← Back
One story retail building
223 AVENUE A
MANHATTAN · BIN 1006019
💬 Discuss this project
1951Year Built
1Stories
K1Building Class
C1-6AZoning
4,561 sfGross Floor Area
6Units
4 Open Violations ▸
One story retail building · Owner of record: PATTWIN EAST REALTY CORP · 4,564 sf lot · 1 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingCivil
Roof7p · 1 filing · 7 docs
Floor 120p · 5 filings · 20 docs
Cellar31p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
W L YEE COMPANY1907/08/2026
PATIWIN EAST REALT CORP/K103/22/2026
PATTWIN EAST REALTY1403/22/2026
BLACKSTONE DEVELOPERS103/21/2026
COMPASS ROCK REAL ESTATE103/21/2026
CPNY203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TALAL ALOKUSH PE108/21/2025
BITOPI CONSULTANTS LLC110/31/2023
ZELTA DESIGN507/31/2023
ALPHA HOME DESIGN LLC203/30/2023
BILLAH ENGINEERING PLLC207/16/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
INDESIGN STUDIO403/21/2026
SUPERIOR FIRE CONTROL103/21/2026
EPAC BUILDING CONSULTING INC1003/21/2026
INSHA BUILDING CONSULTANTS403/21/2026
ABT VENTURES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ALL AMERICAN CONSTRUCTIONGeneral Contractor307/08/2026
NEPTUNE SIGNS AWNINGSScaffold207/08/2026
HESCOTT, CARDINALElectrical103/21/2026
HOWARD ZAMKOFFElectrical103/21/2026
IRON WORKERS LOCAL 40Electrical103/21/2026
QUINTANA, DAVIDElectrical103/21/2026
RAMSARRAN, RAMESHElectrical103/21/2026
SANG CHEUNGElectrical103/21/2026
ASPESI, MARCELOElectrical103/21/2026
VINCENT LOMBARDOZZIElectrical103/21/2026
A & A REMODELING INCGeneral Contractor104/08/2026
SUPERIOR FIRE CONTROL INCGeneral Contractor104/09/2026
CROSSFIELD PLBG.&HTGPlumbing107/08/2026
VILLAGE P & H NY INCPlumbing107/08/2026
UNITED ELEC'L CONT'G CORPElectrical103/22/2026
CHETRAM, RISHIRAMElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BITOPI CONSULTANTS LLC7036110/31/2023
ZELTA INSPECT LLC7764107/22/2022
BILLAH ENGINEERING5838207/16/2021
Building Lifecycle
All (66)Filed (11)Permit Issued (8)Signed Off (5)Violation (21)Inspection (3)Special Inspection (18)
03/30/2026
Signed off — Alteration
INSTALL GROCERY KITCHEN HOOD AND DUCTWORK AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00949210-I1
11/12/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/03/2025
Signed off — Alteration
M01275076-I1
09/24/2025
Permit issued — General Construction
M01275076-I1-GC
08/21/2025
Filed — Alteration
M01275076-I1
02/24/2025
Signed off — Alteration
PROPOSED TEMPORARY CONSTRUCTION FENCE. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
M00779611-I1
09/13/2024
Signed off — Alteration
ERECT AN ILLUMINATED SIGN ON WALL.NOT WITHIN VIEW OF ARTERIAL HIGHWAY OR PUBLIC PARK 1/2 ACRE OR MORE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00846839-I1
09/13/2024
Signed off — Alteration
M00846342-I1
11/02/2023
Permit issued — Mechanical Systems
M00949210-I1-MS
10/31/2023
Filed — Alteration
INSTALL GROCERY KITCHEN HOOD AND DUCTWORK AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00949210-I1
07/31/2023
Filed — Alteration
PLUMBING FILING
M00776092-P2
07/13/2023
Filed — Alteration
PLUMBING FILING
M00776092-P1
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/09/2023
Permit issued — Sign
M00846342-I1-SG
06/08/2023
Permit issued — Sign
M00846839-I1-SG
03/30/2023
Filed — Alteration
ERECT AN ILLUMINATED SIGN ON WALL.NOT WITHIN VIEW OF ARTERIAL HIGHWAY OR PUBLIC PARK 1/2 ACRE OR MORE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00846839-I1
03/30/2023
Filed — Alteration
M00846342-I1
03/23/2023
Special inspection requirement — Final
YAN GAO
10/14/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/14/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/14/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
10/07/2022
Permit issued — Plumbing
M00776092-I1-PL
08/30/2022
Permit issued — Mechanical Systems
M00776091-I1-GC-CX
08/16/2022
Permit issued — Construction Fence
M00779611-I1-FN
07/22/2022
Filed — Alteration
PROPOSED TEMPORARY CONSTRUCTION FENCE. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
M00779611-I1
07/22/2022
Filed — Alteration
PLUMBING FILING
M00776092-I1
07/22/2022
Filed — Alteration
M00776091-I1
07/15/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
ERIK LIEPINS
07/15/2022
Special inspection requirement — Mechanical Systems
ERIK LIEPINS
07/15/2022
Special inspection requirement — Energy Code Compliance Inspections
ERIK LIEPINS
07/15/2022
Special inspection requirement — Final
ERIK LIEPINS
07/15/2022
Special inspection requirement — Lighting controls
ERIK LIEPINS
07/15/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
ERIK LIEPINS
07/15/2022
Special inspection requirement — HVAC-R and service water heating system controls
ERIK LIEPINS
07/15/2022
Special inspection requirement — Maintenance information
ERIK LIEPINS
07/15/2022
Special inspection requirement — Fenestration areas
ERIK LIEPINS
07/15/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
ERIK LIEPINS
07/15/2022
Special inspection requirement — Duct leakage testing, insulation and design
ERIK LIEPINS
07/15/2022
Special inspection requirement — Shutoff dampers
ERIK LIEPINS
07/15/2022
Special inspection requirement — HVAC-R and service water heating equipment
ERIK LIEPINS
07/15/2022
Special inspection requirement — Interior lighting power
ERIK LIEPINS
07/15/2022
Special inspection requirement — Exterior lighting power
ERIK LIEPINS
07/15/2022
Special inspection requirement — Fenestration air leakage
ERIK LIEPINS
07/16/2021
Filed — Alteration
Filing in related to alt2 application # 140985414. plumbing work type to install commercial cooking equipment, and new plumbing fixtures inside 1st fl corner commercial space (DELI)
M00451988-P1
07/16/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
MOHAMMAD BILLAH
03/22/2021
Violation issued (ECB, closed)
Construction
03/01/2021
Permit issued — Plumbing
M00451988-I1-PL
01/21/2021
Violation issued (ECB, closed)
Construction
01/21/2021
Violation issued (ECB, closed)
Construction
01/11/2021
Filed — Alteration
Filing in related to alt2 application # 140985414. plumbing work type to install commercial cooking equipment, and new plumbing fixtures inside 1st fl corner commercial space (DELI)
M00451988-I1
03/16/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/11/2019
Violation issued (ECB, closed)
Construction
04/17/2013
Violation issued (ECB, closed)
Signs
01/09/2013
Violation issued (ECB, closed)
Signs
01/09/2013
Violation issued (ECB, closed)
Signs
01/09/2013
Violation issued (ECB, closed)
Signs
01/09/2013
Violation issued (ECB, closed)
Signs
Latest 60 of 66 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offA A REMODELING09/24/2025
DOB NOWMechanical SystemsSigned-offSUPERIOR FIRE CONTROL INC11/02/2023
DOB NOWSignSigned-offNEPTUNE SIGNS&AWNINGS INC06/09/2023
DOB NOWSignSigned-offNEPTUNE SIGNS&AWNINGS INC06/08/2023
DOB NOWPlumbingPermit IssuedVILLAGE P & H NY INC10/07/2022
DOB NOWMechanical SystemsPermit IssuedALL AMERICAN CONSTRUCTION08/30/2022
DOB NOWConstruction FenceSigned-offALL AMERICAN CONSTRUCTION08/16/2022
DOB NOWPlumbingSigned-offCROSSFIELD PLBG.&HTG03/01/2021
BISOTISSUEDRDT HOME INPROVEMENT CORP12/10/2020
BIS—ISSUEDTRU-ART SIGN CO. INC07/08/2015
BISPLISSUEDPLUMBING & HTG DOCTOR INC03/31/2015
BISMHISSUEDHASSAN CHANNAOUI03/26/2015
BISOTISSUEDHASSAN CHANNAOUI03/25/2015
BIS—ISSUEDULTIMATE SIGNS&DESIGNS CO01/30/2013
BIS—ISSUEDULTIMATE SIGNS&DESIGNS CO01/09/2013
BIS—ISSUEDULTIMATE SIGNS&DESIGNS CO12/24/2012
BIS—ISSUEDMETROPOLITAN SIGN&RIG COR11/08/2012
BIS—ISSUEDMETROPOLITAN SIGN&RIG COR10/26/2012
BIS—ISSUEDMETROPOLITAN SIGN&RIG COR10/09/2012
BIS—ISSUEDMETROPOLITAN SIGN&RIG COR10/03/2012
BIS—ISSUEDMETROPOLITAN SIGN&RIG COR09/06/2012
BIS—ISSUEDMETROPOLITAN SIGN&RIG COR08/24/2012
BIS—ISSUEDMETROPOLITAN SIGN&RIG COR07/20/2012
BIS—ISSUEDMETROPOLITAN SIGN&RIG COR07/17/2012
BIS—ISSUEDMETROPOLITAN SIGN&RIG COR11/10/2011
BISOTISSUEDMETROPOLITAN SIGN & RIGGI11/10/2011
BISFPISSUEDFIRE COMMAND CO INC06/08/2006
BISOTISSUEDARC ELECTRICAL & MECH CON04/11/2006
BISFBISSUEDSTEPHEN BRAUN10/12/2005
BIS—ISSUEDNY SIGN CITY INC.02/28/2005
BISOTISSUEDNEW YORK SIGN CITY INC12/21/2004
BISOTISSUEDFORDHAM REFRI & AIR-COND07/26/1999
BISOTISSUEDNOVA PLMB & HTNG INCP10/07/1998
BISFPISSUEDACTIVE FIRE EXTI INC04/28/1994
2 projects · most recent 07/31/2023
Gas Water/Sanitary
FiledStatusContractorScope
07/31/2023Permit IssuedVILLAGE P & H NY INCGas, Water/Sanitary
07/16/2021Signed-offCROSSFIELD P & H CORPGas, Water/Sanitary
5 projects · most recent 03/01/2023
General Wiring
FiledStatusContractorScope
03/01/2023Permit IssuedUNITED ELEC'L CONT'G CORP4 meters, 4 new_meters
03/18/2021Permit IssuedPOWER SURGE ELECTRIC, INCGeneral Wiring
02/11/2021Permit IssuedPOWER SURGE ELECTRIC, INCGeneral Wiring
01/28/2021Permit IssuedPOWER SURGE ELECTRIC, INCGeneral Wiring
01/27/2021Permit IssuedPOWER SURGE ELECTRIC, INCGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
10/14/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/14/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/14/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
03/23/2023FinalYAN GAOprogress
07/15/2022Fire-Resistant Penetrations and JointsERIK LIEPINSspecial
07/15/2022Mechanical SystemsERIK LIEPINSspecial
07/15/2022Energy Code Compliance InspectionsERIK LIEPINSprogress
07/15/2022FinalERIK LIEPINSprogress
07/15/2022Lighting controlsERIK LIEPINSenergy_progress
07/15/2022Fenestration and door U-factor and product ratingsERIK LIEPINSenergy_progress
07/15/2022HVAC-R and service water heating system controlsERIK LIEPINSenergy_progress
07/15/2022Maintenance informationERIK LIEPINSenergy_progress
07/15/2022Fenestration areasERIK LIEPINSenergy_progress
07/15/2022HVAC-R and service water piping design and insulationERIK LIEPINSenergy_progress
07/15/2022Duct leakage testing, insulation and designERIK LIEPINSenergy_progress
07/15/2022Shutoff dampersERIK LIEPINSenergy_progress
07/15/2022HVAC-R and service water heating equipmentERIK LIEPINSenergy_progress
07/15/2022Interior lighting powerERIK LIEPINSenergy_progress
07/15/2022Exterior lighting powerERIK LIEPINSenergy_progress
07/15/2022Fenestration air leakageERIK LIEPINSenergy_progress
07/16/2021Fire-Resistant Penetrations and JointsMOHAMMAD BILLAHspecial
▾Documents — 244 on file (BIS + DOB NOW)
▸Plans & Drawings12
▸DOB NOWPlans/Sketch10
09/02/2026M00779611-I1Request digital key ↗
09/02/2026M00776091-I1Request digital key ↗
08/31/2026M00846839-I1Request digital key ↗
Showing 3 of 10 on file for this type
▸DOB NOWPlans/Sketch - Plumbing2
09/03/2026M00451988-I1Request digital key ↗
08/15/2026M00451988-P1Request digital key ↗
▸Applications & Permits34
▸BISPLAN / WORK APPROVAL APPLICATION17
12/09/2020140985414Open ↗
06/30/2015122436774Open ↗
06/10/2015122331814Open ↗
Showing 3 of 17 on file for this type
▸BISWORK PERMIT APPLICATION17
12/10/2020140985414Open ↗
07/16/2015122436774Open ↗
04/07/2015122331814Open ↗
Showing 3 of 17 on file for this type
▸Seals & Professional Certifications66
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION21
10/16/2015122436774Open ↗
06/30/2015122436774Open ↗
04/02/2013121476615Open ↗
Showing 3 of 21 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST13
06/30/2015122436774Open ↗
06/10/2015122331814Open ↗
01/31/2013121474920Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature12
09/02/2026M00779611-I1Open ↗
09/02/2026M00776091-I1Open ↗
08/31/2026M00846342-I1Open ↗
Showing 3 of 12 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM10
01/31/2013121474920Open ↗
12/26/2012121467769Open ↗
11/14/2012121425957Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026M00776091-I1Open ↗
09/01/2026M00776091-I1Open ↗
09/01/2026M00776091-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
12/09/2020140985414Open ↗
06/30/2015122436774Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026M00776091-I1Open ↗
08/25/2026M00451988-I1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
12/09/2020140985414Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
12/09/2020140985414Open ↗
▸Trade Schedules & Equipment10
▸BISEQUIPMENT USE PERMITS3
08/14/2020122331814Open ↗
08/14/2020122331814Open ↗
08/06/2020122331814Open ↗
▸BISSELF-CERT PLUMBING NOTICE3
01/06/2016122331814Open ↗
07/14/2015122331814Open ↗
06/04/2015122331814Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
06/10/2015122331814Open ↗
06/08/2015122331814Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT2
08/14/2020122331814Open ↗
08/06/2020122331814Open ↗
▸Environmental & Asbestos26
▸BISASBESTOS: CERTIFICATION (DEP ACP5)12
12/09/2020140985414Open ↗
06/30/2015122436774Open ↗
01/31/2013121474920Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
09/02/2026M00776091-I1Open ↗
08/29/2026M00776092-P1Open ↗
08/29/2026M00776092-P3Open ↗
Showing 3 of 9 on file for this type
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)3
01/10/2013121476615Open ↗
12/26/2012121467769Open ↗
08/27/2012121346882Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
11/12/2011120890312Open ↗
11/12/2011120890303Open ↗
▸Energy Compliance6
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
12/09/2020140985414Open ↗
08/06/2020122331814Open ↗
08/06/2020122331814Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
08/06/2020122331814Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
12/09/2020140985414Open ↗
▸BISFENESTRATION AREAS1
12/10/2020140985414Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY3
12/09/2020140985414Open ↗
08/06/2020122331814Open ↗
08/06/2020122331814Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
12/10/2020140985414Open ↗
▸Approvals, Objections & Sign-offs31
▸BISADMINISTRATIVE OBJECTIONS12
01/31/2013121474920Open ↗
01/10/2013121476615Open ↗
12/26/2012121467769Open ↗
Showing 3 of 12 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST9
08/06/2020122331814Open ↗
10/16/2015122436774Open ↗
04/02/2013121476615Open ↗
Showing 3 of 9 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION6
03/06/2013121392135Open ↗
01/08/2013121414291Open ↗
12/05/2012121361310Open ↗
Showing 3 of 6 on file for this type
▸BISLETTERS - APPROVED FABRICATION CERTIFICATIONS3
02/28/2013121392019Open ↗
02/28/2013121467769Open ↗
02/15/2013121141996Open ↗
▸BISFINAL1
12/10/2020140985414Open ↗
▸Cost, Insurance & Ownership22
▸BISCOST AFFIDAVIT22
12/09/2020140985414Open ↗
08/06/2020122331814Open ↗
10/16/2015122436774Open ↗
Showing 3 of 22 on file for this type
▸Filing & Intake Forms20
▸BISEFILING COVER SHEET13
06/30/2015122436774Open ↗
01/31/2013121474920Open ↗
01/11/2013121476615Open ↗
Showing 3 of 13 on file for this type
▸BISADDITIONAL INFORMATION6
03/05/2021140985414Open ↗
06/08/2015122331814Open ↗
06/26/2013120890303Open ↗
Showing 3 of 6 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
12/09/2020140985414Open ↗
▸Other Documents13
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION10
04/02/2013121476615Open ↗
01/11/2013121476615Open ↗
12/26/2012121467769Open ↗
Showing 3 of 10 on file for this type
▸BISSupporting Document: Fee Exempt2
07/19/2012121148258Open ↗
07/19/2012121148258Open ↗
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
08/06/2020122331814Open ↗