← Back
Miscellaneous hospital / health care facility
2279 CONEY ISLAND AVENUE
BROOKLYN · Gravesend (East)-Homecrest · BIN 3426921
💬 Discuss this project
2011Year Built
3Stories
I9Building Class
R5Zoning
18,150 sfGross Floor Area
3Units
0 Open ViolationsFDNY Report ↗
Miscellaneous hospital / health care facility · Owner of record: JAR REAL ESTATE GROUP LLC · 9,516 sf lot · 1.91 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire ProtectionGeneral
Roof42p · 5 filings · 20 docs
Floor 351p · 5 filings · 20 docs
Floor 222p · 4 filings · 20 docs
Floor 133p · 5 filings · 20 docs
Filed — no permit issued5p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
RP1NYC2407/08/2026
JAR REAL ESTATE GROUP2307/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/30/2015$585K—Private party → Private party$32/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LEVIN ENGINEERING PLLC1803/21/2026
NEW YORK ENGINEERING ASSOCIATES P203/21/2026
AM PROFESSIONALS803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
OMNI BUILD INCGeneral Contractor1307/08/2026
ROM PIPING & HEATING INCFire Protection407/08/2026
I.D.K. ELECTRIC CO., INC.Electrical103/22/2026
MEGA PLBG CORPFire Protection107/08/2026
ROM PIPING & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
STEEL CORE ENGINEERING PL1098901/31/2025
LEVIN ENGINEERING PLLC1267710/18/2022
NEW YORK ENGINEERING ASSO851104/30/2021
Building Lifecycle
All (98)Filed (18)Permit Issued (16)Signed Off (11)Violation (7)Inspection (8)Objection (8)Special Inspection (30)
06/03/2025
Filed — Alteration
FILING to LEGALIZE EXISTING MEDICAL GAS PIPING AND STORAGE. NO CHANGE TO EGRESS, USE , OR OCCUPANCY.
B01234446-I1
06/01/2025
Special inspection requirement — Post-installed Anchors
06/01/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/07/2025
Signed off — Alteration
MECHANICAL MODIFICATIONS TO INCLUDE REPLACEMENT OF ROOFTOP UNITS, EXISTING DUCTWORK, AND AIR LUTLETS. MECHANICAL SCOPE ALSO INCLUDES NEW SPLIT AIR HANDLER SYSTEMS.
B01068697-S3
03/07/2025
Signed off — Alteration
MECANICAL MODIFICATIONS TO INCLUDE HVAC REPLACEMENT AND REPLACEMENT OF ASSOCIATED DUCTWORK. NO CHANGE TO USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION
B01062807-S1
03/05/2025
Signed off — Alteration
MECHANICAL MODIFICATIONS TO INCLUDE REPLACEMENT OF ROOFTOP UNITS, EXISTING DUCTWORK, AND AIR LUTLETS. MECHANICAL SCOPE ALSO INCLUDES NEW SPLIT AIR HANDLER SYSTEMS.
B01068697-S1
03/05/2025
Signed off — Alteration
MECHANICAL MODIFICATIONS TO INCLUDE REPLACEMENT OF ROOFTOP UNITS, EXISTING DUCTWORK, AND AIR LUTLETS. MECHANICAL SCOPE ALSO INCLUDES NEW SPLIT AIR HANDLER SYSTEMS.
B01068697-S2
02/12/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
02/11/2025
Signed off — Alteration
MECANICAL MODIFICATIONS TO INCLUDE HVAC REPLACEMENT AND REPLACEMENT OF ASSOCIATED DUCTWORK. NO CHANGE TO USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION
B01062807-I1
02/11/2025
Signed off — Alteration
MECHANICAL MODIFICATIONS TO INCLUDE REPLACEMENT OF ROOFTOP UNITS, EXISTING DUCTWORK, AND AIR LUTLETS. MECHANICAL SCOPE ALSO INCLUDES NEW SPLIT AIR HANDLER SYSTEMS.
B01068697-I1
02/11/2025
Permit issued — Mechanical Systems
B01062807-S1-MS
02/07/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
01/31/2025
Filed — Alteration
MECANICAL MODIFICATIONS TO INCLUDE HVAC REPLACEMENT AND REPLACEMENT OF ASSOCIATED DUCTWORK. NO CHANGE TO USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION
B01062807-S1
01/31/2025
Permit issued — Mechanical Systems
B01068697-S3-MS
01/30/2025
Special inspection requirement — HVAC-R and service water heating system controls
Alexander Sheyman
01/30/2025
Special inspection requirement — HVAC-R and service water heating equipment
Alexander Sheyman
01/30/2025
Special inspection requirement — Final
Alexander Sheyman
01/30/2025
Special inspection requirement — Mechanical Systems
Alexander Sheyman
01/30/2025
Special inspection requirement — Post-installed Anchors
Alexander Sheyman
01/30/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Alexander Sheyman
01/30/2025
Special inspection requirement — Duct leakage testing, insulation and design
Alexander Sheyman
01/30/2025
Special inspection requirement — Maintenance information
Alexander Sheyman
01/29/2025
Filed — Alteration
MECHANICAL MODIFICATIONS TO INCLUDE REPLACEMENT OF ROOFTOP UNITS, EXISTING DUCTWORK, AND AIR LUTLETS. MECHANICAL SCOPE ALSO INCLUDES NEW SPLIT AIR HANDLER SYSTEMS.
B01068697-S3
01/14/2025
Filed — Alteration
MECHANICAL MODIFICATIONS TO INCLUDE REPLACEMENT OF ROOFTOP UNITS, EXISTING DUCTWORK, AND AIR LUTLETS. MECHANICAL SCOPE ALSO INCLUDES NEW SPLIT AIR HANDLER SYSTEMS.
B01068697-P1
01/14/2025
Special inspection requirement — Post-installed Anchors
Alexander Sheyman
01/14/2025
Special inspection requirement — Sprinkler Systems
Alexander Sheyman
12/20/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/20/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/30/2024
Permit issued — Sprinklers
B01068697-S2-EW-SP
08/15/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/02/2024
Permit issued — Plumbing
B01068697-S1-PL
07/25/2024
Filed — Alteration
MECHANICAL MODIFICATIONS TO INCLUDE REPLACEMENT OF ROOFTOP UNITS, EXISTING DUCTWORK, AND AIR LUTLETS. MECHANICAL SCOPE ALSO INCLUDES NEW SPLIT AIR HANDLER SYSTEMS.
B01068697-S1
07/23/2024
Filed — Alteration
MECHANICAL MODIFICATIONS TO INCLUDE REPLACEMENT OF ROOFTOP UNITS, EXISTING DUCTWORK, AND AIR LUTLETS. MECHANICAL SCOPE ALSO INCLUDES NEW SPLIT AIR HANDLER SYSTEMS.
B01068697-S2
07/23/2024
Special inspection requirement — Post-installed Anchors
Alexander Sheyman
07/23/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Alexander Sheyman
07/19/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alexander Sheyman
06/24/2024
Permit issued — General Construction
B01068697-I1-GC
06/19/2024
Filed — Alteration
MECHANICAL MODIFICATIONS TO INCLUDE REPLACEMENT OF ROOFTOP UNITS, EXISTING DUCTWORK, AND AIR LUTLETS. MECHANICAL SCOPE ALSO INCLUDES NEW SPLIT AIR HANDLER SYSTEMS.
B01068697-I1
06/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alexander Sheyman
06/18/2024
Special inspection requirement — Final
Alexander Sheyman
06/11/2024
Permit issued — General Construction
B01062807-I1-GC
06/06/2024
Filed — Alteration
MECANICAL MODIFICATIONS TO INCLUDE HVAC REPLACEMENT AND REPLACEMENT OF ASSOCIATED DUCTWORK. NO CHANGE TO USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION
B01062807-I1
06/06/2024
Special inspection requirement — Final
Alexander Sheyman
06/06/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alexander Sheyman
11/29/2022
Signed off — Alteration
INSTALLATION OF MECHANICAL SYSTEM IN CONJUNCTION WITH NEW BUILDING APPLICATION # 321150801. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00281464-I1
11/01/2022
Signed off — Alteration
INSTALLATION OF MECHANICAL SYSTEM IN CONJUNCTION WITH NEW BUILDING APPLICATION # 321150801. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00281464-S1
10/28/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Dmitry Levin
10/28/2022
Special inspection requirement — Mechanical Systems
Dmitry Levin
10/28/2022
Special inspection requirement — HVAC and service water heating equipment
Dmitry Levin
10/28/2022
Special inspection requirement — HVAC and service water heating system controls
Dmitry Levin
10/28/2022
Special inspection requirement — Maintenance information
Dmitry Levin
10/28/2022
Special inspection requirement — Shutoff dampers
Dmitry Levin
10/28/2022
Special inspection requirement — Final
Dmitry Levin
10/28/2022
Special inspection requirement — Post-installed Anchors
Dmitry Levin
10/28/2022
Special inspection requirement — HVAC insulation and sealing
Dmitry Levin
10/18/2022
Filed — Alteration
INSTALLATION OF MECHANICAL SYSTEM IN CONJUNCTION WITH NEW BUILDING APPLICATION # 321150801. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00281464-P4
10/06/2022
Special inspection requirement — Post-installed Anchors
Dmitry Levin
10/06/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Dmitry Levin
09/20/2022
Filed — Alteration
INSTALLATION OF MECHANICAL SYSTEM IN CONJUNCTION WITH NEW BUILDING APPLICATION # 321150801. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00281464-P3
09/13/2021
Signed off — Alteration
B00557812-I1
Latest 60 of 98 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offOMNI BUILD INC02/11/2025
DOB NOWMechanical SystemsSigned-offOMNI BUILD INC01/31/2025
DOB NOWSprinklersSigned-offREAL PLUMBING CORP10/30/2024
DOB NOWPlumbingSigned-offM & M PIPING AND HEATING08/02/2024
DOB NOWGeneral ConstructionSigned-offOMNI BUILD INC06/24/2024
DOB NOWGeneral ConstructionSigned-offOMNI BUILD INC06/11/2024
DOB NOWSprinklersSigned-offROM PIPING & HEATING INC08/20/2021
DOB NOWBoiler EquipmentSigned-offJACK PICCINI, INC07/09/2021
DOB NOWSprinklersPermit IssuedROM PIPING & HEATING INC03/01/2021
DOB NOWMechanical SystemsSigned-offOMNI BUILD INC12/08/2020
DOB NOWMechanical SystemsSigned-offOMNI BUILD INC11/06/2020
DOB NOWSprinklersPermit IssuedROM PIPING & HEATING INC11/02/2020
DOB NOWMechanical SystemsSigned-offOMNI BUILD INC10/02/2020
DOB NOWMechanical SystemsSigned-offOMNI BUILD INC07/23/2020
DOB NOWPlumbingSigned-offROM PIPING & HTG INC01/23/2020
DOB NOWPlumbingPermit IssuedROM PIPING & HEATING INC01/13/2020
BIS—ISSUEDOMNI BUILD INC09/25/2020
BISEQISSUEDOMNI BUILD INC04/28/2020
BIS—ISSUEDOMNI BUILD INC10/29/2019
BIS—ISSUEDOMNI BUILD INC10/01/2019
BIS—ISSUEDOMNI BUILD INC05/08/2019
BISEQISSUEDOMNI BUILD INC05/08/2019
BIS—ISSUEDCHESAKL ENTERPRISES INC02/06/2019
BISEQISSUEDCHESAKL ENTERPRISES INC10/05/2018
BIS—ISSUEDCHESAKL ENTERPRISES INC10/05/2018
BISEQISSUEDB.H. CONTRACTOR INC08/22/2017
BIS—ISSUEDOMNI BUILD INC10/18/2016
BISEQISSUEDOMNI BUILD INC05/25/2016
BIS—ISSUEDOMNI BUILD INC05/25/2016
1 project · most recent 06/03/2025
Medical Gas
FiledStatusContractorScope
06/03/2025——Medical Gas
1 project · most recent 04/13/2021
General Wiring
FiledStatusContractorScope
04/13/2021CompleteI.D.K. ELECTRIC CO., INC.General Wiring
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
02/12/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/07/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
12/20/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/20/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/15/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/03/2021Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/01/2021Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
07/21/2021Pass-Final Boiler Equipment InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 59
DateRequirementInspectorRole
06/01/2025Post-installed Anchors—special
06/01/2025Fire-Resistant Penetrations and Joints—special
01/30/2025HVAC-R and service water heating system controlsAlexander Sheymanenergy_progress
01/30/2025HVAC-R and service water heating equipmentAlexander Sheymanenergy_progress
01/30/2025FinalAlexander Sheymanprogress
01/30/2025Mechanical SystemsAlexander Sheymanspecial
01/30/2025Post-installed AnchorsAlexander Sheymanspecial
01/30/2025HVAC-R and service water piping design and insulationAlexander Sheymanenergy_progress
01/30/2025Duct leakage testing, insulation and designAlexander Sheymanenergy_progress
01/30/2025Maintenance informationAlexander Sheymanenergy_progress
01/14/2025Post-installed AnchorsAlexander Sheymanspecial
01/14/2025Sprinkler SystemsAlexander Sheymanspecial
07/23/2024Post-installed AnchorsAlexander Sheymanspecial
07/23/2024HVAC-R and service water piping design and insulationAlexander Sheymanenergy_progress
07/19/2024Fire-Resistant Penetrations and JointsAlexander Sheymanspecial
06/18/2024Fire-Resistant Penetrations and JointsAlexander Sheymanspecial
06/18/2024FinalAlexander Sheymanprogress
06/06/2024FinalAlexander Sheymanprogress
06/06/2024Fire-Resistant Penetrations and JointsAlexander Sheymanspecial
10/28/2022Fire-Resistant Penetrations and JointsDmitry Levinspecial
10/28/2022Mechanical SystemsDmitry Levinspecial
10/28/2022HVAC and service water heating equipment Dmitry Levinenergy_progress
10/28/2022HVAC and service water heating system controls Dmitry Levinenergy_progress
10/28/2022Maintenance informationDmitry Levinenergy_progress
10/28/2022Shutoff dampersDmitry Levinenergy_progress
Latest 25 of 59.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Island Ambulatory | Surgery CenterMedical / HealthcareFloor 1
Project B01062807 Alteration · LOC Issued · 06/06/2024
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 188 on file (BIS + DOB NOW)
▸Plans & Drawings18
▸DOB NOWPlans/Sketch10
09/01/2026B00505436-I1Request digital key ↗
09/01/2026B00557812-I1Request digital key ↗
08/24/2026B01068697-P1Request digital key ↗
Showing 3 of 10 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems5
09/02/2026B00281464-S1Request digital key ↗
08/15/2026B00409891-P1Request digital key ↗
08/15/2026B00281464-P4Request digital key ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlans/Sketch - Plumbing3
09/02/2026B00281464-I1Request digital key ↗
08/15/2026B00281464-P2Request digital key ↗
08/15/2026B00281464-P1Request digital key ↗
▸Applications & Permits21
▸BISPLAN / WORK APPROVAL APPLICATION12
12/12/2023321150801Open ↗
10/03/2023340864782Open ↗
08/29/2023321150801Open ↗
Showing 3 of 12 on file for this type
▸BISWORK PERMIT APPLICATION6
10/29/2019321150801Open ↗
05/14/2019321150801Open ↗
05/14/2019321150801Open ↗
Showing 3 of 6 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
05/21/2016321150801Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
04/25/2023340883725Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
02/19/2021321150801Open ↗
▸Zoning, Tax Lot & Property Records9
▸BISADDRESS: NEW HOUSE NUMBER APPROVED2
10/18/2023321150801Open ↗
04/21/2016321150801Open ↗
▸BISVERIFY TAX LOT1
01/19/2024321150801Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
01/19/2024321150801Open ↗
▸BISZONING DIAGRAM1
05/09/2016321150801Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
04/21/2016321150801Open ↗
▸BISZONING RESOLUTION DETERMINATION1
08/30/2016321150801Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
04/21/2016321150801Open ↗
▸BISTAX LOT: FINAL LOT NUMBER ISSUED1
01/17/2024321150801Open ↗
▸Seals & Professional Certifications73
▸DOB NOWProgress Inspector Seal & Signature28
09/21/2026B00281464-I1Open ↗
09/21/2026B00281464-I1Open ↗
09/21/2026B00281464-I1Open ↗
Showing 3 of 28 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature18
09/02/2026B00409891-I1Open ↗
09/02/2026B00409891-P1Open ↗
09/01/2026B00505436-I1Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature16
09/21/2026B00281464-I1Open ↗
09/20/2026B00409891-P1Open ↗
09/02/2026B01062807-S1Open ↗
Showing 3 of 16 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION6
03/13/2020321150801Open ↗
06/01/2016321150801Open ↗
05/20/2016321150801Open ↗
Showing 3 of 6 on file for this type
▸BISAPPLICANT OWNER SIGNATURE2
04/06/2023340883725Open ↗
08/29/2022340864782Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
07/09/2019321971960Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
07/09/2019321971960Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
04/06/2023340883725Open ↗
▸Trade Schedules & Equipment5
▸BISSPRINKLER SYSTEMS1
10/18/2023321150801Open ↗
▸BISSPRINKLER (SP) SIGNOFF1
10/25/2023321150801Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
10/27/2023321150801Open ↗
▸BISEQUIPMENT USE PERMITS1
10/27/2023321150801Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA1
11/08/2021321150801Open ↗
▸Safety & Tenant Protection8
▸BISSTREET TREE CHECKLIST5
01/26/2024321150801Open ↗
04/21/2023340883725Open ↗
04/06/2023340883725Open ↗
Showing 3 of 5 on file for this type
▸BISSTREET TREE SUPPORTING DOCUMENT1
06/01/2016321150801Open ↗
▸BISSTREET TREE SIGNOFF1
10/18/2023321150801Open ↗
▸BISEXCAVATION OR DEMOLITION: 5-DAY NOTICE1
06/01/2016321150801Open ↗
▸Energy Compliance7
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
06/01/2016321150801Open ↗
02/20/2016321150801Open ↗
06/25/2015321150801Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
10/18/2023321150801Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
11/23/2021321150801Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
07/08/2021321150801Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026B00281464-S1Open ↗
▸Inspections & Test Reports8
▸BISTECHNICAL REPORT: RESPONSIBILITY3
01/07/2022321150801Open ↗
12/16/2021321150801Open ↗
07/08/2021321150801Open ↗
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER2
01/07/2022321150801Open ↗
06/01/2016321150801Open ↗
▸BISBORINGS / TEST PITS (TR-4) 27-7201
04/21/2016321150801Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
04/21/2016321150801Open ↗
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX1
06/01/2016321150801Open ↗
▸Approvals, Objections & Sign-offs13
▸BISLETTERS - SUPPORTING DOCUMENTATION4
04/21/2023340883725Open ↗
04/21/2023340883725Open ↗
04/06/2023340883725Open ↗
Showing 3 of 4 on file for this type
▸BISSUPERSEDING LETTER3
05/14/2019321150801Open ↗
10/09/2018321150801Open ↗
10/09/2018321150801Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE3
10/13/2015321150801Open ↗
08/21/2015321150801Open ↗
06/25/2015321150801Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
06/25/2015321150801Open ↗
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
08/03/2023340883725Open ↗
▸BISLetter from Homeowner for Withdrawal1
04/20/2016321150801Open ↗
▸Cost, Insurance & Ownership7
▸BISPROJECT-SPECIFIC GL INSURANCE4
10/29/2019321150801Open ↗
05/14/2019321150801Open ↗
10/09/2018321150801Open ↗
Showing 3 of 4 on file for this type
▸BISAcord 25 (Acord Certificate of Liability Insurance)1
10/09/2018321150801Open ↗
▸BISPROJECT SPECIFIC GENERAL LIABILITY INSURANCE1
10/09/2018321150801Open ↗
▸BISCOST AFFIDAVIT1
07/09/2019321971960Open ↗
▸Filing & Intake Forms12
▸BISADDITIONAL INFORMATION8
01/25/2024321150801Open ↗
12/15/2023321150801Open ↗
10/25/2023321150801Open ↗
Showing 3 of 8 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET2
04/06/2023340883725Open ↗
08/29/2022340864782Open ↗
▸BISEFILING COVER SHEET2
07/01/2019321971960Open ↗
06/25/2015321150801Open ↗
▸Other Documents7
▸BISPLOT DIAGRAM3
04/21/2016321150801Open ↗
03/03/2016321150801Open ↗
06/25/2015321150801Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
03/16/2016321150801Open ↗
03/16/2016321150801Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
03/06/2022321150801Open ↗
▸BISFEMA ELEVATION CERT (086-0-33)/ FLOODPROOFING CERT (086-0-34)1
10/04/2023321150801Open ↗