← Back
Factory, industrial, semi-fireproof
226 INDIA STREET
BROOKLYN · BIN 3064516
💬 Discuss this project
1988Year Built
1Stories
F4Building Class
M3-1Zoning
16,888 sfGross Floor Area
3Units
0 Open ViolationsFDNY Report ↗
Factory, industrial, semi-fireproof · 15,000 sf lot · 1.13 FAR built · Flood zone X500
Locations of Work
No floor-level scope or drawing coverage on file for this building.
2 jobs · most recent 06/11/2019
General Wiring
FiledStatusContractorScope
06/11/2019CompleteWILLDAN ELECTRICAL OF NYGeneral Wiring
12/14/2018CompleteWILLDAN ELECTRICAL OF NYGeneral Wiring
Building Lifecycle
All (12)Filed (3)Permit Issued (1)Signed Off (1)Violation (1)Objection (2)Special Inspection (4)
12/30/2024
Objection raised — Scope
12/30/2024
Objection raised — Cost
12/23/2024
Filed — Alteration
B01148569-I1
12/19/2024
Special inspection requirement — Final
09/03/2020
Signed off — Alteration
INSTALLATION OF NEW GAS PIPE FROM NEW METER TO THE REAR OF THE BUILDING. RAN GAS PIPE TO THE TWO (2) UNIT HEATERS AND GAS PIPE TO THE WATER HEATER. ALL THREE UNITS ARE VENTED THROUGH THE EXISTING ROOF. NEW GAS METER.
B00219849-I1
11/14/2019
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alexander Bomstein
11/14/2019
Special inspection requirement — HVAC and service water heating system controls
Alexander Bomstein
11/14/2019
Special inspection requirement — HVAC and service water heating equipment
Alexander Bomstein
11/13/2019
Filed — Alteration
INSTALLATION OF NEW GAS PIPE FROM NEW METER TO THE REAR OF THE BUILDING. RAN GAS PIPE TO THE TWO (2) UNIT HEATERS AND GAS PIPE TO THE WATER HEATER. ALL THREE UNITS ARE VENTED THROUGH THE EXISTING ROOF. NEW GAS METER.
B00219849-P1
10/23/2019
Permit issued — Plumbing
B00219849-I1-PL
09/12/2019
Filed — Alteration
INSTALLATION OF NEW GAS PIPE FROM NEW METER TO THE REAR OF THE BUILDING. RAN GAS PIPE TO THE TWO (2) UNIT HEATERS AND GAS PIPE TO THE WATER HEATER. ALL THREE UNITS ARE VENTED THROUGH THE EXISTING ROOF. NEW GAS METER.
B00219849-I1
10/16/2007
Violation issued (FDNY_NOV, closed)
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHRISTOPHER TEETER112/23/2024
DOKA ENGINEERING PC211/13/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A B WORLD CONSULTING403/21/2026
CHRISTOPHER TEETER RA203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
L&J PLG & HTG CO OF NY INPlumbing307/08/2026
STEVEN HAGGERTYElectrical203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A&B WORLD CONSULTING, INC5704211/13/2019
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offL&J PLG & HTG CO OF NY IN10/23/2019
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
12/19/2024Final—progress
11/14/2019Fire-Resistant Penetrations and JointsAlexander Bomsteinspecial
11/14/2019HVAC and service water heating system controls Alexander Bomsteinenergy_progress
11/14/2019HVAC and service water heating equipment Alexander Bomsteinenergy_progress
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch - Plumbing2
09/02/2026B00219849-I1Request digital key ↗
08/15/2026B00219849-P1Request digital key ↗
▸DOB NOWPlans/Sketch1
08/23/2026B01148569-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026B01148569-I1Open ↗
08/13/2026B00219849-I1Open ↗
08/13/2026B00219849-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/19/2026B00219849-I1Open ↗
09/19/2026B00219849-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/19/2026B00219849-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026B01148569-I1Open ↗