← Back
Two family brick
23-44 93 STREET
QUEENS · East Elmhurst · BIN 4023629
💬 Discuss this project
1960Year Built
2Stories
B1Building Class
R3-2Zoning
2,299 sfGross Floor Area
2Units
Two family brick · 1,900 sf lot · 1.21 FAR built · Flood zone X
Locations of Work
Architecture
Floor 22p · 1 filing · 17 docs
Floor 1
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
UNGJIB PARK ARCHITECT, PC203/25/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EXPEDITE GENERAL CONTRACTGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
UNGJIB PARK ARCHITECT, PC3009203/25/2022
Building Lifecycle
All (20)Filed (2)Permit Issued (1)Signed Off (1)Inspection (2)Objection (4)Special Inspection (10)
04/01/2022
Signed off — Alteration
INSTALLATION OF TERRACE IN REAR YARD, WITH A DOOR ON 2ND FLOOR NO CHANGE IN USE, EGRESS OR OCCUPANCY
Q00538894-I1
03/31/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
03/29/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
UNG-JIB PARK
03/29/2022
Special inspection requirement — Air barrier - visual inspection
UNG-JIB PARK
03/29/2022
Special inspection requirement — Fenestration areas
UNG-JIB PARK
03/29/2022
Special inspection requirement — Fenestration air leakage
UNG-JIB PARK
03/29/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
UNG-JIB PARK
03/25/2022
Filed — Alteration
INSTALLATION OF TERRACE IN REAR YARD, WITH A DOOR ON 2ND FLOOR NO CHANGE IN USE, EGRESS OR OCCUPANCY
Q00538894-P1
03/24/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
UNG-JIB PARK
03/24/2022
Special inspection requirement — Air barrier - visual inspection
UNG-JIB PARK
03/24/2022
Special inspection requirement — Fenestration air leakage
UNG-JIB PARK
03/24/2022
Special inspection requirement — Fenestration areas
UNG-JIB PARK
03/24/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
UNG-JIB PARK
03/22/2022
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
10/29/2021
Permit issued — General Construction
Q00538894-I1-GC
07/21/2021
Objection resolved — Addressed
07/21/2021
Objection resolved — Addressed
07/15/2021
Objection raised — Other
07/15/2021
Objection raised — Other
06/14/2021
Filed — Alteration
INSTALLATION OF TERRACE IN REAR YARD, WITH A DOOR ON 2ND FLOOR NO CHANGE IN USE, EGRESS OR OCCUPANCY
Q00538894-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offEXPEDITE GENERAL CONTRACT10/29/2021
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
03/31/2022Pass-Final General Construction Non-Directive 14PassView ↗
03/22/2022Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
03/29/2022Fire-Resistant Penetrations and JointsUNG-JIB PARKspecial
03/29/2022Air barrier - visual inspectionUNG-JIB PARKenergy_progress
03/29/2022Fenestration areasUNG-JIB PARKenergy_progress
03/29/2022Fenestration air leakageUNG-JIB PARKenergy_progress
03/29/2022Fenestration and door U-factor and product ratingsUNG-JIB PARKenergy_progress
03/24/2022Fire-Resistant Penetrations and JointsUNG-JIB PARKspecial
03/24/2022Air barrier - visual inspectionUNG-JIB PARKenergy_progress
03/24/2022Fenestration air leakageUNG-JIB PARKenergy_progress
03/24/2022Fenestration areasUNG-JIB PARKenergy_progress
03/24/2022Fenestration and door U-factor and product ratingsUNG-JIB PARKenergy_progress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/26/2026Q00538894-P1Request digital key ↗
08/15/2026Q00538894-I1Request digital key ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature8
09/01/2026Q00538894-I1Open ↗
09/01/2026Q00538894-I1Open ↗
09/01/2026Q00538894-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/26/2026Q00538894-P1Open ↗
08/26/2026Q00538894-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q00538894-I1Open ↗
08/27/2026Q00538894-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/26/2026Q00538894-P1Open ↗
08/15/2026Q00538894-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00538894-I1Open ↗