← Back
Five to six families
226 MOFFAT STREET
BROOKLYN · Bushwick (East) · BIN 3080170
💬 Discuss this project
1911Year Built
3Stories
C2Building Class
M1-1Zoning
4,875 sfGross Floor Area
6Units
Rent Stabilized1 Open Violation ▸FDNY Report ↗
Five to six families · Owner of record: BK 226 LLC · 2,500 sf lot · 1.95 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionCivilOther
Roof8p · 2 filings · 20 docs
Floor 359p · 5 filings · 20 docs
Floor 255p · 5 filings · 20 docs
Floor 156p · 5 filings · 20 docs
Cellar58p · 5 filings · 20 docs
Site & exterior8p · 2 filings · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
QN 483307/08/2026
BK 226 LLC1007/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/04/2022$1.2M—— → —$246/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
A.B.A STUDIO D.P.C.1204/05/2024
INFOCUS DESIGN AND PLANNING PC201/19/2023
STRUCTURAL ENGINEERING INTEGRATED101/12/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ASA BARAK STUDIO303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NY CITY CONSTRUCTION*General Contractor607/08/2026
KISHAN PLUMBING & HEATINGGeneral Contractor303/21/2026
PRIME PIPING & HEATING INFire Protection107/08/2026
ROCK E SMALL PLBG&HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ABA ARCHITECTURE8907504/05/2024
STRUCT. ENGINEERING INTEG41741404/05/2024
Building Lifecycle
All (190)Filed (15)Permit Issued (7)Signed Off (5)Violation (44)Inspection (9)Objection (80)Special Inspection (30)
04/11/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ASA BARAK
04/11/2024
Special inspection requirement — Fire-Resistance Rated Construction
Chris Yiu
04/11/2024
Special inspection requirement — Lighting in dwelling units
Chris Yiu
04/11/2024
Special inspection requirement — Interior lighting power
Chris Yiu
04/11/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Chris Yiu
04/11/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Chris Yiu
04/11/2024
Special inspection requirement — Energy Code Compliance Inspections
Chris Yiu
04/11/2024
Special inspection requirement — Lighting controls
Chris Yiu
04/11/2024
Special inspection requirement — Insulation placement and R values
Chris Yiu
04/05/2024
Filed — Alteration CO
1.PROPOSED WORK ON EXISTING CLASS A MULTIPLE DWELLING IN M1-1 ZONING. CONTINUE NON-CONFORMING USE. 2. INTERIOR RENOVATION ON ALL FLOORS3. CHANGE CONSTRUCTION CLASS TO I-C4. NO CHANGE TO BULK OR USE
B00696267-P7
04/04/2024
Special inspection requirement — Interior lighting power
Chris Yiu
04/04/2024
Special inspection requirement — Lighting controls
Chris Yiu
04/04/2024
Special inspection requirement — Insulation placement and R values
Chris Yiu
04/04/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ASA BARAK
04/04/2024
Special inspection requirement — Energy Code Compliance Inspections
Chris Yiu
04/04/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Chris Yiu
04/04/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Chris Yiu
04/04/2024
Special inspection requirement — Fire-Resistance Rated Construction
Chris Yiu
04/04/2024
Special inspection requirement — Lighting in dwelling units
Chris Yiu
03/29/2024
Filed — Alteration CO
1.PROPOSED WORK ON EXISTING CLASS A MULTIPLE DWELLING IN M1-1 ZONING. CONTINUE NON-CONFORMING USE. 2. INTERIOR RENOVATION ON ALL FLOORS3. CHANGE CONSTRUCTION CLASS TO I-C4. NO CHANGE TO BULK OR USE
B00696267-P6
03/20/2024
Signed off — Alteration
Install new sprinkler system from cellar to Bulkhead for the entire building
B00755133-I1
03/07/2024
Violation issued (HPD, closed)
A
03/07/2024
Violation issued (HPD, open)
C
03/07/2024
Violation issued (HPD, closed)
A
03/07/2024
Violation issued (HPD, closed)
A
03/07/2024
Violation issued (HPD, closed)
A
03/07/2024
Violation issued (HPD, closed)
A
03/07/2024
Violation issued (HPD, closed)
A
02/13/2024
Inspection — Fail-Final Sign Permit Inspection
Fail
View inspection ↗
11/29/2023
Filed — Alteration CO
1.PROPOSED WORK ON EXISTING CLASS A MULTIPLE DWELLING IN M1-1 ZONING. CONTINUE NON-CONFORMING USE. 2. INTERIOR RENOVATION ON ALL FLOORS3. CHANGE CONSTRUCTION CLASS TO I-C4. NO CHANGE TO BULK OR USE
B00696267-P5
11/22/2023
Special inspection requirement — Interior lighting power
Chris Yiu
11/22/2023
Special inspection requirement — Lighting in dwelling units
Chris Yiu
11/22/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
Chris Yiu
11/22/2023
Special inspection requirement — Fire-Resistance Rated Construction
Chris Yiu
11/22/2023
Special inspection requirement — Energy Code Compliance Inspections
Chris Yiu
11/22/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Chris Yiu
11/22/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ASA BARAK
11/22/2023
Special inspection requirement — Insulation placement and R values
Chris Yiu
11/22/2023
Special inspection requirement — Lighting controls
Chris Yiu
11/17/2023
Violation issued (HPD, closed)
I
10/30/2023
Signed off — Alteration
CONSTRUCTION FENCE
B08019613-I1
10/23/2023
Signed off — Alteration
NEW AC INDOOR UNITS AND OUTDOOR CONDENSERS. NEW PIPING.
B00696271-I1
10/23/2023
Permit issued — Construction Fence
B08019613-I1-FN
10/17/2023
Signed off — Alteration
NEW AND RELOCATED BATHROOM & KITCHEN FIXTURES THROUGHOUT BUILDING, NEW HOT WATER HEATERS IN EACH UNIT, REMOVE GAS & RELOCATE WATER METERS, NEW SERVICE (SEE SP FILING) & SEWER
B00696270-I1
10/10/2023
Objection raised — Other
10/10/2023
Objection resolved — Addressed
10/02/2023
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
10/02/2023
Objection raised — Fire_Protection
10/02/2023
Objection resolved — Addressed
10/02/2023
Objection raised — Zoning
10/02/2023
Objection resolved — Addressed
09/29/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
09/28/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
09/27/2023
Filed — Alteration CO
1.PROPOSED WORK ON EXISTING CLASS A MULTIPLE DWELLING IN M1-1 ZONING. CONTINUE NON-CONFORMING USE. 2. INTERIOR RENOVATION ON ALL FLOORS3. CHANGE CONSTRUCTION CLASS TO I-C4. NO CHANGE TO BULK OR USE
B00696267-P4
09/27/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
Chris Yiu
09/27/2023
Special inspection requirement — Lighting controls
Chris Yiu
09/27/2023
Special inspection requirement — Insulation placement and R values
Chris Yiu
09/26/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
09/21/2023
Signed off — Alteration
1. New stair core & surrounding floor framing repair. 2. New bulkhead & dunnage
B00696274-I1
09/21/2023
Permit issued — Sprinklers
B00755133-I1-EW-SP
Latest 60 of 190 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FenceSigned-offNY CITY CONSTRUCTION*10/23/2023
DOB NOWSprinklersSigned-offA M B MECHANICAL INC09/21/2023
DOB NOWStructuralSigned-offNY CITY CONSTRUCTION*08/25/2023
DOB NOWMechanical SystemsSigned-offNY CITY CONSTRUCTION*08/25/2023
DOB NOWGeneral ConstructionPermit IssuedNY CITY CONSTRUCTION*04/11/2023
DOB NOWPlumbingSigned-offROCK E SMALL PLBG&HTG INC03/21/2023
DOB NOWGeneral ConstructionPermit IssuedKISHAN PLUMBING & HEATING09/22/2022
1 project · most recent 07/19/2022
General Wiring
FiledStatusContractorScope
07/19/2022CompleteRONEY ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
02/13/2024Fail-Final Sign Permit InspectionFailView ↗
10/02/2023Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
09/29/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
09/28/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/26/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/14/2023Pass-Final CND-Occupancy InspectionPassView ↗
03/24/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/24/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/24/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 65
DateRequirementInspectorRole
04/11/2024Lighting in dwelling unitsChris Yiuenergy_progress
04/11/2024Insulation placement and R valuesChris Yiuenergy_progress
04/11/2024Interior lighting powerChris Yiuenergy_progress
04/11/2024Fenestration and door U-factor and product ratingsChris Yiuenergy_progress
04/11/2024Lighting controlsChris Yiuenergy_progress
04/11/2024Fire-Resistance Rated ConstructionChris Yiuprogress
04/11/2024Energy Code Compliance InspectionsChris Yiuprogress
04/11/2024Fire-Resistant Penetrations and JointsASA BARAKspecial
04/11/2024Structural Stability – Alterations of existing buildingsChris Yiuspecial
04/04/2024Fenestration and door U-factor and product ratingsChris Yiuenergy_progress
04/04/2024Insulation placement and R valuesChris Yiuenergy_progress
04/04/2024Lighting controlsChris Yiuenergy_progress
04/04/2024Lighting in dwelling unitsChris Yiuenergy_progress
04/04/2024Fire-Resistance Rated ConstructionChris Yiuprogress
04/04/2024Energy Code Compliance InspectionsChris Yiuprogress
04/04/2024Interior lighting powerChris Yiuenergy_progress
04/04/2024Structural Stability – Alterations of existing buildingsChris Yiuspecial
04/04/2024Fire-Resistant Penetrations and JointsASA BARAKspecial
11/22/2023Insulation placement and R valuesChris Yiuenergy_progress
11/22/2023Fire-Resistant Penetrations and JointsASA BARAKspecial
11/22/2023Structural Stability – Alterations of existing buildingsChris Yiuspecial
11/22/2023Energy Code Compliance InspectionsChris Yiuprogress
11/22/2023Fire-Resistance Rated ConstructionChris Yiuprogress
11/22/2023Fenestration and door U-factor and product ratingsChris Yiuenergy_progress
11/22/2023Lighting in dwelling unitsChris Yiuenergy_progress
Latest 25 of 65.
▾Documents — 152 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch15
08/28/2026B00696270-P1Request digital key ↗
08/28/2026B08019613-I1Request digital key ↗
08/28/2026B00696274-I1Request digital key ↗
Showing 3 of 15 on file for this type
▸Seals & Professional Certifications80
▸DOB NOWProgress Inspector Seal & Signature41
09/12/2026B00696267-I1Open ↗
09/12/2026B00696267-I1Open ↗
09/12/2026B00696267-I1Open ↗
Showing 3 of 41 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature24
09/12/2026B00696267-I1Open ↗
09/12/2026B00696267-I1Open ↗
09/02/2026B00696267-P5Open ↗
Showing 3 of 24 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature15
08/29/2026B00755133-I1Open ↗
08/28/2026B00696270-I1Open ↗
08/28/2026B00696271-I1Open ↗
Showing 3 of 15 on file for this type
▸Safety & Tenant Protection8
▸DOB NOWStreet Tree Checklist8
08/13/2026B00696267-P2Open ↗
08/13/2026B00696267-I1Open ↗
08/13/2026B00696267-P1Open ↗
Showing 3 of 8 on file for this type
▸Environmental & Asbestos14
▸DOB NOWDEP ACP-5: Asbestos Assessment Report14
08/28/2026B00696274-I1Open ↗
08/25/2026B00696267-P1Open ↗
08/25/2026B00696267-P2Open ↗
Showing 3 of 14 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026B00696267-I1Open ↗
▸Other Documents34
▸DOB NOWDHCR Document25
08/14/2026B00696270-I1Open ↗
08/14/2026B00696270-I1Open ↗
08/14/2026B00755133-I1Open ↗
Showing 3 of 25 on file for this type
▸DOB NOWProperty Ownership Certification8
08/25/2026B00696267-P1Open ↗
08/25/2026B00696267-P2Open ↗
08/25/2026B00696267-P7Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWFinal Survey1
08/13/2026B00696267-I1Open ↗