← Back
Primarily 2 family with 1 store or office
2258 WEBSTER AVENUE
BRONX · Belmont · BIN 2011166
💬 Discuss this project
1913Year Built
3Stories
S2Building Class
R7-1Zoning
3,240 sfGross Floor Area
3Units
1 Open Violation ▸
Primarily 2 family with 1 store or office · 1,620 sf lot · 2 FAR built · Flood zone X
Locations of Work
Plumbing
Cellar1p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HPL ENGINEERING P.C.503/18/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JM CONSULTANT STUDIO1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CATMAN PLUMBING INCPlumbing607/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HPL ENGINEERING PC5613503/18/2022
Building Lifecycle
All (48)Filed (5)Permit Issued (2)Signed Off (2)Violation (3)Inspection (8)Special Inspection (28)
10/12/2022
Signed off — Alteration
PROPOSED PL WORK AT THE COMMERCIAL KITCHEN OF EATING & DRINKING ESTABLISHMENT. TO INSTALL NEW GAS METER, 3 HW HEATER AT CEL. RELOCATE 2 BOILER AT CEL. CAP & REMOVE EX. HW HEATER AT CEL. REQUEST GAS AUTHORIZATION DUE TO UTILITY COMPANY SHUT OFF EX. METERS.
X00473076-I1
10/12/2022
Signed off — Alteration
PROPOSED BOILER WORK IN-CONJUNCTION WITH DOBNow PLUMBING APPLICATION #: X00473076. RELOCATE 2 BOILER AT CELLAR FOR DWELLING UNITS ON 2ND & 3RD FL. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
X00473080-I1
03/21/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Fran Huang
03/21/2022
Special inspection requirement — HVAC-R and service water heating system controls
Fran Huang
03/21/2022
Special inspection requirement — HVAC-R and service water heating equipment
Fran Huang
03/21/2022
Special inspection requirement — Maintenance information
Fran Huang
03/21/2022
Special inspection requirement — Energy Code Compliance Inspections
Fran Huang
03/21/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Fran Huang
03/18/2022
Filed — Alteration
PROPOSED PL WORK AT THE COMMERCIAL KITCHEN OF EATING & DRINKING ESTABLISHMENT. TO INSTALL NEW GAS METER, 3 HW HEATER AT CEL. RELOCATE 2 BOILER AT CEL. CAP & REMOVE EX. HW HEATER AT CEL. REQUEST GAS AUTHORIZATION DUE TO UTILITY COMPANY SHUT OFF EX. METERS.
X00473076-P3
03/17/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Fran Huang
03/17/2022
Special inspection requirement — Energy Code Compliance Inspections
Fran Huang
03/17/2022
Special inspection requirement — HVAC-R and service water heating equipment
Fran Huang
03/17/2022
Special inspection requirement — Maintenance information
Fran Huang
03/17/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Fran Huang
03/17/2022
Special inspection requirement — HVAC-R and service water heating system controls
Fran Huang
03/03/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/24/2022
Filed — Alteration
PROPOSED PL WORK AT THE COMMERCIAL KITCHEN OF EATING & DRINKING ESTABLISHMENT. TO INSTALL NEW GAS METER, 3 HW HEATER AT CEL. RELOCATE 2 BOILER AT CEL. CAP & REMOVE EX. HW HEATER AT CEL. REQUEST GAS AUTHORIZATION DUE TO UTILITY COMPANY SHUT OFF EX. METERS.
X00473076-P2
02/24/2022
Special inspection requirement — HVAC-R and service water heating system controls
Fran Huang
02/24/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Fran Huang
02/24/2022
Special inspection requirement — HVAC-R and service water heating equipment
Fran Huang
02/24/2022
Special inspection requirement — Maintenance information
Fran Huang
02/24/2022
Special inspection requirement — Energy Code Compliance Inspections
Fran Huang
02/24/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Fran Huang
02/16/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/10/2021
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/24/2021
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/24/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/18/2021
Filed — Alteration
PROPOSED PL WORK AT THE COMMERCIAL KITCHEN OF EATING & DRINKING ESTABLISHMENT. TO INSTALL NEW GAS METER, 3 HW HEATER AT CEL. RELOCATE 2 BOILER AT CEL. CAP & REMOVE EX. HW HEATER AT CEL. REQUEST GAS AUTHORIZATION DUE TO UTILITY COMPANY SHUT OFF EX. METERS.
X00473076-P1
11/17/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Fran Huang
11/17/2021
Special inspection requirement — Energy Code Compliance Inspections
Fran Huang
11/17/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
Fran Huang
11/17/2021
Special inspection requirement — HVAC-R and service water heating equipment
Fran Huang
11/17/2021
Special inspection requirement — Maintenance information
Fran Huang
11/17/2021
Special inspection requirement — HVAC-R and service water heating system controls
Fran Huang
10/14/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/01/2021
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
09/22/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
08/25/2021
Permit issued — Boiler Equipment
X00473080-I1-BE
08/25/2021
Permit issued — Plumbing
X00473076-I1-PL
02/24/2021
Filed — Alteration
PROPOSED PL WORK AT THE COMMERCIAL KITCHEN OF EATING & DRINKING ESTABLISHMENT. TO INSTALL NEW GAS METER, 3 HW HEATER AT CEL. RELOCATE 2 BOILER AT CEL. CAP & REMOVE EX. HW HEATER AT CEL. REQUEST GAS AUTHORIZATION DUE TO UTILITY COMPANY SHUT OFF EX. METERS.
X00473076-I1
02/24/2021
Filed — Alteration
PROPOSED BOILER WORK IN-CONJUNCTION WITH DOBNow PLUMBING APPLICATION #: X00473076. RELOCATE 2 BOILER AT CELLAR FOR DWELLING UNITS ON 2ND & 3RD FL. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
X00473080-I1
02/24/2021
Special inspection requirement — Heating Systems
Fran Huang
02/24/2021
Special inspection requirement — HVAC-R and service water heating equipment
Fran Huang
02/24/2021
Special inspection requirement — HVAC-R and service water heating system controls
Fran Huang
02/24/2021
Special inspection requirement — Maintenance information
Fran Huang
06/03/2010
Violation issued (ECB, closed)
Construction
05/13/2005
Violation issued (HPD, open)
B
01/21/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWBoiler EquipmentSigned-offCATMAN PLUMBING INC08/25/2021
DOB NOWPlumbingSigned-offCATMAN PLUMBING INC08/25/2021
BISPLISSUEDMONARCH MECHANICAL INC01/19/2005
BISPLISSUEDWAGNER-WEINTRAUB PLBG. & HTG EN05/20/1997
BISFPISSUEDMASTER FIRE PREVENTION SYSTEMS I10/23/1996
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
03/03/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/16/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/10/2021Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/24/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/24/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/14/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/01/2021Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/22/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 28
DateRequirementInspectorRole
03/21/2022HVAC-R and service water piping design and insulationFran Huangenergy_progress
03/21/2022HVAC-R and service water heating system controlsFran Huangenergy_progress
03/21/2022HVAC-R and service water heating equipmentFran Huangenergy_progress
03/21/2022Maintenance informationFran Huangenergy_progress
03/21/2022Energy Code Compliance InspectionsFran Huangprogress
03/21/2022Fire-Resistant Penetrations and JointsFran Huangspecial
03/17/2022Fire-Resistant Penetrations and JointsFran Huangspecial
03/17/2022Energy Code Compliance InspectionsFran Huangprogress
03/17/2022HVAC-R and service water heating equipmentFran Huangenergy_progress
03/17/2022Maintenance informationFran Huangenergy_progress
03/17/2022HVAC-R and service water piping design and insulationFran Huangenergy_progress
03/17/2022HVAC-R and service water heating system controlsFran Huangenergy_progress
02/24/2022HVAC-R and service water heating system controlsFran Huangenergy_progress
02/24/2022HVAC-R and service water piping design and insulationFran Huangenergy_progress
02/24/2022HVAC-R and service water heating equipmentFran Huangenergy_progress
02/24/2022Maintenance informationFran Huangenergy_progress
02/24/2022Energy Code Compliance InspectionsFran Huangprogress
02/24/2022Fire-Resistant Penetrations and JointsFran Huangspecial
11/17/2021Fire-Resistant Penetrations and JointsFran Huangspecial
11/17/2021Energy Code Compliance InspectionsFran Huangprogress
11/17/2021HVAC-R and service water piping design and insulationFran Huangenergy_progress
11/17/2021HVAC-R and service water heating equipmentFran Huangenergy_progress
11/17/2021Maintenance informationFran Huangenergy_progress
11/17/2021HVAC-R and service water heating system controlsFran Huangenergy_progress
02/24/2021Heating SystemsFran Huangspecial
Latest 25 of 28.
▾Documents — 45 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch - Plumbing4
08/25/2026X00473076-I1Request digital key ↗
08/25/2026X00473076-P2Request digital key ↗
08/25/2026X00473076-P3Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Boiler Equipment1
08/25/2026X00473080-I1Request digital key ↗
▸Seals & Professional Certifications33
▸DOB NOWProgress Inspector Seal & Signature23
09/23/2026X00473080-I1Open ↗
09/23/2026X00473080-I1Open ↗
09/23/2026X00473080-I1Open ↗
Showing 3 of 23 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/23/2026X00473080-I1Open ↗
09/01/2026X00473076-I1Open ↗
08/27/2026X00473076-P3Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/25/2026X00473076-I1Open ↗
08/25/2026X00473076-P2Open ↗
08/13/2026X00473080-I1Open ↗
Showing 3 of 5 on file for this type
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/25/2026X00473076-P2Open ↗
08/25/2026X00473076-P1Open ↗
08/25/2026X00473076-I1Open ↗
Showing 3 of 5 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026X00473080-I1Open ↗
08/13/2026X00473076-I1Open ↗