← Back
Two family frame
22-60 CORNAGA AVENUE
QUEENS · BIN 4300179
💬 Discuss this project
2025Year Built
—Stories
B2Building Class
R4-1Zoning
1,940 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Two family frame · Owner of record: CORNAGA PROPERTIES LLC · 2,909 sf lot · 0.67 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalFire Protection
Roof1p · 1 filing · 13 docs
Floor 23p · 2 filings · 20 docs
Floor 11p · 1 filing · 20 docs
Cellar1p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CORNAGA PROPERTIES2307/08/2026
OCEAN CONTRACTING103/22/2026
RETAINED REALTY403/21/2026
TRES CONSTRUCTION103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/05/2024$210K—— → —— not available
05/19/2017$106K—RETAINED REALTY, INC. → Private party— not available
▾Design Consultants (Architect / Engineer of Record)
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
OCEAN CONTRACTING LLCGeneral Contractor307/08/2026
WATER WORKS PIPING INCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ENGINEERING CONSULTING SE2050406/16/2026
THOMAS PETERSEN ARCHITECT7854210/31/2025
Building Lifecycle
All (68)Filed (8)Permit Issued (5)Signed Off (3)Violation (6)Inspection (8)Objection (8)Special Inspection (30)
08/27/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/09/2026
Objection resolved — Addressed
07/06/2026
Objection raised — Zoning
06/16/2026
Filed — New Building
Temporary construction fence
Q01110509-P2
06/02/2026
Special inspection requirement — Fenestration areas
PAUL MARINO
06/02/2026
Special inspection requirement — Footing and Foundation
PAUL MARINO
06/02/2026
Special inspection requirement — Structural Wood Frame
PAUL MARINO
06/02/2026
Special inspection requirement — Air barrier — testing
PAUL MARINO
06/02/2026
Special inspection requirement — Permanent certificate
PAUL MARINO
06/02/2026
Special inspection requirement — Air barrier - visual inspection
PAUL MARINO
06/02/2026
Special inspection requirement — Ventilation and air distribution system
PAUL MARINO
06/02/2026
Special inspection requirement — Fenestration air leakage
PAUL MARINO
06/02/2026
Special inspection requirement — Metering
PAUL MARINO
06/02/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
PAUL MARINO
06/02/2026
Special inspection requirement — HVAC-R and service water heating equipment
PAUL MARINO
06/02/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
PAUL MARINO
06/02/2026
Special inspection requirement — Interior lighting power
PAUL MARINO
06/02/2026
Special inspection requirement — Insulation placement and R values
PAUL MARINO
06/02/2026
Special inspection requirement — Electric vehicle service equipment requirements
PAUL MARINO
06/02/2026
Special inspection requirement — HVAC-R and service water heating system controls
PAUL MARINO
06/02/2026
Special inspection requirement — Protection of exposed foundation insulation
PAUL MARINO
06/02/2026
Special inspection requirement — Concrete - Cast-In-Place
PAUL MARINO
06/02/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
PAUL MARINO
06/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
PAUL MARINO
06/02/2026
Special inspection requirement — Mechanical Systems
PAUL MARINO
06/02/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
PAUL MARINO
06/02/2026
Special inspection requirement — Subgrade Inspections
PAUL MARINO
06/02/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
INDARDEO PARBHUNATH
06/02/2026
Special inspection requirement — Construction Utilizing CLT or SCL, Type IV
06/02/2026
Special inspection requirement — Energy Code Compliance Inspections
PAUL MARINO
06/02/2026
Special inspection requirement — Final
NAVEEN KUMAR
06/02/2026
Special inspection requirement — Fire-Resistance Rated Construction
PAUL MARINO
04/17/2026
Signed off — New Building
Temporary construction fence
Q01110509-S1
04/14/2026
Signed off — Alteration
Installation of PV System on existing rooftop. No changes to Egress or use of occupancy.
Q01307795-I1
01/30/2026
Signed off — New Building
Temporary construction fence
Q01110509-S2
01/16/2026
Inspection — Certified Sprinkler (PL)-SP-Fixtures (PL)-Finish
Certified
View inspection ↗
01/13/2026
Inspection — Certified Sprinkler (PL)-Sprinkler-Hydro
Certified
View inspection ↗
01/13/2026
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
01/13/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/17/2025
Permit issued — Solar
Q01307795-I1-SL
11/03/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
11/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
10/31/2025
Filed — Alteration
Installation of PV System on existing rooftop. No changes to Egress or use of occupancy.
Q01307795-P2
10/23/2025
Filed — Alteration
Installation of PV System on existing rooftop. No changes to Egress or use of occupancy.
Q01307795-I1
08/21/2025
Permit issued — Plumbing
Q01235421-I1-PL
08/15/2025
Violation issued (ECB, closed)
Construction
07/14/2025
Permit issued — Construction Fence
Q01110509-S1-FN
07/14/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/14/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/14/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/08/2025
Permit issued — Plumbing
Q01110509-S2-PL
07/01/2025
Filed — New Building
Temporary construction fence
Q01110509-P1
07/01/2025
Objection resolved — Addressed
07/01/2025
Objection resolved — Addressed
06/26/2025
Objection raised — Fire_Protection
06/26/2025
Objection raised — Fire_Protection
06/06/2025
Filed — Alteration
INSTALLATION OF PLUMBING FIXTURES AND PIPING FOR NEW 2-FAMILY BUILDING. FILED IN CONJUNCTION WITH NEW BUILDING, DOB NOW #Q01110509-I1.
Q01235421-I1
05/12/2025
Objection resolved — Addressed
05/09/2025
Objection raised — Plumbing
04/30/2025
Permit issued — Mechanical Systems
Q01110509-I1-GC-CX
Latest 60 of 68 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offMG BUILDERS/ANM MANAGE11/17/2025
DOB NOWPlumbingSigned-offSUPERIOR PIPING&MECH CORP08/21/2025
DOB NOWConstruction FenceSigned-offMG BUILDERS/ANM MANAGE07/14/2025
DOB NOWPlumbingSigned-offSUPERIOR PIPING&MECH CORP07/08/2025
DOB NOWMechanical SystemsPermit IssuedMG BUILDERS/ANM MANAGE04/30/2025
BISEQISSUEDTRES CONSTRUCTION LLC07/15/2016
BIS—ISSUEDTRES CONSTRUCTION LLC07/15/2016
BISEQISSUEDMARK CONTRACTING NY INC09/10/2015
1 job · most recent 06/16/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
06/16/2026Signed-offOCEAN CONTRACTING LLCHeating and Air Conditioning Systems
Heat / Cool
— 1ST &2ND Comfort Aire heat pump- Model # A-VCD36SA-1 Serial # S40Q4298044A090180073, BASEMENT Tosot mini split system model # TM18D6MO, serial # 63249929307 90,000 BTU ×3
__Junk__ xxxxxx
1 job · most recent 06/06/2025
FiledStatusContractorScope
06/06/2025——27 heads
1 job · most recent 06/16/2026
Storm Water/Sanitary
FiledStatusContractorScope
06/16/2026Signed-offWATER WORKS PIPING INCStorm, Water/Sanitary
2 jobs · most recent 10/20/2025
General Wiring
FiledStatusContractorScope
10/20/2025CompleteSAFEWAY CONSTRUCTION, INC—
05/19/2025CompleteSAFEWAY CONSTRUCTION, INCGeneral Wiring
1 job · most recent 06/16/2026
Concrete Wood
FiledStatusContractorScope
06/16/2026Signed-offOCEAN CONTRACTING LLCConcrete, Wood
1 job · most recent 06/16/2026
Fence
FiledStatusContractorScope
06/16/2026Signed-offOCEAN CONTRACTING LLCFence
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
08/27/2026Pass-Final CND-Occupancy InspectionPassView ↗
01/16/2026Certified Sprinkler (PL)-SP-Fixtures (PL)-FinishCertifiedView ↗
01/13/2026Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
01/13/2026Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
01/13/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/14/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/14/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/14/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 44
DateRequirementInspectorRole
06/02/2026Fenestration areasPAUL MARINOenergy_progress
06/02/2026Footing and FoundationPAUL MARINOprogress
06/02/2026Structural Wood FramePAUL MARINOprogress
06/02/2026Air barrier — testing PAUL MARINOenergy_progress
06/02/2026Permanent certificatePAUL MARINOenergy_progress
06/02/2026Air barrier - visual inspectionPAUL MARINOenergy_progress
06/02/2026Ventilation and air distribution systemPAUL MARINOenergy_progress
06/02/2026Fenestration air leakagePAUL MARINOenergy_progress
06/02/2026MeteringPAUL MARINOenergy_progress
06/02/2026Fenestration and door U-factor and product ratingsPAUL MARINOenergy_progress
06/02/2026HVAC-R and service water heating equipmentPAUL MARINOenergy_progress
06/02/2026HVAC-R and service water piping design and insulationPAUL MARINOenergy_progress
06/02/2026Interior lighting powerPAUL MARINOenergy_progress
06/02/2026Insulation placement and R valuesPAUL MARINOenergy_progress
06/02/2026Electric vehicle service equipment requirementsPAUL MARINOenergy_progress
06/02/2026HVAC-R and service water heating system controlsPAUL MARINOenergy_progress
06/02/2026Protection of exposed foundation insulationPAUL MARINOenergy_progress
06/02/2026Concrete - Cast-In-PlacePAUL MARINOspecial
06/02/2026Excavations - Sheeting, Shoring, and BracingPAUL MARINOspecial
06/02/2026Fire-Resistant Penetrations and JointsPAUL MARINOspecial
06/02/2026Mechanical SystemsPAUL MARINOspecial
06/02/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationPAUL MARINOspecial
06/02/2026Subgrade InspectionsPAUL MARINOspecial
06/02/2026Subsurface Investigations (Borings/Test Pits)INDARDEO PARBHUNATHspecial
06/02/2026Construction Utilizing CLT or SCL, Type IV—special
Latest 25 of 44.
▾Documents — 92 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/21/2026Q01110509-S1Request digital key ↗
08/21/2026Q01110509-P1Request digital key ↗
08/21/2026Q01110509-S2Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits9
▸BISPLAN / WORK APPROVAL APPLICATION5
12/03/2025440820685Open ↗
09/04/2025440249919Open ↗
11/20/2024440820685Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION3
08/01/2016421223250Open ↗
08/01/2016421223250Open ↗
09/08/2015440249919Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
11/20/2024440820685Open ↗
▸Zoning, Tax Lot & Property Records7
▸DOB NOWRestrictive Declaration/Easement 12
08/21/2026Q01110509-I1Open ↗
08/15/2026Q01110509-P2Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/15/2026Q01110509-P2Open ↗
08/13/2026Q01110509-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram2
08/15/2026Q01110509-P2Open ↗
08/13/2026Q01110509-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01110509-I1Open ↗
▸Seals & Professional Certifications32
▸DOB NOWProgress Inspector Seal & Signature12
09/25/2026Q01110509-P2Open ↗
09/25/2026Q01110509-P2Open ↗
09/25/2026Q01110509-P2Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/21/2026Q01110509-P2Open ↗
08/21/2026Q01110509-P1Open ↗
08/21/2026Q01110509-S2Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/25/2026Q01110509-P2Open ↗
09/25/2026Q01110509-P2Open ↗
08/26/2026Q01307795-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
11/20/2024440820685Open ↗
09/08/2015440249919Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
09/08/2015440249919Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
11/20/2024440820685Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
10/14/2015421223250Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
09/08/2015440249919Open ↗
▸Trade Schedules & Equipment2
▸BISSEWER/HOUSE CON SIGNOFF: DEP HC 0211
08/01/2016421223250Open ↗
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026Q01110509-I1Open ↗
▸Safety & Tenant Protection7
▸DOB NOWStreet Tree Checklist2
08/15/2026Q01110509-P2Open ↗
08/13/2026Q01110509-I1Open ↗
▸BISEXCAVATION OR DEMOLITION: 5-DAY NOTICE1
07/19/2016421223250Open ↗
▸BISSRO MD ANTI-HARASSMENT CHECKLIST1
08/01/2016421223250Open ↗
▸BISBPP: STREET TREES SITE PLAN1
08/06/2025440820685Open ↗
▸BISSTREET TREE CHECKLIST1
08/06/2025440820685Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q01110509-I1Open ↗
▸Environmental & Asbestos2
▸BISDEP ASBESTOS PROJECT COMPLETION FORM1
08/01/2016421223250Open ↗
▸BISRODENT CONTROL1
07/19/2016421223250Open ↗
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT2
08/15/2026Q01110509-P2Open ↗
08/13/2026Q01110509-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
09/08/2015440249919Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q01110509-I1Open ↗
▸Approvals, Objections & Sign-offs4
▸BISLETTERS - SUPPORTING DOCUMENTATION1
07/19/2016421223250Open ↗
▸BISTAP LETTER - DOM SVC : DEP-DOM1
07/19/2016421223250Open ↗
▸BISLANDMARKS APPROVAL1
07/19/2016421223250Open ↗
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01307795-I1Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT1
10/14/2015421223250Open ↗
▸BISPROJECT-SPECIFIC GL INSURANCE1
08/01/2016421223250Open ↗
▸Filing & Intake Forms5
▸BISEFILING JOB APPLICATION COVER SHEET2
11/20/2024440820685Open ↗
09/08/2015440249919Open ↗
▸BISADDITIONAL INFORMATION1
01/12/2026440820685Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
11/20/2024440820685Open ↗
▸BISEFILING COVER SHEET1
10/14/2015421223250Open ↗
▸Other Documents10
▸BISBPP - SUPPORTING DOCUMENTATION3
08/06/2025440820685Open ↗
05/29/2025440820685Open ↗
11/20/2024440820685Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/15/2026Q01110509-P2Open ↗
08/13/2026Q01110509-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/21/2026Q01110509-I1Open ↗
08/15/2026Q01110509-P2Open ↗
▸DOB NOWSite Survey: Initial2
08/15/2026Q01110509-P2Open ↗
08/13/2026Q01110509-I1Open ↗
▸BISSupporting Document: Fee Deferment1
07/29/2016421223250Open ↗