← Back
One family attached or semi-detached
223 REVERE AVENUE
BRONX · Throgs Neck-Schuylerville · BIN 2080986
💬 Discuss this project
1955Year Built
2Stories
A5Building Class
R4-1Zoning
1,764 sfGross Floor Area
1Units
One family attached or semi-detached · 1,800 sf lot · 0.98 FAR built · Flood zone X
Locations of Work
StructuralPlumbing
Floor 11p · 1 filing · 5 docs
Cellar1p · 1 filing · 5 docs
Basement1p · 1 filing · 5 docs
Filed — no permit issued1p · 1 filing · 3 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/03/2024$700K—— → —$397/sf building
07/28/2020$570K—— → —$323/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
STUDIO 51 ARCHITECTURE, PLLC207/24/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
B2 CODE CONSULTANTS403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BES MECHANICAL LLCPlumbing107/08/2026
N.Y. EMS MECHANICAL CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AP PROFESSIONAL ENGINEERI5974207/24/2021
Building Lifecycle
All (9)Filed (2)Permit Issued (2)Inspection (2)Special Inspection (3)
01/31/2023
Permit issued — Plumbing
X00551893-I1-PL
08/13/2021
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/06/2021
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
07/24/2021
Filed — Alteration
X00553818-I1
07/20/2021
Permit issued — Plumbing
X00551893-I1-PL
07/07/2021
Filed — Alteration
INSTALL NEW HWH & FURNACE IN BASEMENT AND DRYWE ON THE 1ST FLOOR. NO CHANGE IN USE, OCCUPANCY, OR MEANS OF EGRESS.
X00551893-I1
07/02/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
GURVINDER SINGH
07/02/2021
Special inspection requirement — Energy Code Compliance Inspections
GURVINDER SINGH
07/02/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
GURVINDER SINGH
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedL AND I MECH. CONTRS. INC01/31/2023
DOB NOWPlumbingPermit IssuedN.Y. EMS MECHANICAL CORP07/20/2021
BIS—ISSUEDOWNER09/26/2002
BISPLISSUEDBALTER LEHIGH PLMG & HTG CORP09/25/2002
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
08/13/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/06/2021Fail-Final PL - Up to 3 Requested FloorsFailView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
07/02/2021Fire-Resistant Penetrations and JointsGURVINDER SINGHspecial
07/02/2021Energy Code Compliance InspectionsGURVINDER SINGHprogress
07/02/2021HVAC-R and service water piping design and insulationGURVINDER SINGHenergy_progress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/25/2026X00551893-I1Request digital key ↗
08/25/2026X00553818-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/25/2026X00551893-I1Open ↗
08/25/2026X00553818-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/23/2026X00551893-I1Open ↗
08/23/2026X00551893-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026X00551893-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/25/2026X00553818-I1Open ↗