Two family converted from one family
223 STUYVESANT AVENUE
BROOKLYN · BIN 3044926
💬 Discuss this project
1901Year Built
2Stories
B3Building Class
R6BZoning
1,800 sfGross Floor Area
2Units
Two family converted from one family · Owner of record: Einaudi · 1,600 sf lot · 1.13 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof7p · 1 filing · 3 docs
Floor 227p · 4 filings · 20 docs
Floor 123p · 4 filings · 20 docs
Cellar23p · 3 filings · 20 docs
Sub-Basement23p · 4 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/02/2023$1.2M—Private party → EINAUDI, LLC$683/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Me Engineers510/18/2024
Kce Consulting Engineering104/11/2023
Stephenson Roche104/04/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
YBL NY1403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Paradise Construction GroupGeneral Contractor507/08/2026
Nulite Fuel Oilspecialty_contractor107/08/2026
Prime Piping & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Global Arch Design & Builders3397710/18/2024
Building Lifecycle
05/19/2025
Signed off — Alteration
JOB FILE TO INTEROR RENOVATION OF EXISTING 2 FAMILY HOUSE. NO CHANGE USE, OCCUPANCY OR EGRESS.
B00849903-I1
02/03/2025
Signed off — Alteration
INSTALL SPLIT AC UNIT WITHIN EXISTING 2 FAMILY HOUSE.
B00852896-I1
10/25/2024
Permit issued — Mechanical Systems
B00852896-I1-MS
10/18/2024
Filed — Alteration
INSTALL SPLIT AC UNIT WITHIN EXISTING 2 FAMILY HOUSE.
B00852896-P3
10/17/2024
Special inspection requirement — Mechanical Systems
NITHIN JOHN
43 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offNulite Fuel Oil10/25/2024
DOB NOWStructuralSigned-offParadise Construction Group08/23/2024
DOB NOWGeneral ConstructionSigned-offParadise Construction Group02/16/2024
DOB NOWPlumbingSigned-offPrime Piping & Heating09/22/2023
DOB NOWGeneral ConstructionSigned-offParadise Construction Group05/08/2023
1 project · most recent 05/13/2025
General Wiring
FiledStatusContractorScope
05/13/2025CompleteCity Grid ElectricGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
05/20/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/07/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/08/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 24
DateRequirementInspectorRole
10/17/2024Mechanical SystemsNITHIN JOHNspecial
10/17/2024HVAC-R and service water heating system controlsNITHIN JOHNenergy_progress
10/17/2024HVAC-R and service water heating equipmentNITHIN JOHNenergy_progress
10/17/2024HVAC-R and service water piping design and insulationNITHIN JOHNenergy_progress
10/17/2024Duct leakage testing, insulation and designNITHIN JOHNenergy_progress
10/17/2024FinalNITHIN JOHNprogress
08/21/2024Mechanical SystemsNITHIN JOHNspecial
08/21/2024FinalNITHIN JOHNprogress
08/21/2024HVAC-R and service water piping design and insulationNITHIN JOHNenergy_progress
08/21/2024Duct leakage testing, insulation and designNITHIN JOHNenergy_progress
08/21/2024HVAC-R and service water heating equipmentNITHIN JOHNenergy_progress
08/21/2024HVAC-R and service water heating system controlsNITHIN JOHNenergy_progress
04/05/2023Fire-Resistant Penetrations and JointsNITHIN JOHNspecial
03/24/2023FinalNITHIN JOHNprogress
03/24/2023Fire-Resistance Rated ConstructionNITHIN JOHNprogress
03/24/2023Energy Code Compliance InspectionsNITHIN JOHNprogress
03/24/2023Structural Stability – Alterations of existing buildingsNITHIN JOHNspecial
03/24/2023Construction Operations Influencing Adjacent StructuresNITHIN JOHNspecial
03/24/2023Fire-Resistant Penetrations and JointsNITHIN JOHNspecial
03/24/2023Fenestration areasNITHIN JOHNenergy_progress
03/24/2023Fenestration air leakageNITHIN JOHNenergy_progress
03/24/2023Air barrier - visual inspectionNITHIN JOHNenergy_progress
03/24/2023Interior lighting powerNITHIN JOHNenergy_progress
03/24/2023Fenestration and door U-factor and product ratingsNITHIN JOHNenergy_progress
33 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account