← Back
BuildNYC
Two family brick
225 BAY 41 STREET
BROOKLYN · BIN 3186725
💬 Discuss this project
1930Year Built
2Stories
B1Building Class
R5Zoning
2,280 sfGross Floor Area
2Units
Two family brick · 2,248 sf lot · 1.01 FAR built · Flood zone X500
Locations of Work
ArchitecturePlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 25p · 2 filings · 20 docs
Floor 17p · 2 filings · 20 docs
Cellar5p · 2 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/18/2021$1.1M—Private party → Private party$482/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
M-Con Engineering506/28/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Integrity UV 168403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
M J Design and BuildGeneral Contractor303/21/2026
American Standard P&H CororpPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
M-Con Engineering7341506/28/2022
Building Lifecycle
08/01/2022
Signed off — Alteration
RENOVATION OF AN TWO STORY BRICK WITH CELLAR HOUSE, PARTITION WORK AS PER PLAN, PLUMBING WORK WILL BE FILED UNDER SEPARATE APPLICATION. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00627910-I1
08/01/2022
Signed off — Alteration
FILING PLUMBING WORK AS PER PLAN IN CONJUNCTION WITH DOB APPLICATION# B00627910. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00631106-I1
07/01/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
06/29/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Michelle Contri
06/29/2022
Special inspection requirement — Energy Code Compliance Inspections
Michelle Contri
24 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAmerican Standard P&H Cororp11/18/2021
DOB NOWGeneral ConstructionSigned-offM J Design and Build11/15/2021
1 project · most recent 11/23/2021
General Wiring
FiledStatusContractorScope
11/23/2021CompleteKJK ElectricGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
07/01/2022Pass-Final General Construction Non-Directive 14PassView ↗
06/10/2022No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
03/01/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/01/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
06/29/2022Fire-Resistant Penetrations and JointsMichelle Contrispecial
06/29/2022Energy Code Compliance InspectionsMichelle Contriprogress
06/29/2022Fire-Resistance Rated ConstructionMichelle Contriprogress
06/26/2022Fire-Resistant Penetrations and JointsMichelle Contrispecial
06/26/2022Energy Code Compliance InspectionsMichelle Contriprogress
06/26/2022Fire-Resistance Rated ConstructionMichelle Contriprogress
05/25/2022Fire-Resistant Penetrations and JointsMichelle Contrispecial
05/25/2022Energy Code Compliance InspectionsMichelle Contriprogress
05/25/2022HVAC-R and service water heating equipmentMichelle Contrienergy_progress
05/25/2022HVAC-R and service water heating system controlsMichelle Contrienergy_progress
05/25/2022HVAC-R and service water piping design and insulationMichelle Contrienergy_progress
27 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account