| Owner | Filings | Most Recent |
|---|---|---|
| CONCOURSE REALTY | 1 | 03/22/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| BITOPI CONSULTANTS LLC | 2 | 04/24/2025 |
| DARCOM CONSULTANTS LLC | 2 | 03/12/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| MA DESIGNS NYC | 4 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| ALTHAIBANI CORPORATION | General Contractor | 1 | 07/08/2026 |
| SAMUEL & SONS P & H INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| JAY KAVI CORPORATION | 8500 | 2 | 04/24/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Signed-off | SAMUEL & SONS P & H INC | 02/26/2024 |
| DOB NOW | Mechanical Systems | Signed-off | ALTHAIBANI CORPORATION | 02/06/2024 |
| BIS | PL | ISSUED | WAGNER-WEINTRAUB PLUMBING HEATIN | 10/11/1996 |
| BIS | FP | ISSUED | IDEAL FIRE CONTROL | 09/27/1996 |
| BIS | MH | ISSUED | R.O.J. MECHANICAL CORP. | 09/27/1996 |
| BIS | OT | ISSUED | WAGNER WEINTRAUB PLUMBING HTG | 08/21/1996 |
| BIS | FP | ISSUED | MASTER FIRE PREVENTION SYSTEMS | 06/17/1994 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 04/24/2025 | Signed-off | ALTHAIBANI CORPORATION | Heating and Air Conditioning Systems, Refrigeration Systems | Heat / Cool Copeland XFAM-017Z-TFC-081 15,200 BTU · Condensing Unit ×2 XFAM-022Z-TFC-081 20,400 BTU · Condensing Unit ×2 XFAM-045Z-TFC-081 40,700 BTU · Condensing Unit ×2 Fujitsu AOU36RLXFZ 36,000 BTU · Heat Pump Outdoor ×2 Trenton TEHA020E6-HS2B-B 20,000 BTU · Condensing Unit ×2 Refrigeration Copeland XFAL-020Z-TFC-081 15,570 BTU · Condensing Unit ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/24/2025 | Signed-off | SAMUEL & SONS P & H INC | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/14/2024 | Permit Issued | AMERICAN POWER ELECT CONS | 3 meters, 3 new_meters |
| 12/28/2017 | Cancelled | CORE ELECTRICAL CORP | — |
| Date | Type | Result | Report |
|---|---|---|---|
| 03/17/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 09/20/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 08/23/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 08/02/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 08/02/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 04/25/2025 | Fire-Resistant Penetrations and Joints | Jay Kavi | special |
| 04/25/2025 | Mechanical Systems | Jay Kavi | special |
| 04/25/2025 | Final | KAMRUL AHSAN | progress |