← Back
One story retail building
2266 AQUEDUCT AVENUE EAST
💬 Discuss this project
1920Year Built
1Stories
K1Building Class
R7AZoning
5,397 sfGross Floor Area
6Units
1 Open Violation ▸
One story retail building · Owner of record: BANNER WASHING MACHINE CO INC · 6,947 sf lot · 0.78 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Roof1p · 1 filing · 5 docs
Floor 16p · 2 filings · 16 docs
Cellar3p · 1 filing · 11 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BL CONSULTANT203/11/2023
A M ENGINEERING SERVICES PC101/17/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
H DESIGN STUDIO INC403/21/2026
J SIBAJA KITCHEN VENTILATION203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BENJAMIN DREBINElectrical403/21/2026
J. SIBAJA KITCHEN AND VE*General Contractor207/08/2026
DANNY RAMNARIANElectrical103/21/2026
TODARO JOSEPHElectrical103/21/2026
CJ HEATING & MECHANICAL CPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AM ENGINEERING SERVICES P7975101/17/2023
IP CONCRETE TESTING AND I6252101/10/2023
Building Lifecycle
All (25)Filed (3)Permit Issued (3)Violation (6)Inspection (1)Objection (8)Special Inspection (4)
10/29/2024
Permit issued — Mechanical Systems
X08036526-I1-MS
09/03/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/28/2023
Permit issued — Plumbing
X08045239-I1-PL
03/11/2023
Filed — Alteration
INSTALL COMMERCIAL COOKING EQUIPMENT AT 1ST FLOOR & CELLAR FOR EXISTING COMMERCIAL SPACE PER PROPOSED PLAN
X08045239-S1
03/11/2023
Special inspection requirement — Energy Code Compliance Inspections
BALDEMIRO LEON
03/11/2023
Special inspection requirement — Fire-Resistance Rated Construction
BALDEMIRO LEON
02/23/2023
Permit issued — Mechanical Systems
X08036526-I1-MS
01/19/2023
Objection raised — Zoning
01/19/2023
Objection resolved — Addressed
01/19/2023
Objection raised — Admin
01/19/2023
Objection resolved — Addressed
01/17/2023
Filed — Alteration
INSTALL NEW DUCT FOR EXISTING COMMERCIAL KITCHEN HOOD TYPE I, NO CHANGE OF USE EGRESS OR OCCUPANCY.
X08036526-I1
01/17/2023
Objection raised — Scope
01/17/2023
Objection resolved — Addressed
01/17/2023
Objection raised — Scope
01/17/2023
Objection resolved — Addressed
01/10/2023
Filed — Alteration
INSTALL COMMERCIAL COOKING EQUIPMENT AT 1ST FLOOR & CELLAR FOR EXISTING COMMERCIAL SPACE PER PROPOSED PLAN
X08045239-I1
01/10/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
INDARDEO PARBHUNATH
01/10/2023
Special inspection requirement — Energy Code Compliance Inspections
BALDEMIRO LEON
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/09/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedJ. SIBAJA KITCHEN AND VE*10/29/2024
DOB NOWPlumbingPermit IssuedCJ HEATING & MECHANICAL C04/28/2023
DOB NOWMechanical SystemsPermit IssuedJ. SIBAJA KITCHEN AND VE*02/23/2023
BISFPISSUEDMASTER FIRE SYSTEMS, INC02/16/2001
1 project · most recent 01/17/2023
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
01/17/2023Permit IssuedJ. SIBAJA KITCHEN AND VE*Ventilation Systems
Ventilation
Captiveaire DU180HFA 3,000 CFM ×1
Integrity Kitchen Supply TYPE II 3,000 CFM · Kitchen Exhaust ×1
1 project · most recent 03/11/2023
Gas Water/Sanitary
FiledStatusContractorScope
03/11/2023Permit IssuedCJ HEATING & MECHANICAL CGas, Water/Sanitary
1 project · most recent 11/15/2021
General Wiring
FiledStatusContractorScope
11/15/2021CompleteACCURATE ELEC'L CORP.General Wiring
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
09/03/2024Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
03/11/2023Energy Code Compliance InspectionsBALDEMIRO LEONprogress
03/11/2023Fire-Resistance Rated ConstructionBALDEMIRO LEONprogress
01/10/2023Fire-Resistant Penetrations and JointsINDARDEO PARBHUNATHspecial
01/10/2023Energy Code Compliance InspectionsBALDEMIRO LEONprogress
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Tamal ExpressRestaurant / Food ServiceCellar, Floor 1
Project X08045239 Alteration · Permit Entire · 01/10/2023
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/23/2026X08045239-S1Request digital key ↗
08/15/2026X08036526-I1Request digital key ↗
08/14/2026X08045239-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/23/2026X08036526-I1Open ↗
08/23/2026X08045239-I1Open ↗
08/23/2026X08045239-S1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026X08045239-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/23/2026X08045239-I1Open ↗
▸Environmental & Asbestos8
▸DOB NOWOER: Notice to Proceed3
08/13/2026X08045239-S1Open ↗
08/13/2026X08045239-I1Open ↗
08/13/2026X08036526-I1Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/23/2026X08045239-S1Open ↗
08/15/2026X08036526-I1Open ↗
08/14/2026X08045239-I1Open ↗
▸DOB NOWOER: Notice of Satisfaction2
08/13/2026X08036526-I1Open ↗
08/13/2026X08045239-S1Open ↗