← Back
Two family frame
23 FANCHER PLACE
STATEN ISLAND · Mariner's Harbor-Arlington-Graniteville · BIN 5028546
💬 Discuss this project
1920Year Built
1.5Stories
B2Building Class
R3XZoning
1,736 sfGross Floor Area
2Units
Two family frame · 5,000 sf lot · 0.35 FAR built · Flood zone X
Locations of Work
Architecture
Roof4p · 1 filing · 12 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC203/04/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SMITSON ELECTRIC CORPElectrical103/22/2026
CENTURION SOLAR ENERGYGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854203/04/2025
Building Lifecycle
All (9)Filed (2)Permit Issued (1)Signed Off (1)Special Inspection (5)
03/06/2025
Signed off — Alteration
S01029885-I1
03/05/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
03/05/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
03/05/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
03/05/2025
Special inspection requirement — Final
TOM PETERSEN
03/05/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
03/04/2025
Filed — Alteration
S01029885-P1
05/01/2024
Permit issued — Solar
S01029885-I1-SL
04/29/2024
Filed — Alteration
S01029885-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offCENTURION SOLAR ENERGY05/01/2024
2 projects · most recent 04/21/2024
General Wiring
FiledStatusContractorScope
04/21/2024CompleteSMITSON ELECTRIC CORPGeneral Wiring
04/15/2024CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
03/05/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
03/05/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
03/05/2025Energy Code Compliance InspectionsTOM PETERSENprogress
03/05/2025FinalTOM PETERSENprogress
03/05/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026S01029885-I1Request digital key ↗
08/20/2026S01029885-P1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature3
08/25/2026S01029885-I1Open ↗
08/25/2026S01029885-I1Open ↗
08/25/2026S01029885-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026S01029885-P1Open ↗
08/20/2026S01029885-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026S01029885-I1Open ↗
08/25/2026S01029885-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/20/2026S01029885-P1Open ↗
08/20/2026S01029885-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026S01029885-I1Open ↗