← Back
Primarily 1 family with 1 store or office
224 VARICK STREET
MANHATTAN · BIN 1008401
💬 Discuss this project
1910Year Built
2.5Stories
S1Building Class
C2-6Zoning
1,500 sfGross Floor Area
2Units
Rent Stabilized9 Open Violations ▸
Primarily 1 family with 1 store or office · Owner of record: 224 VARICK STREET LLC · 600 sf lot · 2.5 FAR built · Flood zone X500
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KINSEY EQUITIES207/08/2026
224 VARRICK STREET LLC403/22/2026
KINSEY903/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LEON SKVIRSKY PE104/21/2026
CORE STATES GROUP202/03/2026
COLWELL GROUP, INC101/21/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A1 EXPEDITING SERVICE CORP.603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GRAVESEND CONSTRUCTION COGeneral Contractor207/08/2026
ALLAN TANGElectrical103/21/2026
FREDERICK LEEElectrical103/21/2026
A ELECTRICAL MAIN SVC INCElectrical103/22/2026
JOHN FITZGERALD PLBG &HTGPlumbing107/08/2026
PAUL SIGNSScaffold107/08/2026
MICHAEL BAPTISTEElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MILROSE CONSULTANTS LLC2003302/03/2026
Building Lifecycle
All (39)Filed (4)Permit Issued (4)Signed Off (3)Violation (18)Inspection (5)Special Inspection (5)
08/10/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/31/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
05/12/2026
Signed off — Alteration
Removal and installation of interior non bearing partitions and related finishes as per plans filed herewith. No change in use, egress or occupancy under this application.
M01331692-I1
05/08/2026
Signed off — Alteration
Modification to existing Plumbing system as per plans filed herewith. No change in use, egress or occupancy under this application.
M01334031-I1
05/08/2026
Signed off — Alteration
M01334008-I1
04/30/2026
Permit issued — Sign
M01378607-I1-SG
04/21/2026
Filed — Alteration
INSTALL EXTERIOR ILLUMINATED WALL SIGN ( SWEETSPOT DISPENSARY)
M01378607-I1
03/26/2026
Special inspection requirement — Final
LEON SKVIRSKY
03/23/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/23/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/20/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/13/2026
Permit issued — Plumbing
M01334031-I1-PL
02/05/2026
Permit issued — Mechanical Systems
M01334008-I1-MS
02/05/2026
Permit issued — General Construction
M01331692-I1-GC
02/03/2026
Filed — Alteration
Modification to existing Plumbing system as per plans filed herewith. No change in use, egress or occupancy under this application.
M01334031-I1
02/03/2026
Filed — Alteration
M01334008-I1
01/21/2026
Filed — Alteration
Removal and installation of interior non bearing partitions and related finishes as per plans filed herewith. No change in use, egress or occupancy under this application.
M01331692-I1
01/13/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Drutjons
01/06/2026
Special inspection requirement — Tenant Protection Plan Compliance
Christopher Drutjons
12/10/2025
Special inspection requirement — Tenant Protection Plan Compliance
Christopher Drutjons
12/10/2025
Special inspection requirement — Final
Dennis Colwell
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/14/2023
Violation issued (ECB, closed)
Construction
04/14/2023
Violation issued (ECB, closed)
Construction
04/14/2023
Violation issued (ECB, closed)
Construction
04/14/2023
Violation issued (ECB, closed)
Construction
11/08/2019
Violation issued (HPD, closed)
I
11/08/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/06/2018
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/12/2018
Violation issued (HPD, closed)
I
05/15/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/31/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/28/2001
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSignPermit IssuedPAUL SIGNS, INC04/30/2026
DOB NOWPlumbingSigned-offJOHN FITZGERALD PLBG &HTG02/13/2026
DOB NOWMechanical SystemsSigned-offGRAVESEND CONSTRUCTION CO02/05/2026
DOB NOWGeneral ConstructionSigned-offGRAVESEND CONSTRUCTION CO02/05/2026
BISOTISSUEDHITIME CONSTRUCTION INC06/24/2015
BIS—ISSUEDPAUL SIGNS, INC02/11/2013
BISOTISSUEDSIGNS CAD CORP06/24/2011
BISPLISSUEDSAFETY PLMBG & HTG LLC03/21/2001
BISEQISSUEDROCKLEDGE SCAFFOLD CORP01/25/2001
BISEQISSUEDATHERAS CONSTRUCTION CORP01/23/2001
BIS—ISSUEDATHERAS CONSTRUCTION CORP01/23/2001
BIS—ISSUEDMANDL INC04/04/1997
BISPLISSUEDMJM PLUUMBING INC04/04/1997
1 project · most recent 02/03/2026
Water/Sanitary
FiledStatusContractorScope
02/03/2026Signed-offJOHN FITZGERALD PLBG &HTGWater/Sanitary
3 projects · most recent 05/01/2026
HVAC Wiring
FiledStatusContractorScope
05/01/2026Permit IssuedLIMITLESS ELECT RESOURCES—
02/14/2026CompleteCL ELECTRICAL CORP—
09/01/2025CompleteA ELECTRICAL MAIN SVC INCHVAC Wiring
1 project · most recent 01/21/2026
Tenant Protection Plan 72 Hour
FiledStatusContractorScope
01/21/2026Signed-offGRAVESEND CONSTRUCTION COTenant Protection Plan 72 Hour
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
08/10/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/31/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
03/23/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/23/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/20/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
03/26/2026FinalLEON SKVIRSKYprogress
01/13/2026Fire-Resistant Penetrations and JointsChristopher Drutjonsspecial
01/06/2026Tenant Protection Plan ComplianceChristopher Drutjonsspecial
12/10/2025Tenant Protection Plan ComplianceChristopher Drutjonsspecial
12/10/2025FinalDennis Colwellprogress
▾Documents — 54 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/19/2026M01331692-I1Request digital key ↗
08/19/2026M01334008-I1Request digital key ↗
08/19/2026M01334031-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits7
▸BISPLAN / WORK APPROVAL APPLICATION4
05/27/2016140365646Open ↗
06/23/2015140365646Open ↗
02/07/2013121518063Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION3
06/23/2015140365646Open ↗
02/14/2013121518063Open ↗
06/28/2011120550402Open ↗
▸Seals & Professional Certifications17
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
07/29/2016140365646Open ↗
07/29/2016140365646Open ↗
04/08/2013121518063Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/17/2026M01378607-I1Open ↗
08/13/2026M01334008-I1Open ↗
08/13/2026M01331692-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026M01378607-I1Open ↗
08/28/2026M01331692-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026M01331692-I1Open ↗
08/28/2026M01334031-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
06/23/2015140365646Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
02/07/2013121518063Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
06/23/2015140365646Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
02/07/2013121518063Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
06/23/2015140365646Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/17/2026M01378607-I1Open ↗
08/13/2026M01331692-I1Open ↗
08/13/2026M01334008-I1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
12/29/2010120550402Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
06/23/2015140365646Open ↗
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)1
02/07/2013121518063Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
07/29/2016140365646Open ↗
07/29/2016140365646Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
07/29/2016140365646Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
06/23/2015140365646Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
06/23/2015140365646Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
06/23/2015140365646Open ↗
▸Approvals, Objections & Sign-offs5
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
07/29/2016140365646Open ↗
04/08/2013121518063Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
02/07/2013121518063Open ↗
12/29/2010120550402Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
07/29/2016140365646Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT5
07/29/2016140365646Open ↗
06/23/2015140365646Open ↗
04/08/2013121518063Open ↗
Showing 3 of 5 on file for this type
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET2
02/07/2013121518063Open ↗
12/29/2010120550402Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
06/23/2015140365646Open ↗