← Back
Two stories - detached, small or mid-size
225-25 105 AVENUE
QUEENS · Queens Village · BIN 4240958
💬 Discuss this project
1935Year Built
2.5Stories
A1Building Class
R2Zoning
1,584 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 2,800 sf lot · 0.57 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof3p · 1 filing · 12 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/24/2017$439K—Private party → Private party$277/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GREEN RIVER ENVIRONMENTAL ENGINEERI208/20/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NY State Solar LLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NYSS LLCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GREEN RIVER ENVIRONMENTAL7841208/20/2026
Building Lifecycle
All (12)Filed (2)Permit Issued (1)Special Inspection (9)
08/20/2026
Filed — Alteration
INSTALLATION OF PHOTOVOLTAIC SOLAR ARRAY ON EXISTING ROOF SYSTEM AS PER PLANS.
Q01279861-P1
08/10/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT MASONE
08/10/2026
Special inspection requirement — Energy Code Compliance Inspections
ROBERT MASONE
08/10/2026
Special inspection requirement — Final
ROBERT MASONE
08/10/2026
Special inspection requirement — Air barrier - visual inspection
ROBERT MASONE
09/04/2025
Permit issued — Solar
Q01279861-I1-SL
09/02/2025
Filed — Alteration
INSTALLATION OF PHOTOVOLTAIC SOLAR ARRAY ON EXISTING ROOF SYSTEM AS PER PLANS.
Q01279861-I1
08/29/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT MASONE
08/29/2025
Special inspection requirement — Air barrier - visual inspection
ROBERT MASONE
08/29/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
ROBERT MASONE
08/29/2025
Special inspection requirement — Energy Code Compliance Inspections
ROBERT MASONE
08/29/2025
Special inspection requirement — Final
ROBERT MASONE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offNYSS LLC09/04/2025
1 project · most recent 09/02/2025
FiledStatusContractorScope
09/02/2025CompleteNY SOLAR ELECTRICAL LLC—
1 project · most recent 08/20/2026
FiledStatusContractorScope
08/20/2026Signed-offNYSS LLC46 panels, 20.02 kw, 1,270 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
08/10/2026Fire-Resistant Penetrations and JointsROBERT MASONEspecial
08/10/2026Energy Code Compliance InspectionsROBERT MASONEprogress
08/10/2026FinalROBERT MASONEprogress
08/10/2026Air barrier - visual inspectionROBERT MASONEenergy_progress
08/29/2025Fire-Resistant Penetrations and JointsROBERT MASONEspecial
08/29/2025Air barrier - visual inspectionROBERT MASONEenergy_progress
08/29/2025Structural Stability – Alterations of existing buildingsROBERT MASONEspecial
08/29/2025Energy Code Compliance InspectionsROBERT MASONEprogress
08/29/2025FinalROBERT MASONEprogress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/19/2026Q01279861-P1Request digital key ↗
08/19/2026Q01279861-I1Request digital key ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature4
08/28/2026Q01279861-P1Open ↗
08/28/2026Q01279861-P1Open ↗
08/24/2026Q01279861-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/22/2026Q01279861-P1Open ↗
08/19/2026Q01279861-P1Open ↗
08/13/2026Q01279861-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026Q01279861-P1Open ↗
08/24/2026Q01279861-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/19/2026Q01279861-P1Open ↗
08/13/2026Q01279861-I1Open ↗