 12/08/2025 |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 12/19/2025 | Fire-Resistant Penetrations and Joints | ELIAS RASABI | special |
| 12/19/2025 | Air barrier continuity plan testing | ELIAS RASABI | energy_progress |
| 12/19/2025 | Fenestration air leakage | ELIAS RASABI | energy_progress |
| 12/19/2025 | Fenestration areas | ELIAS RASABI | energy_progress |
| 12/19/2025 | Exterior lighting power | ELIAS RASABI | energy_progress |
| 12/19/2025 | Interior lighting power | ELIAS RASABI | energy_progress |
| 12/19/2025 | Structural Stability – Alterations of existing buildings | ELIAS RASABI | special |
| 12/19/2025 | Exterior Insulation and Finish Systems (EIFS) | ELIAS RASABI | special |
| 12/19/2025 | Energy Code Compliance Inspections | ELIAS RASABI | progress |
| 12/19/2025 | Fire-Resistance Rated Construction | ELIAS RASABI | progress |
| 12/19/2025 | Lighting controls | ELIAS RASABI | energy_progress |
| 12/19/2025 | Insulation placement and R values | ELIAS RASABI | energy_progress |
| 12/19/2025 | Fenestration and door U-factor and product ratings | ELIAS RASABI | energy_progress |
| 12/19/2025 | Maintenance information | ELIAS RASABI | energy_progress |
| 12/19/2025 | Air barrier - visual inspection | ELIAS RASABI | energy_progress |
| 12/19/2025 | Air barrier — testing | ELIAS RASABI | energy_progress |
| 12/19/2025 | Metering | ELIAS RASABI | energy_progress |
| 12/19/2025 | Protection of exposed foundation insulation | ELIAS RASABI | energy_progress |
| 12/19/2025 | Masonry | ELIAS RASABI | special |
| 12/19/2025 | Structural Steel - High Strength Bolting | ELIAS RASABI | special |
| 12/19/2025 | Structural Steel - Welding | ELIAS RASABI | special |
| 12/19/2025 | Structural Steel - Details | ELIAS RASABI | special |
| 12/19/2025 | Structural Cold-Formed Steel | ELIAS RASABI | special |
| 12/19/2025 | Post-installed Anchors | ELIAS RASABI | special |
| 12/19/2025 | Final | ELIAS RASABI | progress |