← Back
BuildNYC
One family attached or semi-detached
2235 CONEY ISLAND AVENUE
BROOKLYN · BIN 3196658
💬 Discuss this project
1930Year Built
3.5Stories
A5Building Class
R5Zoning
4,296 sfGross Floor Area
1Units
0 Active ViolationsFDNY Report ↗
One family attached or semi-detached · Owner of record: 2235 SDM · 3,000 sf lot · 1.43 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingEquipmentLandscapeGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof2p · 2 filings · 20 docs
Attic24p · 2 filings · 20 docs
Floor 324p · 2 filings · 20 docs
Floor 224p · 2 filings · 20 docs
Floor 1Installation of Heavy Duty Sidewalk Shed28p · 3 filings · 20 docs
CellarTwo family three story residential building29p · 3 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Asr Engineering101/07/2024
Citiscape Consulting906/13/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Citiscape Consulting1803/21/2026
Expediting103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Yafe MeodGeneral Contractor407/08/2026
Topline NYCScaffold303/21/2026
Yafe Meodspecialty_contractor107/08/2026
Nophier Plumbing & HeatingPlumbing107/08/2026
PipestylistsPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Shahrish Shuvo Engineering8524506/13/2023
Demerara Engineering4248203/14/2023
Building Lifecycle
02/28/2025
Permit expired, never signed off — Plumbing
The city's record still shows this permit as issued, with no sign-off on its filing
B00889458-I1-PL
02/20/2025
Permit expired, never signed off — Mechanical Systems
The city's record still shows this permit as issued, with no sign-off on its filing
B00803787-S5-MS
02/20/2025
Permit expired, never signed off — Support of Excavation
The city's record still shows this permit as issued, with no sign-off on its filing
B00803800-I1-SE
01/08/2025
Permit expired, never signed off — Sidewalk Shed
The city's record still shows this permit as issued, with no sign-off on its filing
B00986571-I1-SH
08/24/2024
Permit expired, never signed off — General Construction
The city's record still shows this permit as issued, with no sign-off on its filing
B00803787-I1-GC
73 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedT & T Plumbing02/28/2024
DOB NOWGeneral ConstructionPermit IssuedYafe Meod02/21/2024
DOB NOWMechanical SystemsPermit IssuedYafe Meod02/20/2024
DOB NOWSupport of ExcavationPermit IssuedYafe Meod02/20/2024
DOB NOWSidewalk ShedPermit IssuedTopline NYC01/08/2024
DOB NOWPlumbingPermit IssuedNophier Plumbing & Heating10/20/2023
1 project · most recent 06/13/2023
Gas Storm Water/Sanitary
FiledStatusContractorScope
06/13/2023Permit IssuedT & T PlumbingGas, Storm, Water/Sanitary
3 projects · most recent 05/17/2024
General Wiring
FiledStatusContractorScope
05/17/2024Permit IssuedKJK ElectricGeneral Wiring
01/09/2024Permit IssuedRichard Neu—
08/08/2023Permit IssuedMartin Dorkin—
2 projects · most recent 05/26/2023
Steel Masonry
FiledStatusContractorScope
05/26/2023Permit IssuedYafe MeodSteel, Masonry
05/22/2023Permit IssuedYafe Meod—
1 project · most recent 01/07/2024
Sidewalk Shed
FiledStatusContractorScope
01/07/2024Permit IssuedTopline NYCSidewalk Shed
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
05/17/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/17/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
05/17/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
05/17/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/17/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 48
DateRequirementInspectorRole
06/07/2023Subsurface Investigations (Borings/Test Pits)Shahrish Shuvospecial
06/01/2023Structural Stability – Alterations of existing buildingsOscar Walters Jrspecial
06/01/2023MasonryOscar Walters Jrspecial
06/01/2023Fire-Resistant Penetrations and JointsOscar Walters Jrspecial
06/01/2023Concrete - Cast-In-PlaceOscar Walters Jrspecial
06/01/2023Construction Operations Influencing Adjacent StructuresOscar Walters Jrspecial
06/01/2023Energy Code Compliance InspectionsOscar Walters Jrprogress
06/01/2023Fire-Resistance Rated ConstructionOscar Walters Jrprogress
06/01/2023Fenestration and door U-factor and product ratingsShahrish Shuvoenergy_progress
06/01/2023Air barrier — testing Shahrish Shuvoenergy_progress
06/01/2023Exterior lighting powerShahrish Shuvoenergy_progress
06/01/2023Lighting in dwelling unitsShahrish Shuvoenergy_progress
06/01/2023Insulation placement and R valuesShahrish Shuvoenergy_progress
06/01/2023Fenestration air leakageShahrish Shuvoenergy_progress
06/01/2023Protection of exposed foundation insulationShahrish Shuvoenergy_progress
06/01/2023Permanent certificateShahrish Shuvoenergy_progress
06/01/2023Lighting controlsShahrish Shuvoenergy_progress
06/01/2023MeteringShahrish Shuvoenergy_progress
06/01/2023Fenestration areasShahrish Shuvoenergy_progress
06/01/2023Air barrier - visual inspectionShahrish Shuvoenergy_progress
06/01/2023Electric vehicle service equipment requirementsShahrish Shuvoenergy_progress
06/01/2023Maintenance informationShahrish Shuvoenergy_progress
06/01/2023Interior lighting powerShahrish Shuvoenergy_progress
06/01/2023Subgrade InspectionsOscar Walters Jrspecial
05/22/2023FinalShahrish Shuvoprogress
Latest 25 of 48.
54 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account