← Back
Two family frame
23-57 31 STREET
QUEENS · BIN 4017174
💬 Discuss this project
1910Year Built
2Stories
B2Building Class
C4-3Zoning
1,260 sfGross Floor Area
2Units
Two family frame · Owner of record: 2468 LLC · 2,250 sf lot · 0.56 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalFire ProtectionGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction39p · 3 filings · 20 docs
Floor 6Under Construction15p · 1 filing · 20 docs
Floor 5Under Construction19p · 2 filings · 20 docs
Floor 4Under Construction16p · 1 filing · 20 docs
Floor 3Under Construction38p · 2 filings · 20 docs
Floor 2Under Construction36p · 1 filing · 20 docs
Floor 1Under Construction36p · 2 filings · 20 docs
CellarUnder Construction23p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KZ ENGINEERING, P.C606/15/2026
CNY ENGINEERING P.C212/03/2025
ANTHONY CUCICH ARCHITECT607/22/2025
SELF EMPLOYED310/18/2024
Nothing on file for this building.
Nothing on file for this building.
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
07/16/2026Pass-Final CND-Occupancy InspectionPassView ↗
02/13/2026No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
02/09/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/06/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/03/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/27/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/23/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/23/2026Pass-Final PL - UndergroundPassView ↗
10/10/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
10/10/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 52
DateRequirementInspectorRole
11/24/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationANTHONY CUCICHspecial
07/22/2025Structural Stability – Alterations of existing BuildingsANTHONY CUCICHspecial
07/22/2025DemolitionANTHONY CUCICHspecial
01/29/2025FinalANTHONY CUCICHprogress
01/29/2025Energy Code Compliance InspectionsANTHONY CUCICHprogress
01/29/2025Shutoff dampersANTHONY CUCICHenergy_progress
01/29/2025HVAC-R and service water heating system controlsANTHONY CUCICHenergy_progress
01/29/2025HVAC-R and service water heating equipmentANTHONY CUCICHenergy_progress
01/29/2025HVAC-R and service water piping design and insulationANTHONY CUCICHenergy_progress
01/29/2025Maintenance informationANTHONY CUCICHenergy_progress
01/29/2025Mechanical SystemsANTHONY CUCICHspecial
01/29/2025Heating SystemsANTHONY CUCICHspecial
10/21/2024Maintenance informationANTHONY CUCICHenergy_progress
10/18/2024Lighting controlsANTHONY CUCICHenergy_progress
10/15/2024Fire-Resistant Penetrations and JointsANTHONY CUCICHspecial
10/15/2024HVAC-R and service water heating system controlsANTHONY CUCICHenergy_progress
10/15/2024Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationANTHONY CUCICHspecial
10/15/2024HVAC-R and service water heating equipmentANTHONY CUCICHenergy_progress
10/15/2024HVAC-R and service water piping design and insulationANTHONY CUCICHenergy_progress
10/06/2024Sprinkler SystemsANTHONY CUCICHspecial
09/13/2024Wall Panels, Curtain Walls, and Veneers—special
08/02/2024Subsurface Investigations (Borings/Test Pits)ANTHONY CUCICHspecial
08/02/2024Concrete - Cast-In-PlaceANTHONY CUCICHspecial
08/02/2024Construction Operations Influencing Adjacent StructuresANTHONY CUCICHspecial
08/02/2024Designated Seismic SystemANTHONY CUCICHspecial
Latest 25 of 52.
Nothing on file for this building.