← Back
BuildNYC
Two family brick
23-20 33RD STREET
QUEENS · BIN 4017192
💬 Discuss this project
1901Year Built
2Stories
B1Building Class
R5BZoning
2,761 sfGross Floor Area
2Units
Two family brick · 1,625 sf lot · 1.7 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
Floor 2Under Construction5p · 1 filing · 10 docs
Floor 1Under Construction4p · 1 filing · 10 docs
CellarUnder Construction4p · 1 filing · 10 docs
Site & exteriorUnder Construction2p · 1 filing · 10 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/12/2024$1.6M—— → —$585/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SBLM Architects208/08/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
David B Nicholson RA203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TPG ContractingGeneral Contractor310/20/2026
Aqueduct MechanicalPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Vincent J. Liotta P. E1974104/23/2025
Building Lifecycle
All (10)Filed (2)Permit Issued (4)Special Inspection (4)
10/19/2026
Permit issued — Mechanical Systems
Q01213446-I1-GC-CX
11/20/2025
Permit issued — Mechanical Systems
Q01213446-I1-GC-CX
10/14/2025
Permit issued — Plumbing
Q01213446-S1-PL
09/30/2025
Special inspection requirement — HVAC-R and service water heating equipment
Vincent Liotta
09/30/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Vincent Liotta
09/30/2025
Special inspection requirement — Maintenance information
Vincent Liotta
09/30/2025
Special inspection requirement — HVAC-R and service water heating system controls
Vincent Liotta
08/14/2025
Permit issued — General Construction
Q01213446-I1-GC-CX
08/08/2025
Filed — Alteration CO
Remove, replace, and install plumbing fixtures with associated pipes on all floors, as per accompanying plans.
Q01213446-S1
04/23/2025
Filed — Alteration CO
Remove, replace, and install plumbing fixtures with associated pipes on all floors, as per accompanying plans.
Q01213446-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedTPG Contracting10/19/2026
DOB NOWMechanical SystemsPermit IssuedTPG Contracting11/20/2025
DOB NOWPlumbingPermit IssuedAqueduct Mechanical10/14/2025
DOB NOWGeneral ConstructionPermit IssuedTPG Contracting08/14/2025
BISOTISSUEDTony & Lorenzo Management05/10/2012
1 project · most recent 08/08/2025
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/08/2025Permit IssuedTPG ContractingAir Conditioning Systems
Cooling
Mitsubishi Electric PUZ-A18NKA7, SUZ-KA36NA2TH, PUZ-A24NHA7 78,000 BTU · Condensing Unit ×3
1 project · most recent 08/08/2025
Gas Water/Sanitary
FiledStatusContractorScope
08/08/2025Permit IssuedAqueduct MechanicalGas, Water/Sanitary
1 project · most recent 10/16/2025
General Wiring
FiledStatusContractorScope
10/16/2025Permit IssuedW & M ElectricGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
09/30/2025HVAC-R and service water heating equipmentVincent Liottaenergy_progress
09/30/2025HVAC-R and service water piping design and insulationVincent Liottaenergy_progress
09/30/2025Maintenance informationVincent Liottaenergy_progress
09/30/2025HVAC-R and service water heating system controlsVincent Liottaenergy_progress
▾Documents — 29 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/19/2026Q01213446-S1Request digital key ↗
08/19/2026Q01213446-I1Request digital key ↗
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
01/12/2019420539064Open ↗
03/01/2012420539064Open ↗
▸BISWORK PERMIT APPLICATION1
05/15/2012420539064Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01213446-I1Open ↗
▸Seals & Professional Certifications7
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
01/12/2019420539064Open ↗
03/01/2012420539064Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/19/2026Q01213446-S1Open ↗
08/19/2026Q01213446-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
03/01/2012420539064Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
03/01/2012420539064Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/24/2026Q01213446-S1Open ↗
▸Safety & Tenant Protection3
▸BISEXCAVATION OR DEMOLITION: 5-DAY NOTICE1
05/15/2012420539064Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
05/15/2012420539064Open ↗
▸DOB NOWStreet Tree Checklist1
08/19/2026Q01213446-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/19/2026Q01213446-S1Open ↗
08/19/2026Q01213446-I1Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
03/01/2012420539064Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY1
03/01/2012420539064Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
01/12/2019420539064Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
01/19/2019420539064Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
03/01/2012420539064Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
01/19/2019420539064Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
01/12/2019420539064Open ↗
03/01/2012420539064Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
03/01/2012420539064Open ↗
▸BISBOROUGH INTAKE FORM1
01/12/2019420539064Open ↗
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/19/2026Q01213446-I1Open ↗