← Back
One story - permanent living quarter
23-33 128 STREET
QUEENS · BIN 4480858
💬 Discuss this project
1945Year Built
1.5Stories
A2Building Class
R2AZoning
1,080 sfGross Floor Area
1Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
One story - permanent living quarter · Owner of record: KA2333 LLC · 5,261 sf lot · 0.21 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/02/2014$585K—Private party → SHEWAKI INC.$542/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AMERILAND BROOK LLC304/08/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AMERILAND BROOK LLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FASA CONTRACTING INCGeneral Contractor207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AMERILAND BROOK LLC1506204/08/2026
Building Lifecycle
All (10)Filed (3)Permit Issued (2)Inspection (1)Special Inspection (4)
07/23/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
06/03/2026
Permit issued — Construction Fence
Q01295192-S1-FN
06/03/2026
Permit issued — Full Demolition
Q01295192-I1-FD
05/26/2026
Special inspection requirement — Demolition
XIAOHONG ZHAO
05/26/2026
Special inspection requirement — Structural Stability – Alterations of existing Buildings
XIAOHONG ZHAO
04/08/2026
Filed — Full Demolition
Q01295192-P1
03/21/2026
Special inspection requirement — Demolition
XIAOHONG ZHAO
03/21/2026
Special inspection requirement — Structural Stability – Alterations of existing Buildings
XIAOHONG ZHAO
12/31/2025
Filed — Full Demolition
Q01295192-S1
11/21/2025
Filed — Full Demolition
Q01295192-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedFASA CONTRACTING INC06/03/2026
DOB NOWFull DemolitionPermit IssuedFASA CONTRACTING INC06/03/2026
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
07/23/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
05/26/2026DemolitionXIAOHONG ZHAOspecial
05/26/2026Structural Stability – Alterations of existing BuildingsXIAOHONG ZHAOspecial
03/21/2026DemolitionXIAOHONG ZHAOspecial
03/21/2026Structural Stability – Alterations of existing BuildingsXIAOHONG ZHAOspecial
▾Documents — 23 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/17/2026Q01295192-P1Request digital key ↗
08/17/2026Q01295192-S1Request digital key ↗
08/17/2026Q01295192-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWSpecial Inspector Seal & Signature4
09/22/2026Q01295192-P1Open ↗
09/22/2026Q01295192-P1Open ↗
08/28/2026Q01295192-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/17/2026Q01295192-P1Open ↗
08/17/2026Q01295192-S1Open ↗
08/17/2026Q01295192-I1Open ↗
▸Trade Schedules & Equipment4
▸DOB NOWSewer Cut-Off1
08/17/2026Q01295192-I1Open ↗
▸DOB NOWElectric Cut-Off1
08/17/2026Q01295192-I1Open ↗
▸DOB NOWGas Cut-Off1
08/17/2026Q01295192-I1Open ↗
▸DOB NOWWater Cut-Off1
08/17/2026Q01295192-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/17/2026Q01295192-I1Open ↗
08/17/2026Q01295192-P1Open ↗
▸DOB NOWRodent Control1
08/17/2026Q01295192-I1Open ↗
▸Other Documents6
▸DOB NOWProperty Ownership Certification2
08/17/2026Q01295192-P1Open ↗
08/17/2026Q01295192-I1Open ↗
▸DOB NOWStructure Photographs2
08/17/2026Q01295192-P1Open ↗
08/17/2026Q01295192-I1Open ↗
▸DOB NOWFull Demo: 10-Day Notice1
08/17/2026Q01295192-I1Open ↗
▸DOB NOWCommunity Board Notification1
08/17/2026Q01295192-I1Open ↗