← Back
Over six families without stores
225 EAST 202 STREET
BRONX · Bedford Park · BIN 2017242
💬 Discuss this project
1927Year Built
5Stories
C1Building Class
R8Zoning
36,200 sfGross Floor Area
43Units
LL97 CoveredRent Stabilized13 Open Violations ▸FDNY Report ↗
Over six families without stores · Owner of record: 202 STREET LLC · 10,000 sf lot · 3.62 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Floor 54p · 1 filing · 4 docs
Floor 44p · 1 filing · 4 docs
Floor 34p · 1 filing · 4 docs
Floor 24p · 1 filing · 4 docs
Floor 14p · 1 filing · 4 docs
Cellar13p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
202 STREET LLC303/22/2026
202ND STREET LLC103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NEW YORK ENGINEERING ASSOC., P.C.508/31/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NEW YORK ENGINEERING ASSOCIATES P1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ACE-ATLAS PLBING & HTGPlumbing607/08/2026
ACE ATLAS CORPORATIONGeneral Contractor307/08/2026
IMPACT PLUMBING INCPlumbing203/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW YORK ENGINEERING ASSO851508/31/2021
Building Lifecycle
All (56)Filed (5)Permit Issued (8)Signed Off (3)Violation (30)Special Inspection (10)
03/13/2025
Violation issued (HPD, open)
B
03/13/2025
Violation issued (HPD, closed)
C
03/13/2025
Violation issued (HPD, closed)
B
03/13/2025
Violation issued (HPD, closed)
B
03/13/2025
Violation issued (HPD, open)
B
03/13/2025
Violation issued (HPD, open)
C
12/01/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/22/2022
Signed off — Alteration
INSTALL CHIMNEY LINER PER PLANS.
X00453630-I1
02/22/2022
Signed off — Alteration
REPLACE BOILER AND OIL BURNER WITH BOILER AND GAS BURNER. REMOVE OIL TANK.
X00453401-I1
02/22/2022
Signed off — Alteration
INSTALL NEW GAS SERVICE, METER AND PIPING AND CONNECT TO REPLACMEENT BOILER/BURNER.
X00441069-I1
01/19/2022
Violation issued (HPD, closed)
C
08/31/2021
Filed — Alteration
REPLACE BOILER AND OIL BURNER WITH BOILER AND GAS BURNER. REMOVE OIL TANK.
X00453401-P1
08/31/2021
Special inspection requirement — HVAC-R and service water heating system controls
LOUIS ARENA
08/31/2021
Special inspection requirement — Maintenance information
LOUIS ARENA
08/31/2021
Special inspection requirement — HVAC-R and service water heating equipment
LOUIS ARENA
08/31/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
LOUIS ARENA
08/31/2021
Special inspection requirement — Heating Systems
LOUIS ARENA
08/30/2021
Filed — Alteration
INSTALL NEW GAS SERVICE, METER AND PIPING AND CONNECT TO REPLACMEENT BOILER/BURNER.
X00441069-P1
08/24/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
LOUIS ARENA
08/24/2021
Special inspection requirement — Heating Systems
LOUIS ARENA
08/24/2021
Special inspection requirement — Maintenance information
LOUIS ARENA
08/24/2021
Special inspection requirement — HVAC-R and service water heating equipment
LOUIS ARENA
08/24/2021
Special inspection requirement — HVAC-R and service water heating system controls
LOUIS ARENA
07/21/2021
Permit issued — Plumbing
X00441069-I1-PL
07/21/2021
Permit issued — Boiler Equipment
X00453401-I1-BE
04/29/2021
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/28/2021
Permit issued — Mechanical Systems
X00453630-I1-MS
04/28/2021
Permit issued — Boiler Equipment
X00453401-I1-BE
04/28/2021
Permit issued — Plumbing
X00441069-I1-PL
04/02/2021
Violation issued (HPD, closed)
A
03/10/2021
Permit issued — Plumbing
X00441069-I1-PL
03/09/2021
Permit issued — Boiler Equipment
X00453401-I1-BE
02/19/2021
Permit issued — Mechanical Systems
X00453630-I1-MS
01/21/2021
Filed — Alteration
INSTALL CHIMNEY LINER PER PLANS.
X00453630-I1
01/21/2021
Filed — Alteration
REPLACE BOILER AND OIL BURNER WITH BOILER AND GAS BURNER. REMOVE OIL TANK.
X00453401-I1
01/21/2021
Filed — Alteration
INSTALL NEW GAS SERVICE, METER AND PIPING AND CONNECT TO REPLACMEENT BOILER/BURNER.
X00441069-I1
03/05/2018
Violation issued (HPD, open)
A
03/05/2018
Violation issued (HPD, closed)
B
03/05/2018
Violation issued (HPD, closed)
A
03/05/2018
Violation issued (HPD, closed)
A
03/05/2018
Violation issued (HPD, closed)
A
03/05/2018
Violation issued (HPD, closed)
A
03/05/2018
Violation issued (HPD, closed)
B
11/23/2015
Violation issued (HPD, closed)
B
04/07/2014
Violation issued (HPD, closed)
C
12/26/2013
Violation issued (HPD, closed)
B
05/11/2007
Violation issued (HPD, open)
B
05/11/2007
Violation issued (HPD, open)
A
05/11/2007
Violation issued (HPD, open)
B
05/11/2007
Violation issued (HPD, open)
B
05/11/2007
Violation issued (HPD, open)
B
05/11/2007
Violation issued (HPD, open)
B
05/11/2007
Violation issued (HPD, open)
B
05/11/2007
Violation issued (HPD, open)
B
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/17/1992
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offACE-ATLAS PLBING & HTG07/21/2021
DOB NOWBoiler EquipmentSigned-offACE-ATLAS PLBING & HTG07/21/2021
DOB NOWMechanical SystemsSigned-offACE ATLAS CORPORATION04/28/2021
DOB NOWBoiler EquipmentSigned-offACE-ATLAS PLBING & HTG04/28/2021
DOB NOWPlumbingSigned-offACE-ATLAS PLBING & HTG04/28/2021
DOB NOWPlumbingSigned-offACE-ATLAS PLBING & HTG03/10/2021
DOB NOWBoiler EquipmentSigned-offACE-ATLAS PLBING & HTG03/09/2021
DOB NOWMechanical SystemsSigned-offACE ATLAS CORPORATION02/19/2021
BISOTISSUEDDOLMEN CONTRACTING CORP12/08/2010
BISEQISSUEDEVEREST SCAFFOLDING INC08/26/2010
BISEQISSUEDLAUREDA CONSTRUCTION INC.06/17/2005
1 project · most recent 07/06/2021
Boiler Controls
FiledStatusContractorScope
07/06/2021CompleteSTX ELECTRICAL CORPBoiler Controls
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
08/31/2021HVAC-R and service water heating system controlsLOUIS ARENAenergy_progress
08/31/2021Maintenance informationLOUIS ARENAenergy_progress
08/31/2021HVAC-R and service water heating equipmentLOUIS ARENAenergy_progress
08/31/2021Fire-Resistant Penetrations and JointsLOUIS ARENAspecial
08/31/2021Heating SystemsLOUIS ARENAspecial
08/24/2021Fire-Resistant Penetrations and JointsLOUIS ARENAspecial
08/24/2021Heating SystemsLOUIS ARENAspecial
08/24/2021Maintenance informationLOUIS ARENAenergy_progress
08/24/2021HVAC-R and service water heating equipmentLOUIS ARENAenergy_progress
08/24/2021HVAC-R and service water heating system controlsLOUIS ARENAenergy_progress
▾Documents — 54 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch - Plumbing2
08/25/2026X00441069-I1Request digital key ↗
08/15/2026X00441069-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Boiler Equipment2
08/25/2026X00453401-I1Request digital key ↗
08/15/2026X00453401-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/25/2026X00453630-I1Request digital key ↗
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION3
10/04/2010220075727Open ↗
08/31/2010220079670Open ↗
08/05/2010220075727Open ↗
▸BISWORK PERMIT APPLICATION2
12/08/2010220075727Open ↗
08/31/2010220079670Open ↗
▸Seals & Professional Certifications19
▸DOB NOWProgress Inspector Seal & Signature6
09/23/2026X00453401-I1Open ↗
09/23/2026X00453401-I1Open ↗
09/23/2026X00453401-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/25/2026X00441069-I1Open ↗
08/25/2026X00441069-P1Open ↗
08/13/2026X00453630-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/23/2026X00453401-I1Open ↗
09/01/2026X00441069-P1Open ↗
08/26/2026X00453401-P1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
08/06/2011220075727Open ↗
12/08/2010220075727Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
08/31/2010220079670Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
08/31/2010220079670Open ↗
▸Safety & Tenant Protection2
▸DOB NOWTenant Protection Plan2
08/13/2026X00441069-I1Open ↗
08/13/2026X00441069-P1Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/25/2026X00441069-P1Open ↗
08/25/2026X00441069-I1Open ↗
08/13/2026X00453630-I1Open ↗
Showing 3 of 5 on file for this type
▸BISDEP ASBESTOS PROJECT COMPLETION FORM2
12/08/2010220075727Open ↗
08/05/2010220075727Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
08/31/2010220079670Open ↗
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026X00453401-I1Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026X00453401-I1Open ↗
▸Approvals, Objections & Sign-offs4
▸BISADMINISTRATIVE OBJECTIONS2
08/31/2010220079670Open ↗
08/05/2010220075727Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
08/05/2011220075727Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
08/05/2011220075727Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
08/16/2011220075727Open ↗
08/05/2010220075727Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
08/31/2010220079670Open ↗
08/05/2010220075727Open ↗
▸Other Documents5
▸DOB NOWDHCR Document5
08/13/2026X00453630-I1Open ↗
08/13/2026X00453401-P1Open ↗
08/13/2026X00441069-P1Open ↗
Showing 3 of 5 on file for this type