← Back
One story - permanent living quarter
224-07 76 ROAD
QUEENS · BIN 4165498
💬 Discuss this project
1960Year Built
1Stories
A2Building Class
R2AZoning
1,248 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One story - permanent living quarter · 4,042 sf lot · 0.31 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Cellar3p · 2 filings · 18 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
AV FIRST REALTY707/08/2026
HANG REALTY INC.403/22/2026
HONG REALTY INC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/13/2022$998K—HANG REALTY INC. → Private party$800/sf building
03/13/2019$362K—Private party → HANG REALTY INC.$290/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
L & C ASSOCIATES408/04/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
L&C ASSOCIATES403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRISTAR DEVELOPING INCGeneral Contractor107/08/2026
TRI CITY MECHANICAL GROUP CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LAM &CO CONSULTING LLC DB2159208/03/2021
Building Lifecycle
All (24)Filed (4)Permit Issued (2)Violation (7)Inspection (5)Special Inspection (6)
10/08/2021
Violation issued (ECB, closed)
Construction
09/08/2021
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/27/2021
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
08/12/2021
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/06/2021
Special inspection requirement — Energy Code Compliance Inspections
RONNY LAM
08/04/2021
Filed — Alteration
PLUMBING WORK AT EXISTING 1 STORY HOUSE CELLAR AND BACKYARD AS PER PLAN. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THIS APPLICATION. RESOLVING VIOLATION 34534235M, 35446323Z, 35522285Z, 35525937Z
Q00467687-P1
08/04/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
RONNY LAM
08/04/2021
Special inspection requirement — Energy Code Compliance Inspections
RONNY LAM
08/03/2021
Filed — Alteration
INTERIOR RENOVATION AT EXISTING 1 STORY HOUSE CELLAR AND BACKYARD AS PER PLAN. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THIS APPLICATION. RESOLVING VIOLATION 34534235M, 35446323Z, 35522285Z, 35525937Z
Q00467630-P1
07/16/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
RONNY LAM
07/16/2021
Special inspection requirement — Energy Code Compliance Inspections
RONNY LAM
07/16/2021
Special inspection requirement — Energy Code Compliance Inspections
RONNY LAM
07/09/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/09/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/13/2021
Permit issued — Plumbing
Q00467687-I1-PL
05/10/2021
Permit issued — General Construction
Q00467630-I1-GC
04/14/2021
Violation issued (ECB, closed)
Construction
02/15/2021
Filed — Alteration
PLUMBING WORK AT EXISTING 1 STORY HOUSE CELLAR AND BACKYARD AS PER PLAN. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THIS APPLICATION. RESOLVING VIOLATION 34534235M, 35446323Z, 35522285Z, 35525937Z
Q00467687-I1
02/11/2021
Filed — Alteration
INTERIOR RENOVATION AT EXISTING 1 STORY HOUSE CELLAR AND BACKYARD AS PER PLAN. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THIS APPLICATION. RESOLVING VIOLATION 34534235M, 35446323Z, 35522285Z, 35525937Z
Q00467630-I1
01/15/2021
Violation issued (ECB, closed)
Construction
10/23/2020
Violation issued (ECB, closed)
Construction
09/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/02/2020
Violation issued (ECB, closed)
Construction
09/01/2006
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedFLAVIO MECHANICAL CORP05/13/2021
DOB NOWGeneral ConstructionSigned-offTRISTAR DEVELOPING INC05/10/2021
1 project · most recent 08/04/2021
Gas Water/Sanitary
FiledStatusContractorScope
08/04/2021Permit IssuedTRI CITY MECHANICAL GROUPGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
09/08/2021Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/27/2021Pass-Final General Construction Non-Directive 14PassView ↗
08/12/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/09/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/09/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
08/06/2021Energy Code Compliance InspectionsRONNY LAMprogress
08/04/2021Fire-Resistant Penetrations and JointsRONNY LAMspecial
08/04/2021Energy Code Compliance InspectionsRONNY LAMprogress
07/16/2021Fire-Resistant Penetrations and JointsRONNY LAMspecial
07/16/2021Energy Code Compliance InspectionsRONNY LAMprogress
07/16/2021Energy Code Compliance InspectionsRONNY LAMprogress
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch - Plumbing2
08/27/2026Q00467687-I1Request digital key ↗
08/15/2026Q00467687-P1Request digital key ↗
▸DOB NOWPlans/Sketch - General Construction2
08/27/2026Q00467630-I1Request digital key ↗
08/27/2026Q00467630-P1Request digital key ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/27/2026Q00467630-I1Open ↗
08/27/2026Q00467630-P1Open ↗
08/27/2026Q00467687-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026Q00467687-I1Open ↗
08/29/2026Q00467687-P1Open ↗
08/27/2026Q00467630-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/27/2026Q00467630-I1Open ↗
08/25/2026Q00467630-P1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/27/2026Q00467630-P1Open ↗
08/27/2026Q00467630-I1Open ↗
08/27/2026Q00467687-P1Open ↗
Showing 3 of 4 on file for this type