| Owner | Filings | Most Recent |
|---|---|---|
| Fairmont Realty Group | 2 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 06/11/2026 | $1.4M | — | FAIRMONT REALTY GROUP LLC → Private party | $555/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| Pirooz Engineering | 7 | 01/15/2026 |
| Representative | Filings | Most Recent |
|---|---|---|
| Royal Expediting | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| A & S Contractors of NY I | General Contractor | 3 | 04/09/2026 |
| A & S Contractors of NY I | Scaffold | 2 | 07/08/2026 |
| Superior Plumbing & Heating | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| Pirooz Engineering | 7177 | 5 | 01/15/2026 |
| IP Concrete Testing and I | 6252 | 2 | 10/02/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Construction Fence | Signed-off | A S Contractors of NY I | 05/08/2025 |
| DOB NOW | Plumbing | Signed-off | Superior Plumbing & Heating | 03/13/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | A S Contractors of NY I | 06/20/2024 |
| DOB NOW | Curb Cut | Signed-off | A S Contractors of NY I | 06/14/2024 |
| DOB NOW | Construction Fence | Signed-off | A S Contractors of NY I | 05/09/2024 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 01/15/2026 | Permit Issued | A & S Contractors of NY I | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric Condenser: MXZ-SM48NAMHZ
Air handler: MSZ-GS09(3)
Air handler: MSZ-GS12 48,000 BTU · Heat Pump Outdoor ×6 Condenser - MUZ-FX12NLHZ Air handler - MSZ-FX12NL 23,500 BTU · Heat Pump Outdoor ×3 Ventilation Renewaire SL70H 72 CFM · Erv ×6 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/11/2026 | Complete | Cole Electric | — |
| 01/28/2025 | Complete | Power Surge Electric | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 01/15/2026 | Permit Issued | A & S Contractors of NY I | Concrete, Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 01/15/2026 | Permit Issued | A & S Contractors of NY I | Earthwork |
| Date | Type | Result | Report |
|---|---|---|---|
| 05/27/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 12/04/2025 | Pass-Final Curb Cut Non-Directive 14 | Pass | View ↗ |
| 11/07/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 09/09/2025 | Certified Sprinkler (PL)-SP-Fixtures (PL)-Finish | Certified | View ↗ |
| 03/21/2025 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 03/21/2025 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 03/21/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 03/21/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 04/24/2026 | Electric vehicle service equipment requirements | PIROOZ SOLTANIZADEH | energy_progress |
| 04/24/2026 | Fenestration and door U-factor and product ratings | PIROOZ SOLTANIZADEH | energy_progress |
| 04/24/2026 | HVAC-R and service water heating system controls | PIROOZ SOLTANIZADEH | energy_progress |
| 04/24/2026 | Duct leakage testing, insulation and design | PIROOZ SOLTANIZADEH | energy_progress |
| 04/24/2026 | HVAC-R and service water heating equipment | PIROOZ SOLTANIZADEH | energy_progress |
| 04/24/2026 | Metering | PIROOZ SOLTANIZADEH | energy_progress |
| 04/24/2026 | Fenestration areas | PIROOZ SOLTANIZADEH | energy_progress |
| 04/24/2026 | Maintenance information | PIROOZ SOLTANIZADEH | energy_progress |
| 04/24/2026 | Ventilation and air distribution system | PIROOZ SOLTANIZADEH | energy_progress |
| 04/24/2026 | Excavations - Sheeting, Shoring, and Bracing | PIROOZ SOLTANIZADEH | special |
| 04/24/2026 | Masonry | PIROOZ SOLTANIZADEH | special |
| 04/24/2026 | Heating Systems | PIROOZ SOLTANIZADEH | special |
| 04/24/2026 | Subsurface Investigations (Borings/Test Pits) | INDARDEO PARBHUNATH | special |
| 04/24/2026 | Fire-Resistant Penetrations and Joints | PIROOZ SOLTANIZADEH | special |
| 04/24/2026 | Subgrade Inspections | PIROOZ SOLTANIZADEH | special |
| 04/24/2026 | Mechanical Systems | PIROOZ SOLTANIZADEH | special |
| 04/24/2026 | Concrete - Cast-In-Place | PIROOZ SOLTANIZADEH | special |
| 04/24/2026 | Energy Code Compliance Inspections | PIROOZ SOLTANIZADEH | progress |
| 04/24/2026 | Final | NAVEEN KUMAR | progress |
| 04/24/2026 | Fire-Resistance Rated Construction | PIROOZ SOLTANIZADEH | progress |
| 04/24/2026 | Structural Wood Frame | PIROOZ SOLTANIZADEH | progress |
| 04/24/2026 | Footing and Foundation | PIROOZ SOLTANIZADEH | progress |
| 04/24/2026 | Preliminary | PIROOZ SOLTANIZADEH | progress |
| 04/24/2026 | Interior lighting power | PIROOZ SOLTANIZADEH | energy_progress |
| 04/24/2026 | HVAC-R and service water piping design and insulation | PIROOZ SOLTANIZADEH | energy_progress |